메뉴 건너뛰기




Volumn 30, Issue 1, 2006, Pages 1-5

Transcranial color Doppler flow imaging in detecting severe stenosis of the intracranial vertebral artery: A prospective study

Author keywords

Intracranial vertebral artery stenosis; Transcranial color Doppler flow imaging

Indexed keywords

ANGIOCARDIOGRAPHY; DOPPLER EFFECT; HEMODYNAMICS; IMAGING TECHNIQUES; MORPHOLOGY; PATIENT MONITORING;

EID: 29244451387     PISSN: 08997071     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.clinimag.2005.07.030     Document Type: Article
Times cited : (13)

References (13)
  • 1
    • 29244489351 scopus 로고    scopus 로고
    • The prospects of transcranial ultrasonography
    • WH Jian The prospects of transcranial ultrasonography Chin J Ultrasonogr 9 1 2000 7 8
    • (2000) Chin J Ultrasonogr , vol.9 , Issue.1 , pp. 7-8
    • Jian, W.H.1
  • 2
    • 0034094087 scopus 로고    scopus 로고
    • Visualization of basilar artery by transcranial color-coded duplex sonography: Comparison with postmortem result
    • G Schulte-Altedomeburg, D Droste, and V Popa Visualization of basilar artery by transcranial color-coded duplex sonography: comparison with postmortem result Stroke 31 5 2000 1123 1127
    • (2000) Stroke , vol.31 , Issue.5 , pp. 1123-1127
    • Schulte-Altedomeburg, G.1    Droste, D.2    Popa, V.3
  • 3
    • 0036084560 scopus 로고    scopus 로고
    • Vertebrobasilar transcranial color-coded duplex ultrasonography: Improvement with echo enhancement
    • E Stolz, M Nuckel, and I Mendes Vertebrobasilar transcranial color-coded duplex ultrasonography: improvement with echo enhancement AJNR Am J Neuroradiol 23 6 2002 1051 1054
    • (2002) AJNR Am J Neuroradiol , vol.23 , Issue.6 , pp. 1051-1054
    • Stolz, E.1    Nuckel, M.2    Mendes, I.3
  • 4
    • 0001286703 scopus 로고    scopus 로고
    • Diagnostic standard for cerebrovascular diseases
    • Chinese Association of Neurology Diagnostic standard for cerebrovascular diseases Chin J Neurol 29 12 1996 379
    • (1996) Chin J Neurol , vol.29 , Issue.12 , pp. 379
    • Association Of Neurology, C.1
  • 6
    • 29244491808 scopus 로고    scopus 로고
    • 1st ed the Combined Publishing House of Beijing Medical University and Peking Union Medical University of China Beijing
    • JC Li, GH Yuan, and WY Liu Color Doppler ultrasonic diagnosis of vascular and superior organ 1st ed 1999 the Combined Publishing House of Beijing Medical University and Peking Union Medical University of China Beijing 75
    • (1999) Color Doppler Ultrasonic Diagnosis of Vascular and Superior Organ , pp. 75
    • Li, J.C.1    Yuan, G.H.2    Liu, W.Y.3
  • 7
    • 0025028925 scopus 로고
    • Chinese-White differences in the distribution of occlusive cerebrovascular disease
    • E Feldman, N Daneault, and E Kwan Chinese-White differences in the distribution of occlusive cerebrovascular disease Neurology 40 10 1990 1541 1545
    • (1990) Neurology , vol.40 , Issue.10 , pp. 1541-1545
    • Feldman, E.1    Daneault, N.2    Kwan, E.3
  • 8
    • 0031442404 scopus 로고    scopus 로고
    • Contrast-enhanced transcranial color-coded duplex sonography in ischemic cerebrovascular disease
    • RW Baumgartner, M Arnold, and F Gonner Contrast-enhanced transcranial color-coded duplex sonography in ischemic cerebrovascular disease Stroke 28 12 1997 2473 2478
    • (1997) Stroke , vol.28 , Issue.12 , pp. 2473-2478
    • Baumgartner, R.W.1    Arnold, M.2    Gonner, F.3
  • 9
    • 0028201328 scopus 로고
    • Ultrasonographic evaluation of vertebral artery to detect vertebrobasilar axis occlusion
    • K Kimura, M Yasaka, and H Moriyasu Ultrasonographic evaluation of vertebral artery to detect vertebrobasilar axis occlusion Stroke 25 1994 1006 1009
    • (1994) Stroke , vol.25 , pp. 1006-1009
    • Kimura, K.1    Yasaka, M.2    Moriyasu, H.3
  • 10
    • 2142709596 scopus 로고    scopus 로고
    • Vertebral artery occlusion in duplex color-coded ultrasonography
    • K Saito, K Kimura, and K Nagastuka Vertebral artery occlusion in duplex color-coded ultrasonography Stroke 35 5 2004 1068 1072
    • (2004) Stroke , vol.35 , Issue.5 , pp. 1068-1072
    • Saito, K.1    Kimura, K.2    Nagastuka, K.3
  • 11
    • 0032825706 scopus 로고    scopus 로고
    • Stenosis of the main artery supplying an organ: Effect of end-organ vascular compliance on the poststenotic peak systolic velocity
    • RO Bude, and JM Rubin Stenosis of the main artery supplying an organ: effect of end-organ vascular compliance on the poststenotic peak systolic velocity J Ultrasound Med 19 9 1999 603 613
    • (1999) J Ultrasound Med , vol.19 , Issue.9 , pp. 603-613
    • Bude, R.O.1    Rubin, J.M.2
  • 13
    • 0028024641 scopus 로고
    • Dynamic transcranial Doppler assessment of posterior vertebrobasilar ischemia
    • M Sturenegger Dynamic transcranial Doppler assessment of posterior vertebrobasilar ischemia Stroke 25 1994 1776 1783
    • (1994) Stroke , vol.25 , pp. 1776-1783
    • Sturenegger, M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.