메뉴 건너뛰기




Volumn 14, Issue 8, 2005, Pages 692-699

Hand-held ultrasonography in critically ill patients;Échographie portable chez les patients en état critique

Author keywords

Critical care; Diagnostic techniques and procedures; Echocardiography; Echocardiography doppler; Hand held echography

Indexed keywords

CRITICALLY ILL PATIENT; ECHOGRAPHY; HUMAN; INTENSIVE CARE UNIT; PHYSICAL EXAMINATION; PORTABLE EQUIPMENT; REVIEW; STETHOSCOPE; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; TRANSTHORACIC ECHOCARDIOGRAPHY;

EID: 29244435355     PISSN: 16240693     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.reaurg.2005.10.018     Document Type: Short Survey
Times cited : (2)

References (42)
  • 1
    • 1542359039 scopus 로고    scopus 로고
    • Échocardiographie portable:: Utile ou futile:?
    • P. Vignon Échocardiographie portable:: utile ou futile:? Arch. Mal. Cœur 96 2003 1202 1209
    • (2003) Arch. Mal. Cœur , vol.96 , pp. 1202-1209
    • Vignon, P.1
  • 2
    • 4544298817 scopus 로고    scopus 로고
    • Hand-carried ultrasound improves the bedside cardiovascular examination
    • S.L. Kobal, S. Atar, and R.J. Siegel Hand-carried ultrasound improves the bedside cardiovascular examination Chest 126 2004 693 701
    • (2004) Chest , vol.126 , pp. 693-701
    • Kobal, S.L.1    Atar, S.2    Siegel, R.J.3
  • 4
    • 0037699950 scopus 로고    scopus 로고
    • Hand-carried echocardiography in the critical care setting
    • D.M. Spevack, P.A. Tunick, and I. Kronzon Hand-carried echocardiography in the critical care setting Echocardiography 20 2003 455 461
    • (2003) Echocardiography , vol.20 , pp. 455-461
    • Spevack, D.M.1    Tunick, P.A.2    Kronzon, I.3
  • 5
    • 0035875795 scopus 로고    scopus 로고
    • How useful is hand-carried bedside echocardiography in critically ill patients?
    • G.M. Goodkin, D.M. Spevack, P.A. Tunick, and I. Kronzon How useful is hand-carried bedside echocardiography in critically ill patients? J. Am. Coll. Cardiol. 37 2001 2019 2022
    • (2001) J. Am. Coll. Cardiol. , vol.37 , pp. 2019-2022
    • Goodkin, G.M.1    Spevack, D.M.2    Tunick, P.A.3    Kronzon, I.4
  • 7
    • 1942436336 scopus 로고    scopus 로고
    • Hand-held echocardiography with Doppler capability for the assessment of critically-ill patients: Is it reliable?
    • P. Vignon, M.B.J. Frank, J. Lesage, F. Mücke, B. Fraņois, and S. Normand Hand-held echocardiography with Doppler capability for the assessment of critically-ill patients: is it reliable? Intensive Care Med. 30 2004 718 723
    • (2004) Intensive Care Med. , vol.30 , pp. 718-723
    • Vignon, P.1    Frank, M.B.J.2    Lesage, J.3    MücKe, F.4    Fraņois, B.5    Normand, S.6
  • 8
    • 0028292689 scopus 로고
    • Recommandations de la Socít́ fraņaise de cardiologie concernant la formation des ́chocardiographistes et la ŕalisation des ́chocardiogrammes
    • R. Roudaut, T. Touche, A. Cohen, B. Cormier, P. Dehant, and B. Diebold Recommandations de la Socít́ fraņaise de cardiologie concernant la formation des ́chocardiographistes et la ŕalisation des ́chocardiogrammes Arch. Mal. Cœur 87 1994 791 798
    • (1994) Arch. Mal. Cœur , vol.87 , pp. 791-798
    • Roudaut, R.1    Touche, T.2    Cohen, A.3    Cormier, B.4    Dehant, P.5    Diebold, B.6
  • 9
    • 0035875783 scopus 로고    scopus 로고
    • Physician-performed point-of-care echocardiography using a laptop platform compared with physical examination in the cardiovascular patient
    • K.T. Spencer, A.S. Anderson, A. Bhargava, A.C. Bales, M. Sorrentino, and K. Furlong Physician-performed point-of-care echocardiography using a laptop platform compared with physical examination in the cardiovascular patient J. Am. Coll. Cardiol. 37 2001 2013 2018
    • (2001) J. Am. Coll. Cardiol. , vol.37 , pp. 2013-2018
    • Spencer, K.T.1    Anderson, A.S.2    Bhargava, A.3    Bales, A.C.4    Sorrentino, M.5    Furlong, K.6
  • 10
    • 0036829391 scopus 로고    scopus 로고
    • Clinical use of cardiac ultrasound performed with a hand-carried device in patients admitted for acute cardiac care
    • M. Rugolotto, C.P. Chang, B. Hu, I. Schnittger, and D.H. Liang Clinical use of cardiac ultrasound performed with a hand-carried device in patients admitted for acute cardiac care Am. Heart J. 90 2002 1040 1042
    • (2002) Am. Heart J. , vol.90 , pp. 1040-1042
    • Rugolotto, M.1    Chang, C.P.2    Hu, B.3    Schnittger, I.4    Liang, D.H.5
  • 11
    • 0036828620 scopus 로고    scopus 로고
    • Usefulness of hand-held ultrasound device for bedside examination of left ventricular function
    • B.J. Kimura, S.A. Amundson, C.L. Willis, E.A. Gilpin, and A.N. DeMaria Usefulness of hand-held ultrasound device for bedside examination of left ventricular function Am. J. Cardiol. 90 2002 1038 1039
    • (2002) Am. J. Cardiol. , vol.90 , pp. 1038-1039
    • Kimura, B.J.1    Amundson, S.A.2    Willis, C.L.3    Gilpin, E.A.4    Demaria, A.N.5
  • 12
    • 14544283331 scopus 로고    scopus 로고
    • The value of portable ultrasound for evaluation of cardiomegaly patients presenting at the emergency department
    • S.C. Liu, W.T. Chang, C.H. Huang, T.I. Weng, H.M.A. Matthew, and W.J. Chen The value of portable ultrasound for evaluation of cardiomegaly patients presenting at the emergency department Resuscitation 64 2005 327 331
    • (2005) Resuscitation , vol.64 , pp. 327-331
    • Liu, S.C.1    Chang, W.T.2    Huang, C.H.3    Weng, T.I.4    Matthew, H.M.A.5    Chen, W.J.6
  • 13
    • 3943063652 scopus 로고    scopus 로고
    • Randomized, controlled trial of immediate versus delayed goal-directed ultrasound to identify the cause of nontraumatic hypotension in emergency department patients
    • A.E. Jones, V.S. Tayal, M. Sullivan, and J.A. Kline Randomized, controlled trial of immediate versus delayed goal-directed ultrasound to identify the cause of nontraumatic hypotension in emergency department patients Crit. Care Med. 32 2004 1703 1708
    • (2004) Crit. Care Med. , vol.32 , pp. 1703-1708
    • Jones, A.E.1    Tayal, V.S.2    Sullivan, M.3    Kline, J.A.4
  • 14
    • 33749039406 scopus 로고    scopus 로고
    • Impact of portable ultrasound used by minimally trained physicians in pre-hospital emergencies
    • B. Cholley, L. Ducros, C. Broche, P. Plaisance, and D. Payen Impact of portable ultrasound used by minimally trained physicians in pre-hospital emergencies Crit. Care Med. 32 suppl 2004 S175
    • (2004) Crit. Care Med. , vol.32 , Issue.SUPPL. , pp. 175
    • Cholley, B.1    Ducros, L.2    Broche, C.3    Plaisance, P.4    Payen, D.5
  • 16
    • 0036551207 scopus 로고    scopus 로고
    • Hand-carried cardiac ultrasound device: Recommandations regarding new technology. a report from the Echocardiography Task Force on new technology of the Nomenclature and Standards Committee of the American Society of Echocardiography
    • J.B. Seward, P.S. Douglas, R. Erbel, R.E. Kerber, I. Kronzon, and H. Rabowski Hand-carried cardiac ultrasound device: recommandations regarding new technology. A report from the Echocardiography Task Force on new technology of the Nomenclature and Standards Committee of the American Society of Echocardiography J. Am. Soc. Echocardiogr. 15 2002 369 373
    • (2002) J. Am. Soc. Echocardiogr. , vol.15 , pp. 369-373
    • Seward, J.B.1    Douglas, P.S.2    Erbel, R.3    Kerber, R.E.4    Kronzon, I.5    Rabowski, H.6
  • 17
    • 0038375995 scopus 로고    scopus 로고
    • Accuracy of hand-carried ultrasound
    • D. Liang, and I. Schnittger Accuracy of hand-carried ultrasound Echocardiography 20 2003 487 490
    • (2003) Echocardiography , vol.20 , pp. 487-490
    • Liang, D.1    Schnittger, I.2
  • 18
    • 20644452257 scopus 로고    scopus 로고
    • Hemodynamic assessment of critically ill patients using echocardiography Doppler
    • P. Vignon Hemodynamic assessment of critically ill patients using echocardiography Doppler Curr. Opin. Crit. Care 11 2005 227 234
    • (2005) Curr. Opin. Crit. Care , vol.11 , pp. 227-234
    • Vignon, P.1
  • 19
    • 0029978285 scopus 로고    scopus 로고
    • Practice guidelines for perioperative transesophageal echocardiography
    • American society of anesthesiologists and the Society of cardiovascular Anesthesiologists Task Force on Transesophageal Echocardiography
    • American society of anesthesiologists and the Society of cardiovascular Anesthesiologists Task Force on Transesophageal Echocardiography Practice guidelines for perioperative transesophageal echocardiography Anesthesiology 84 1996 986 1006
    • (1996) Anesthesiology , vol.84 , pp. 986-1006
  • 20
    • 8744306052 scopus 로고    scopus 로고
    • Transthoracic echocardiography to identify or exclude cardiac cause of shock
    • M.X. Joseph, P.J. Disney, R. Da Costa, and S.J. Hutchison Transthoracic echocardiography to identify or exclude cardiac cause of shock Chest 126 2004 1592 1597
    • (2004) Chest , vol.126 , pp. 1592-1597
    • Joseph, M.X.1    Disney, P.J.2    Da Costa, R.3    Hutchison, S.J.4
  • 21
    • 0001977415 scopus 로고    scopus 로고
    • Échocardiographie doppler et d́tresse respiratoire aiguë
    • Socít́ de Ŕanimation de Langue Fraņaise Paris Elsevier
    • P. Vignon Échocardiographie doppler et d́tresse respiratoire aiguë Actualit́s en ŕanimation et urgences 1999 Socít́ de Ŕanimation de Langue Fraņaise Paris Elsevier 241 252
    • (1999) Actualit́s en Ŕanimation et Urgences , pp. 241-252
    • Vignon, P.1
  • 24
    • 23844457936 scopus 로고    scopus 로고
    • Quantitative assessment of pleural effusion in critically ill patients by means of ultrasonography
    • P. Vignon, C. Chastagner, V. Berkane, E. Chardac, B. Fraņois, and S. Normand Quantitative assessment of pleural effusion in critically ill patients by means of ultrasonography Crit. Care Med. 33 2005 1757 1763
    • (2005) Crit. Care Med. , vol.33 , pp. 1757-1763
    • Vignon, P.1    Chastagner, C.2    Berkane, V.3    Chardac, E.4    Fraņois, B.5    Normand, S.6
  • 25
    • 0032822462 scopus 로고    scopus 로고
    • Feasibility and safety of ultrasound-guided thoracentesis in mechanically ventilated patients
    • D. Lichtenstein, J.S. Hulot, A. Rabiller, I. Tostivint, and G. Mezìre Feasibility and safety of ultrasound-guided thoracentesis in mechanically ventilated patients Intensive Care Med. 25 1999 955 958
    • (1999) Intensive Care Med. , vol.25 , pp. 955-958
    • Lichtenstein, D.1    Hulot, J.S.2    Rabiller, A.3    Tostivint, I.4    Mezìre, G.5
  • 28
    • 4444313942 scopus 로고    scopus 로고
    • Hand-held thoracic sonography for detecting post-traumatic pneumothoraces: The Extended Focused Assessment with Sonography for Trauma (EFAST)
    • A.W. Kirkpatrick, M. Sirois, K.B. Laupland, D. Liu, K. Rowan, and C.G. Ball Hand-held thoracic sonography for detecting post-traumatic pneumothoraces: the Extended Focused Assessment with Sonography for Trauma (EFAST) J. Trauma. 57 2004 288 295
    • (2004) J. Trauma. , vol.57 , pp. 288-295
    • Kirkpatrick, A.W.1    Sirois, M.2    Laupland, K.B.3    Liu, D.4    Rowan, K.5    Ball, C.G.6
  • 30
    • 0036890463 scopus 로고    scopus 로고
    • Utility of hand-carried ultrasound devices used by cardiologists with and without significant echocardiographic experience in the cardiology inpatients and outpatients settings
    • C.J. Bruce, S.C. Montgomery, K.R. Bailey, J. Tajik, and J.B. Seward Utility of hand-carried ultrasound devices used by cardiologists with and without significant echocardiographic experience in the cardiology inpatients and outpatients settings Am. J. Cardiol. 90 2002 1273 1275
    • (2002) Am. J. Cardiol. , vol.90 , pp. 1273-1275
    • Bruce, C.J.1    Montgomery, S.C.2    Bailey, K.R.3    Tajik, J.4    Seward, J.B.5
  • 31
    • 0038075515 scopus 로고    scopus 로고
    • The use of small personal ultrasound devices by internists without formal training in echocardiography
    • J.M. De Cara, R.M. Lang, R. Koch, R. Bala, J. Penzotti, and K.T. Spencer The use of small personal ultrasound devices by internists without formal training in echocardiography Eur. J. Echocardiogr. 4 2003 141 147
    • (2003) Eur. J. Echocardiogr. , vol.4 , pp. 141-147
    • De Cara, J.M.1    Lang, R.M.2    Koch, R.3    Bala, R.4    Penzotti, J.5    Spencer, K.T.6
  • 32
    • 0038075167 scopus 로고    scopus 로고
    • A hand-carried personal ultrasound device for rapid evaluation of left ventricular function: Use after limited echo training
    • K. Lemola, E. Yamada, D. Jagasia, and R.E. Kerber A hand-carried personal ultrasound device for rapid evaluation of left ventricular function: use after limited echo training Echocardiography 20 2003 309 312
    • (2003) Echocardiography , vol.20 , pp. 309-312
    • Lemola, K.1    Yamada, E.2    Jagasia, D.3    Kerber, R.E.4
  • 33
    • 0038714283 scopus 로고    scopus 로고
    • The hand-carried echocardiographic device as an aid to the physical examination
    • J.M. DeCara, R.M. Lang, and K.T. Spencer The hand-carried echocardiographic device as an aid to the physical examination Echocardiography 20 2003 477 485
    • (2003) Echocardiography , vol.20 , pp. 477-485
    • Decara, J.M.1    Lang, R.M.2    Spencer, K.T.3
  • 34
    • 0141780848 scopus 로고    scopus 로고
    • Focused training of emergency medicine residents in goal-directed echocardiography: A prospective study
    • A.E. Jones, V.S. Tayal, and J.A. Kline Focused training of emergency medicine residents in goal-directed echocardiography: a prospective study Acad. Emerg. Med. 10 2003 1054 1058
    • (2003) Acad. Emerg. Med. , vol.10 , pp. 1054-1058
    • Jones, A.E.1    Tayal, V.S.2    Kline, J.A.3
  • 36
  • 37
    • 0037699951 scopus 로고    scopus 로고
    • Can hand-carried ultrasound devices be extended for use by the noncardiology medical community?
    • W.L. Duvall, L.B. Croft, and M.E. Goldman Can hand-carried ultrasound devices be extended for use by the noncardiology medical community? Echocardiography 20 2003 471 476
    • (2003) Echocardiography , vol.20 , pp. 471-476
    • Duvall, W.L.1    Croft, L.B.2    Goldman, M.E.3
  • 39
    • 16344384096 scopus 로고    scopus 로고
    • Use of and-carried ultrasound device by critical care physicians for the diagnosis of pericardial effusions, decreased cardiac function, and left ventricular enlargement in pediatric patients
    • C.F. Spurney, C.A. Sable, J.T. Berger, and G.R. Martin Use of and-carried ultrasound device by critical care physicians for the diagnosis of pericardial effusions, decreased cardiac function, and left ventricular enlargement in pediatric patients J. Am. Soc. Echocardiogr. 18 2005 313 319
    • (2005) J. Am. Soc. Echocardiogr. , vol.18 , pp. 313-319
    • Spurney, C.F.1    Sable, C.A.2    Berger, J.T.3    Martin, G.R.4
  • 40
    • 16644391878 scopus 로고    scopus 로고
    • Bedside limited echocardiography by the emergency physician is accurate during evaluation of the critically ill patient
    • J. Pershad, S. Myers, C. Plouman, C. Rosson, K. Elam, and J. Wan Bedside limited echocardiography by the emergency physician is accurate during evaluation of the critically ill patient Pediatrics 114 2004 e667 e671
    • (2004) Pediatrics , vol.114
    • Pershad, J.1    Myers, S.2    Plouman, C.3    Rosson, C.4    Elam, K.5    Wan, J.6
  • 41
    • 20244370575 scopus 로고    scopus 로고
    • Feasibility and potential clinical utility of goal-directed transthoracic echocardiography performed by noncardiologist intensivists using a small hand-carried device (Sonoheart) in critically-ill patients
    • A.R. Manasia, H.M. Nagaraj, R.B. Kodali, L.B. Croft, J.M. Oropello, and R. Kohli-Seth Feasibility and potential clinical utility of goal-directed transthoracic echocardiography performed by noncardiologist intensivists using a small hand-carried device (Sonoheart) in critically-ill patients J. Cardiothorac. Vasc. Anesth. 19 2005 155 159
    • (2005) J. Cardiothorac. Vasc. Anesth. , vol.19 , pp. 155-159
    • Manasia, A.R.1    Nagaraj, H.M.2    Kodali, R.B.3    Croft, L.B.4    Oropello, J.M.5    Kohli-Seth, R.6
  • 42
    • 1542513549 scopus 로고    scopus 로고
    • Formation des ŕanimateurs ̀ l'́chographie cardiaque
    • P. Vignon, and P. Gúret Formation des ŕanimateurs ̀ l'́chographie cardiaque Ŕanimation 13 2004 126 130
    • (2004) Ŕanimation , vol.13 , pp. 126-130
    • Vignon, P.1    Gúret, P.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.