메뉴 건너뛰기




Volumn 252, Issue 12, 2005, Pages 1482-1486

Increased incidence of jugular valve insufficiency in patients with transient global amnesia

Author keywords

Insufficiency; Jugular vein; Transient global amnesia; Ultrasound

Indexed keywords

ADULT; AGED; ARTICLE; CLINICAL ARTICLE; CONTROLLED STUDY; DISEASE ASSOCIATION; ECHOGRAPHY; FEMALE; HUMAN; JUGULAR VALVE INSUFFICIENCY; JUGULAR VEIN; MALE; PRIORITY JOURNAL; STATISTICAL SIGNIFICANCE; TRANSIENT GLOBAL AMNESIA; VALSALVA MANEUVER; VEIN DISEASE; VEIN VALVE;

EID: 29144504921     PISSN: 03405354     EISSN: 14321459     Source Type: Journal    
DOI: 10.1007/s00415-005-0894-9     Document Type: Article
Times cited : (57)

References (21)
  • 3
    • 0031783395 scopus 로고    scopus 로고
    • Diffusion-weighted MRI characterizes the ischemic lesion in transient global amnesia
    • Ay H, Furie KL, Yamada K, Koroshetz WJ (1998) Diffusion-weighted MRI characterizes the ischemic lesion in transient global amnesia. Neurology 51:901-903
    • (1998) Neurology , vol.51 , pp. 901-903
    • Ay, H.1    Furie, K.L.2    Yamada, K.3    Koroshetz, W.J.4
  • 5
    • 0035696119 scopus 로고    scopus 로고
    • Spreading depression: A review of the clinical relevance
    • Gorji A (2001) Spreading depression: a review of the clinical relevance. Brain Res Rev 38:33-60
    • (2001) Brain Res Rev , vol.38 , pp. 33-60
    • Gorji, A.1
  • 6
    • 0023071848 scopus 로고
    • Venous valves in subclavian and internal jugular veins. Frequency, position and structure in 100 autopsy cases
    • Harmon JV, Edwards WD (1986) Venous valves in subclavian and internal jugular veins. Frequency, position and structure in 100 autopsy cases. Am J Cardiovasc Pathol 1:51-54
    • (1986) Am J Cardiovasc Pathol , vol.1 , pp. 51-54
    • Harmon, J.V.1    Edwards, W.D.2
  • 7
    • 0025311553 scopus 로고
    • The aetiology of transient global amnesia. A case-control study of 114 cases with prospective follow-up
    • Hodges JR, Warlow CP (1990) The aetiology of transient global amnesia. A case-control study of 114 cases with prospective follow-up. Brain 113:639-657
    • (1990) Brain , vol.113 , pp. 639-657
    • Hodges, J.R.1    Warlow, C.P.2
  • 8
    • 0033634798 scopus 로고    scopus 로고
    • High speed diffusion magnetic resonance imaging of ischemia and spontaneous periinfarct spreading depression after thromboembolic stroke in the rat
    • Kastrup A, Neumann-Haefelin T, Moseley ME, de Crespigny A (2000) High speed diffusion magnetic resonance imaging of ischemia and spontaneous periinfarct spreading depression after thromboembolic stroke in the rat. J Cereb Blood Flow Metab 20:1636-1647
    • (2000) J Cereb Blood Flow Metab , vol.20 , pp. 1636-1647
    • Kastrup, A.1    Neumann-Haefelin, T.2    Moseley, M.E.3    De Crespigny, A.4
  • 9
    • 0035050360 scopus 로고    scopus 로고
    • Continuing cognitive impairment after isolated transient global amnesia
    • Kessler J, Markowitsch HJ, Rudolf J, Heiss WD (2001) Continuing cognitive impairment after isolated transient global amnesia. Int J Neurosci 106:159-168
    • (2001) Int J Neurosci , vol.106 , pp. 159-168
    • Kessler, J.1    Markowitsch, H.J.2    Rudolf, J.3    Heiss, W.D.4
  • 10
    • 0032147256 scopus 로고    scopus 로고
    • Aetiology of transient global amnesia
    • Lewis SL (1998) Aetiology of transient global amnesia. Lancet 352:397-399
    • (1998) Lancet , vol.352 , pp. 397-399
    • Lewis, S.L.1
  • 11
    • 10644221259 scopus 로고    scopus 로고
    • Functional and morphological criteria of internal jugular valve insufficiency as assessed by ultrasound
    • Nedelmann M, Eicke BM, Dieterich M (2005) Functional and morphological criteria of internal jugular valve insufficiency as assessed by ultrasound. J Neuroimaging 15:70-75
    • (2005) J Neuroimaging , vol.15 , pp. 70-75
    • Nedelmann, M.1    Eicke, B.M.2    Dieterich, M.3
  • 12
    • 0022622198 scopus 로고
    • Leao's spreading depression in the hippocampus explains transient global amnesia
    • Olesen J, Joergensen MB (1986) Leao's spreading depression in the hippocampus explains transient global amnesia. Acta Neurol Scand 73:219-220
    • (1986) Acta Neurol Scand , vol.73 , pp. 219-220
    • Olesen, J.1    Joergensen, M.B.2
  • 13
    • 0032938058 scopus 로고    scopus 로고
    • A new dynamic method for detection of internal jugular valve incompetence using air contrast ultrasonography
    • Ratanakorn D, Tegeler CH, Tesh PE (1999) A new dynamic method for detection of internal jugular valve incompetence using air contrast ultrasonography. J Neuroimaging 9:10-14
    • (1999) J Neuroimaging , vol.9 , pp. 10-14
    • Ratanakorn, D.1    Tegeler, C.H.2    Tesh, P.E.3
  • 14
    • 0029926981 scopus 로고    scopus 로고
    • Duplex-derived valve closure times fail to correlate with reflux flow volumes in patients with chronic venous insufficiency
    • Rodriguez AA, Whitehead CM, McLaughlin RL, Umphrey SE, Welch HJ, O'Donnell TF (1996) Duplex-derived valve closure times fail to correlate with reflux flow volumes in patients with chronic venous insufficiency. J Vasc Surg 23:606-610
    • (1996) J Vasc Surg , vol.23 , pp. 606-610
    • Rodriguez, A.A.1    Whitehead, C.M.2    McLaughlin, R.L.3    Umphrey, S.E.4    Welch, H.J.5    O'Donnell, T.F.6
  • 15
    • 0030025832 scopus 로고    scopus 로고
    • MR detection of cortical spreading depression immediately after focal ischemia in the rat
    • Roether J, De Crespigny AJ, D'Arceuil H, Moseley ME (1996) MR detection of cortical spreading depression immediately after focal ischemia in the rat. J Cereb Blood Flow Metab 16:214-220
    • (1996) J Cereb Blood Flow Metab , vol.16 , pp. 214-220
    • Roether, J.1    De Crespigny, A.J.2    D'Arceuil, H.3    Moseley, M.E.4
  • 16
    • 0034627267 scopus 로고    scopus 로고
    • Disturbance of venous flow patterns in patients with transient global amnesia
    • Sander D, Winbek K, Etgen T, Knapp R, Klingelhöfer J, Conrad B (2000) Disturbance of venous flow patterns in patients with transient global amnesia. Lancet 356:1982-1984
    • (2000) Lancet , vol.356 , pp. 1982-1984
    • Sander, D.1    Winbek, K.2    Etgen, T.3    Knapp, R.4    Klingelhöfer, J.5    Conrad, B.6
  • 17
  • 18
    • 2642611978 scopus 로고    scopus 로고
    • Diffusion-weighted MRI in transient global amnesia: Elevated signal intensity in the left mesial temporal lobe in 7 of 10 patients
    • Strupp M, Bruening R, Hua Wu R, Deimling M, Reiser M, Brandt T (1998) Diffusion-weighted MRI in transient global amnesia: elevated signal intensity in the left mesial temporal lobe in 7 of 10 patients. Ann Neurol 43:164-170
    • (1998) Ann Neurol , vol.43 , pp. 164-170
    • Strupp, M.1    Bruening, R.2    Hua Wu, R.3    Deimling, M.4    Reiser, M.5    Brandt, T.6
  • 19
    • 2942735280 scopus 로고    scopus 로고
    • What causes transient global amnesia? New insights from DWI
    • Tong DC, Grossman M (2004) What causes transient global amnesia? New insights from DWI. Neurology 62:2154-2155
    • (2004) Neurology , vol.62 , pp. 2154-2155
    • Tong, D.C.1    Grossman, M.2
  • 20
    • 0029914198 scopus 로고    scopus 로고
    • A correlation of air plethysmography and color-flow-assisted duplex scanning in the quantification of chronic venous insufficiency
    • Weingarten MS, Czeredarczuk M, Scovell S, Branas CC, Mignogna GM, Wolferth CC (1996) A correlation of air plethysmography and color-flow-assisted duplex scanning in the quantification of chronic venous insufficiency. J Vasc Surg 24:750-754
    • (1996) J Vasc Surg , vol.24 , pp. 750-754
    • Weingarten, M.S.1    Czeredarczuk, M.2    Scovell, S.3    Branas, C.C.4    Mignogna, G.M.5    Wolferth, C.C.6
  • 21
    • 0033853432 scopus 로고    scopus 로고
    • Competence of the internal jugular vein valve is damaged by cannulation and catheterization of the internal jugular vein
    • Wu X, Studer W, Erb T, Skarvan K, Seeberger MD (2000) Competence of the internal jugular vein valve is damaged by cannulation and catheterization of the internal jugular vein. Anesthesiology 93:319-324
    • (2000) Anesthesiology , vol.93 , pp. 319-324
    • Wu, X.1    Studer, W.2    Erb, T.3    Skarvan, K.4    Seeberger, M.D.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.