-
1
-
-
4243704873
-
Development of recommendations and methods to support assessment of soil venting performance and closure
-
EPA/600/R-01/070, Office of Research and Development, Washington, D.C
-
DiGiulio, D. C., and R. Varadhan, 2001, Development of recommendations and methods to support assessment of soil venting performance and closure, EPA/600/R-01/070, Office of Research and Development, Washington, D.C., 435 p.
-
(2001)
, pp. 435
-
-
DiGiulio, D.C.1
Varadhan, R.2
-
2
-
-
0004225608
-
Groundwater and wells
-
Minnesota, Johnson Filtration Systems Inc
-
Driscoll, F. G., 1986, Groundwater and wells: Minnesota, Johnson Filtration Systems Inc., 1089 p.
-
(1986)
, pp. 1089
-
-
Driscoll, F.G.1
-
4
-
-
84861353963
-
Volatile organic compounds in soils and other solid matrices using equilibrium headspace analysis, method 5021
-
Washington Environmental Protection Agency
-
Environmental Protection Agency, 1996, Volatile organic compounds in soils and other solid matrices using equilibrium headspace analysis, method 5021: Washington, 13 p.
-
(1996)
, pp. 13
-
-
-
5
-
-
2442504504
-
Vadose zone characterization and monitoring current technologies, applications, and future developments
-
B. Looney and R. Falta, eds., Columbus, Ohio, Battelle Press
-
Faybishenko, B., 2000, Vadose zone characterization and monitoring current technologies, applications, and future developments, in B. Looney and R. Falta, eds., Vadose zone science and technology solutions: Columbus, Ohio, Battelle Press, p. 113-510.
-
(2000)
Vadose Zone Science and Technology Solutions
, pp. 113-510
-
-
Faybishenko, B.1
-
6
-
-
0004069777
-
Cone penetration testing in geotechnical practice
-
Abington, United Kingdom, Spon Press
-
Lunne, T., P. K. Robertson, and J. J. M. Powell, 1997, Cone penetration testing in geotechnical practice: Abington, United Kingdom, Spon Press, 312 p.
-
(1997)
, pp. 312
-
-
Lunne, T.1
Robertson, P.K.2
Powell, J.J.M.3
-
7
-
-
0028396928
-
Estimating air conductivity and porosity from vadose zone pumping tests
-
Massman, J., and M. Madden, 1994, Estimating air conductivity and porosity from vadose zone pumping tests: Journal of Environmental Engineering, American Society of Civil Engineers, v. 120, no. 2, p. 313-327.
-
(1994)
Journal of Environmental Engineering, American Society of Civil Engineers
, vol.120
, Issue.2
, pp. 313-327
-
-
Massman, J.1
Madden, M.2
-
8
-
-
29144503037
-
Characterization of shallow groundwater at TNX (U), WSRC-TR-92-508
-
Westinghouse Savannah River Company, Savannah River Site, Aiken, South Carolina 29808 (accessed August 4, 2005)
-
Nichols, R. L., 1993, Characterization of shallow groundwater at TNX (U), WSRC-TR-92-508: Westinghouse Savannah River Company, Savannah River Site, Aiken, South Carolina 29808, 180 p.: http://www.osti.gov/bridge/ (accessed August 4, 2005).
-
(1993)
, pp. 180
-
-
Nichols, R.L.1
-
9
-
-
29144503144
-
TNX Area soil vapor extraction test treatability study report (U)
-
WSRC-TR-97-0336, Westinghouse Savannah River Company, Savannah River Site, Aiken, South Carolina 29808, (accessed August 4, 2005)
-
Nichols, R. L., 1997, TNX Area soil vapor extraction test treatability study report (U), WSRC-TR-97-0336, Westinghouse Savannah River Company, Savannah River Site, Aiken, South Carolina 29808, 19 p.: http:// www.osti.gov/bridge/ (accessed August 4, 2005).
-
(1997)
, pp. 19
-
-
Nichols, R.L.1
-
10
-
-
29144487053
-
TNX vadose zone characterization for the installation of soil vapor extraction wells
-
WSRC-TR-2001-00596, Westinghouse Savannah River Company, Savannah River Site, Aiken, South Carolina 29808 (accessed August 4, 2005)
-
Nichols, R. L., and J. V. Noonkester, 2001, TNX vadose zone characterization for the installation of soil vapor extraction wells, WSRC-TR-2001-00596, Westinghouse Savannah River Company, Savannah River Site, Aiken, South Carolina 29808, 27 p.: http://www.osti.gov/bridge/ (accessed August 4, 2005).
-
(2001)
, pp. 27
-
-
Nichols, R.L.1
Noonkester, J.V.2
-
11
-
-
29144473635
-
TNX soil vapor extraction multiphase model summary (U)
-
WSRC-TR-2000-00291, Westinghouse Savannah River Company, Savannah River Site, Aiken, South Carolina, (accessed 18 August 4, 2005)
-
Rossabi, J., 2000, TNX soil vapor extraction multiphase model summary (U), WSRC-TR-2000-00291, Westinghouse Savannah River Company, Savannah River Site, Aiken, South Carolina, 18 p.: http://www.osti.gov/bridge/ (accessed August 4, 2005).
-
(2000)
-
-
Rossabi, J.1
-
12
-
-
29144442026
-
Interim action record of decision remedial action alternative - TNX Area groundwater operable unit (U)
-
Westinghouse Savannah River Company, WSRC-TR-94-0375, Westinghouse Savannah River Company, Savannah River Site, Aiken, South Carolina 29808, (accessed August 4, 2005)
-
Westinghouse Savannah River Company, 1994, Interim action record of decision remedial action alternative - TNX Area groundwater operable unit (U), WSRC-TR-94-0375, Westinghouse Savannah River Company, Savannah River Site, Aiken, South Carolina 29808, 43 p.: http://www.osti.gov/ bridge/ (accessed August 4, 2005).
-
(1994)
, pp. 43
-
-
-
13
-
-
29144460100
-
TNX Area phase II soil vapor extraction test treatability study report (U)
-
Westinghouse Savannah River Company, WSRC-TR-99-00051, Westinghouse Savannah River Company, Savannah River Site, Aiken, South Carolina 29808, (accessed August 4, 2005)
-
Westinghouse Savannah River Company, 1999, TNX Area phase II soil vapor extraction test treatability study report (U), WSRC-TR-99-00051, Westinghouse Savannah River Company, Savannah River Site, Aiken, South Carolina 29808, 33 p.: http://www.osti.gov/bridge/ (accessed August 4, 2005).
-
(1999)
, pp. 33
-
-
-
14
-
-
29144446120
-
Explanation of significant differences to the revision 1 Interim Record of Decision for the TNX Area operable unit groundwater (U)
-
Westinghouse Savannah River Company, WSRC-RP-2001-00764, Westinghouse Savannah River Company, Savannah River Site, Aiken, South Carolina 29808, (accessed August 4, 2005)
-
Westinghouse Savannah River Company, 2001, Explanation of significant differences to the revision 1 Interim Record of Decision for the TNX Area operable unit groundwater (U), WSRC-RP-2001-00764, Westinghouse Savannah River Company, Savannah River Site, Aiken, South Carolina 29808, 16 p.: http://www.osti.gov/bridge/ (accessed August 4, 2005).
-
(2001)
, pp. 16
-
-
-
15
-
-
29144478666
-
Guidance for design, installation and operation of soil venting systems
-
Wisconsin Department of Natural Resources, Madison, Wisconsin, publication number PUBL-SW185-93
-
Wisconsin Department of Natural Resources, 1993, Guidance for design, installation and operation of soil venting systems: Madison, Wisconsin, publication number PUBL-SW185-93, 55 p.
-
(1993)
, pp. 55
-
-
-
16
-
-
11144262328
-
Overview of the history and geology of the Savannah River Site
-
Wyatt, D. E., and M. K. Harris, 2004, Overview of the history and geology of the Savannah River Site: AAPG Environmental Geosciences, v. 11, no. 4, p. 181-190.
-
(2004)
AAPG Environmental Geosciences
, vol.11
, Issue.4
, pp. 181-190
-
-
Wyatt, D.E.1
Harris, M.K.2
|