메뉴 건너뛰기




Volumn 42, Issue 6, 2005, Pages 1169-1175

Computational investigations of a new prosthetic femoral-popliteal bypass graft design

Author keywords

[No Author keywords available]

Indexed keywords

ARTERY PROSTHESIS; ARTICLE; COMPARATIVE STUDY; COMPUTER AIDED DESIGN; DEVICE; END TO END ANASTOMOSIS; FEMORAL ARTERY FLOW; FEMOROPOPLITEAL BYPASS; FLOW RATE; PRIORITY JOURNAL; PROCESS DESIGN; QUALITATIVE ANALYSIS; SHEAR STRESS; VASCULAR PATENCY;

EID: 29144471301     PISSN: 07415214     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jvs.2005.08.016     Document Type: Article
Times cited : (14)

References (23)
  • 2
    • 22144473728 scopus 로고    scopus 로고
    • End-to-end versus end-to-side distal anastomosis in femoropopliteal bypasses; Results of a randomised multicenter trial
    • O. Schouten, M.T.C. Hoedt, C.H.A. Wittens, W.C.J. Hop, M.R. van Sambeek, H. van Urk End-to-end versus end-to-side distal anastomosis in femoropopliteal bypasses; results of a randomised multicenter trial Eur J Vasc Endovasc Surg 29 2005 457 462
    • (2005) Eur J Vasc Endovasc Surg , vol.29 , pp. 457-462
    • Schouten, O.1    Hoedt, M.T.C.2    Wittens, C.H.A.3    Hop, W.C.J.4    Van Sambeek, M.R.5    Van Urk, H.6
  • 3
    • 0033203168 scopus 로고    scopus 로고
    • Factors influencing patency of infrainguinal bypasses with polytetrafluoroethylene
    • B. Thomas, H. Lacroix, A. Nevelsteen, R. Suy Factors influencing patency of infrainguinal bypasses with polytetrafluoroethylene Acta Chir Belg 99 1999 236 240
    • (1999) Acta Chir Belg , vol.99 , pp. 236-240
    • Thomas, B.1    Lacroix, H.2    Nevelsteen, A.3    Suy, R.4
  • 4
    • 0034193634 scopus 로고    scopus 로고
    • Above-knee prosthetic femoropopliteal bypass for intermittent claudication. Results of the initial and secondary procedures
    • S. Aune, E. Laxdal Above-knee prosthetic femoropopliteal bypass for intermittent claudication. Results of the initial and secondary procedures Eur J Vasc Endovasc Surg 19 2000 476 480
    • (2000) Eur J Vasc Endovasc Surg , vol.19 , pp. 476-480
    • Aune, S.1    Laxdal, E.2
  • 5
    • 0036182407 scopus 로고    scopus 로고
    • Relative contribution of wall shear stress and injury in experimental intimal thickening at PTFE end-to-side arterial anastomoses
    • F. Loth, S.A. Jones, C.K. Zarins, D.P. Giddens, R.F. Nassar, S. Glagov Relative contribution of wall shear stress and injury in experimental intimal thickening at PTFE end-to-side arterial anastomoses J Biomech Eng 124 2002 44 51
    • (2002) J Biomech Eng , vol.124 , pp. 44-51
    • Loth, F.1    Jones, S.A.2    Zarins, C.K.3    Giddens, D.P.4    Nassar, R.F.5    Glagov, S.6
  • 6
    • 17444380873 scopus 로고    scopus 로고
    • On reducing abnormal hemodynamics in the femoral end-to-side anastomosis: The influence of mechanical factors
    • T. O'Brien, M. Walsh, T. McGloughlin On reducing abnormal hemodynamics in the femoral end-to-side anastomosis the influence of mechanical factors Ann Biomed Eng 33 2005 309 321
    • (2005) Ann Biomed Eng , vol.33 , pp. 309-321
    • O'Brien, T.1    Walsh, M.2    McGloughlin, T.3
  • 7
    • 0026531896 scopus 로고
    • Improved technique for polytetrafluoroethylene bypass grafting: Long-term results using anastomotic vein patches
    • R.S. Taylor, A. Loh, R.J. McFarland, M. Cox, J.F. Chester Improved technique for polytetrafluoroethylene bypass grafting long-term results using anastomotic vein patches Br J Surg 79 1992 348 354
    • (1992) Br J Surg , vol.79 , pp. 348-354
    • Taylor, R.S.1    Loh, A.2    McFarland, R.J.3    Cox, M.4    Chester, J.F.5
  • 8
    • 0030729352 scopus 로고    scopus 로고
    • Randomised trial comparing infrainguinal polytetrafluoroethylene bypass grafting with and without vein interposition cuff at the distal anastomosis
    • P.A. Stonebridge, R.J. Prescott, C.V. Ruckley Randomised trial comparing infrainguinal polytetrafluoroethylene bypass grafting with and without vein interposition cuff at the distal anastomosis J Vasc Surg 26 1997 543 550
    • (1997) J Vasc Surg , vol.26 , pp. 543-550
    • Stonebridge, P.A.1    Prescott, R.J.2    Ruckley, C.V.3
  • 10
    • 0344305389 scopus 로고    scopus 로고
    • Particle hemodynamics analysis of Miller cuff arterial anastomosis
    • P. Worth Longest, C. Kleinstreuer, J.P. Archie Particle hemodynamics analysis of Miller cuff arterial anastomosis J Vasc Surg 38 2003 1353 1362
    • (2003) J Vasc Surg , vol.38 , pp. 1353-1362
    • Worth Longest, P.1    Kleinstreuer, C.2    Archie, J.P.3
  • 11
    • 0344034225 scopus 로고    scopus 로고
    • On the existence of an optimum end-to-side junctional geometry in peripheral bypass surgery - A computer generated study
    • M.T. Walsh, E.G. Kavanagh, T. O'Brien, P.A. Grace, T. McGloughlin On the existence of an optimum end-to-side junctional geometry in peripheral bypass surgery - a computer generated study Eur J Vasc Endovasc Surg 26 2003 649 656
    • (2003) Eur J Vasc Endovasc Surg , vol.26 , pp. 649-656
    • Walsh, M.T.1    Kavanagh, E.G.2    O'Brien, T.3    Grace, P.A.4    McGloughlin, T.5
  • 12
  • 15
    • 25444463634 scopus 로고    scopus 로고
    • That hemodynamics and not material mismatch is of primary concern in bypass graft failure: An experimental argument
    • T. O'Brien, L. Morris, M. Walsh, T. McGloughlin That hemodynamics and not material mismatch is of primary concern in bypass graft failure an experimental argument J Biomech Eng 127 2005 881 886
    • (2005) J Biomech Eng , vol.127 , pp. 881-886
    • O'Brien, T.1    Morris, L.2    Walsh, M.3    McGloughlin, T.4
  • 16
    • 0030220786 scopus 로고    scopus 로고
    • Numerical investigation of steady flow in proximal and distal end-to-side anastomoses
    • F.S. Henry, M.W. Collins, P.E. Hughes, T.V. How Numerical investigation of steady flow in proximal and distal end-to-side anastomoses J Biomech Eng 118 1996 302 310
    • (1996) J Biomech Eng , vol.118 , pp. 302-310
    • Henry, F.S.1    Collins, M.W.2    Hughes, P.E.3    How, T.V.4
  • 17
    • 0030890266 scopus 로고    scopus 로고
    • Computational design of a bypass graft that minimises wall shear stress gradients in the region of the distal anastomosis
    • M. Lei, J.P. Archie, C. Kleinstreuer Computational design of a bypass graft that minimises wall shear stress gradients in the region of the distal anastomosis J Vasc Surg 25 1997 637 646
    • (1997) J Vasc Surg , vol.25 , pp. 637-646
    • Lei, M.1    Archie, J.P.2    Kleinstreuer, C.3
  • 18
    • 0034959156 scopus 로고    scopus 로고
    • The effect of proximal artery flow on the hemodynamics at the distal anastomosis of a vascular bypass graft: Computational study
    • S.M. Kute, D.A. Vorp The effect of proximal artery flow on the hemodynamics at the distal anastomosis of a vascular bypass graft computational study J Biomech Eng 123 2001 277 283
    • (2001) J Biomech Eng , vol.123 , pp. 277-283
    • Kute, S.M.1    Vorp, D.A.2
  • 20
    • 0036138584 scopus 로고    scopus 로고
    • Numerical study of hemodynamics and wall mechanics in distal end-to-side anastomoses of bypass grafts
    • A. Leuprecht, K. Perktold, M. Prosi, T. Berk, W. Trubel, H. Schima Numerical study of hemodynamics and wall mechanics in distal end-to-side anastomoses of bypass grafts J Biomech 35 2002 225 236
    • (2002) J Biomech , vol.35 , pp. 225-236
    • Leuprecht, A.1    Perktold, K.2    Prosi, M.3    Berk, T.4    Trubel, W.5    Schima, H.6
  • 21
    • 0042200767 scopus 로고    scopus 로고
    • Compliance mismatch may promote graft-artery intimal hyperplasia by altering suture-line stresses
    • P.D. Ballyk, C. Walsh, J. Butany, M. Ojha Compliance mismatch may promote graft-artery intimal hyperplasia by altering suture-line stresses J Biomech 31 1998 229 237
    • (1998) J Biomech , vol.31 , pp. 229-237
    • Ballyk, P.D.1    Walsh, C.2    Butany, J.3    Ojha, M.4
  • 22
    • 0032417313 scopus 로고    scopus 로고
    • Vein patching reduces neointimal thickening associated with prosthetic graft implantation
    • A.T. Gentile, J.L. Mills, M.A. Gooden, R.D. Hagerty, S.S. Berman, J.D. Hughes Vein patching reduces neointimal thickening associated with prosthetic graft implantation Am J Surg 176 1998 601 607
    • (1998) Am J Surg , vol.176 , pp. 601-607
    • Gentile, A.T.1    Mills, J.L.2    Gooden, M.A.3    Hagerty, R.D.4    Berman, S.S.5    Hughes, J.D.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.