메뉴 건너뛰기




Volumn 52, Issue 5 I, 2005, Pages 1386-1390

Comparison of noise equivalent count rates and image noise

Author keywords

Data processing; Image analysis; Positron emission tomography

Indexed keywords

IMAGE NOISE; IMAGE SETS; NOISE EQUIVALENT COUNT (NEC); VARIANCE REDUCTION;

EID: 29144468975     PISSN: 00189499     EISSN: None     Source Type: Journal    
DOI: 10.1109/TNS.2005.858176     Document Type: Article
Times cited : (25)

References (11)
  • 1
    • 0025414253 scopus 로고
    • Measuring PET scanner sensitivity: Relating countrates to image signal-to-noise ratios using noise equivalent counts
    • S. C. Strother, M. E. Casey, and E. J. Hoffman, "Measuring PET scanner sensitivity: relating countrates to image signal-to-noise ratios using noise equivalent counts," IEEE Trans. Nucl. Sci., vol. NS-37, pp. 783-788, 1990.
    • (1990) IEEE Trans. Nucl. Sci. , vol.NS-37 , pp. 783-788
    • Strother, S.C.1    Casey, M.E.2    Hoffman, E.J.3
  • 4
    • 0001171133 scopus 로고    scopus 로고
    • Performance evaluation of the whole-body PET scanner ECAT EXACT HR+ following the IEC standard
    • L.-E. Adam, J. Zaers, H. Ostertag, H. Trojan, M. E. Belleman, and G. Brix, "Performance evaluation of the whole-body PET scanner ECAT EXACT HR+ following the IEC standard," IEEE Trans. Nucl. Sci., vol. NS-44, pp. 1172-1179, 1997.
    • (1997) IEEE Trans. Nucl. Sci. , vol.NS-44 , pp. 1172-1179
    • Adam, L.-E.1    Zaers, J.2    Ostertag, H.3    Trojan, H.4    Belleman, M.E.5    Brix, G.6
  • 6
    • 0035555123 scopus 로고    scopus 로고
    • A bootstrap approach for analyzing the statistical properties of SPECT and PET images
    • San Diego, CA
    • I. Buvat and C. Riddell, "A bootstrap approach for analyzing the statistical properties of SPECT and PET images," in Nuclear Science Symp. Medical Imaging Conf., San Diego, CA, 2001.
    • (2001) Nuclear Science Symp. Medical Imaging Conf.
    • Buvat, I.1    Riddell, C.2
  • 7
    • 0036816162 scopus 로고    scopus 로고
    • Estimation of image noise in PET using the bootstrap method
    • M. Dahlbom, "Estimation of image noise in PET using the bootstrap method," IEEE Trans. Nucl. Sci., vol. 49, pp. 2062-2066, 2002.
    • (2002) IEEE Trans. Nucl. Sci. , vol.49 , pp. 2062-2066
    • Dahlbom, M.1
  • 8
    • 0022888626 scopus 로고
    • Quantitation in positron emission computed tomography: 7. A technique to reduce noise in accidental coincidence measurements and coincidence efficiency calibration
    • M. E. Casey and E. J. Hoffman, "Quantitation in positron emission computed tomography: 7. A technique to reduce noise in accidental coincidence measurements and coincidence efficiency calibration," J. Comput. Assist. Tomogr., vol. 10, pp. 845-850, 1986.
    • (1986) J. Comput. Assist. Tomogr. , vol.10 , pp. 845-850
    • Casey, M.E.1    Hoffman, E.J.2
  • 9
    • 0021151702 scopus 로고
    • A new fast algorithm for the evaluation of regions of interest and statistical uncertainty in computed tomography
    • R. H. Huesman, "A new fast algorithm for the evaluation of regions of interest and statistical uncertainty in computed tomography," Phys. Med. Biol., vol. 29, pp. 543-552, 1984.
    • (1984) Phys. Med. Biol. , vol.29 , pp. 543-552
    • Huesman, R.H.1
  • 10
    • 8344228611 scopus 로고    scopus 로고
    • Count rate dependence of local signal-to-noise ratio in positron emission tomography
    • C. C. Watson, "Count rate dependence of local signal-to-noise ratio in positron emission tomography," IEEE Trans. Nucl. Sci, vol. NS-51, pp. 2670-2680, 2004.
    • (2004) IEEE Trans. Nucl. Sci , vol.NS-51 , pp. 2670-2680
    • Watson, C.C.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.