메뉴 건너뛰기




Volumn 125, Issue 2, 2006, Pages 124-132

Fiber-optic liquid-level continuous gauge

Author keywords

Electrical engineering and optics engineering; Fiber optics; Liquid level gauge; Optoelectronics

Indexed keywords

CONTINUOUS MEASUREMENT; ELECTRICAL ENGINEERING AND OPTICS ENGINEERING; INTERNAL REFLECTION; LIQUID-LEVEL GAUGE; POWER ATTENUATION;

EID: 29144466699     PISSN: 09244247     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.sna.2005.07.019     Document Type: Review
Times cited : (58)

References (17)
  • 5
    • 0942278999 scopus 로고    scopus 로고
    • A novel liquid level detection method and its implementation
    • A. Musayev, and S.E. Karlik A novel liquid level detection method and its implementation Sens. Actuators A 109 2003 21 24
    • (2003) Sens. Actuators A , vol.109 , pp. 21-24
    • Musayev, A.1    Karlik, S.E.2
  • 6
    • 29144536674 scopus 로고
    • Device for producing a light signal corresponding to the refractive index of a fluid, US Patent US4187025
    • A.L. Harmer, Device for producing a light signal corresponding to the refractive index of a fluid, US Patent US4187025 (1980).
    • (1980)
    • Harmer, A.L.1
  • 8
    • 84975664152 scopus 로고
    • Liquid-level sensor with optical fibers
    • K. Iwamoto, and I. Kamata Liquid-level sensor with optical fibers Appl. Opt. 31 1992 51 54
    • (1992) Appl. Opt. , vol.31 , pp. 51-54
    • Iwamoto, K.1    Kamata, I.2
  • 9
    • 0033690934 scopus 로고    scopus 로고
    • Package design for low-cost optical liquid-level sensors
    • A.K. Ghosh, N.S. Bedi, and P. Paul Package design for low-cost optical liquid-level sensors Opt. Eng. 39 2000 1405 1412
    • (2000) Opt. Eng. , vol.39 , pp. 1405-1412
    • Ghosh, A.K.1    Bedi, N.S.2    Paul, P.3
  • 10
    • 0034247940 scopus 로고    scopus 로고
    • Fluorescent optical liquid-level sensor
    • J.D. Weiss Fluorescent optical liquid-level sensor Opt. Eng. 39 2000 2198 2213
    • (2000) Opt. Eng. , vol.39 , pp. 2198-2213
    • Weiss, J.D.1
  • 11
    • 0034301139 scopus 로고    scopus 로고
    • Self-aligning, bipolar bend transducer based on long period grating written in eccentric core fibre
    • H.J. Patrick Self-aligning, bipolar bend transducer based on long period grating written in eccentric core fibre Electron. Lett. 36 2000 1763 1764
    • (2000) Electron. Lett. , vol.36 , pp. 1763-1764
    • Patrick, H.J.1
  • 12
    • 0001047283 scopus 로고    scopus 로고
    • Fiber-optic liquid-level sensor using a long-period grating
    • S. Khaliq, S.W. James, and R.P. Tatam Fiber-optic liquid-level sensor using a long-period grating Opt. Lett. 26 2001 1224 1226
    • (2001) Opt. Lett. , vol.26 , pp. 1224-1226
    • Khaliq, S.1    James, S.W.2    Tatam, R.P.3
  • 13
    • 0346154851 scopus 로고    scopus 로고
    • Design and operation of a fiber optic sensor for liquid level detection
    • H. Golnabi Design and operation of a fiber optic sensor for liquid level detection Opt. Laser Eng. 41 2004 801 812
    • (2004) Opt. Laser Eng. , vol.41 , pp. 801-812
    • Golnabi, H.1
  • 14
    • 4444383335 scopus 로고    scopus 로고
    • Multi-sensor system using plastic optical fibers for intrinsically safe level measurements
    • C. Vázquez, A.B. Gonzalo, S. Vargas, and J. Moltalvo Multi-sensor system using plastic optical fibers for intrinsically safe level measurements Sens. Actuators A 116 2004 22 32
    • (2004) Sens. Actuators A , vol.116 , pp. 22-32
    • Vázquez, C.1    Gonzalo, A.B.2    Vargas, S.3    Moltalvo, J.4
  • 15
    • 84861301105 scopus 로고    scopus 로고
    • Medidor de nivel de líquidos por fibra óptica con alarmas para teledetección, Patente Española, Universidad de Granada, ES2155406
    • F. Pérez-Ocón, M. Rubiño, Medidor de nivel de líquidos por fibra óptica con alarmas para teledetección, Patente Española, Universidad de Granada, ES2155406, 2001.
    • (2001)
    • Pérez-Ocón, F.1    Rubiño, M.2
  • 16
    • 0003998388 scopus 로고    scopus 로고
    • 78th ed. CRC Press Boca Raton, New York
    • Handbook of Chemistry and Physics 78th ed. 1997 CRC Press Boca Raton, New York
    • (1997) Handbook of Chemistry and Physics
  • 17
    • 0034745202 scopus 로고    scopus 로고
    • Optical measurement of cardiac rhythm using a personal computer with telediagnosis possibilities
    • F. Pérez-Ocón, A. Abarca, J. Abril, and E. Hita Optical measurement of cardiac rhythm using a personal computer with telediagnosis possibilities J. Biomed. Opt. 6 2001 90 96
    • (2001) J. Biomed. Opt. , vol.6 , pp. 90-96
    • Pérez-Ocón, F.1    Abarca, A.2    Abril, J.3    Hita, E.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.