메뉴 건너뛰기




Volumn 52, Issue 5 I, 2005, Pages 1305-1310

System performance simulations of the RatCAP awake rat brain scanner

Author keywords

SimSET; Small animal imaging

Indexed keywords

DETECTOR GEOMETRY; PARALLAX GEOMETRY; SIMSET; SMALL ANIMAL IMAGING;

EID: 29144440946     PISSN: 00189499     EISSN: None     Source Type: Journal    
DOI: 10.1109/TNS.2005.858236     Document Type: Article
Times cited : (7)

References (9)
  • 1
    • 0034961911 scopus 로고    scopus 로고
    • Cerebral perfusion during anesthesia with fentanyl, isofluorane or pentobarbital in normal rats studies with arterial spin-labeled MRI
    • K. S. Hendrich, P. M. Kochanek, J. A. Melick, J. K. Schiding, K. D. Statler, D. S. Williams, D. W. Marion, and C. Ho, "Cerebral perfusion during anesthesia with fentanyl, isofluorane or pentobarbital in normal rats studies with arterial spin-labeled MRI," Magn. Reson. Med., vol. 46, pp. 202-206, 2001.
    • (2001) Magn. Reson. Med. , vol.46 , pp. 202-206
    • Hendrich, K.S.1    Kochanek, P.M.2    Melick, J.A.3    Schiding, J.K.4    Statler, K.D.5    Williams, D.S.6    Marion, D.W.7    Ho, C.8
  • 4
    • 0031212788 scopus 로고    scopus 로고
    • Design of a high-resolution, high-sensitivity PET camera for human brains and small animals
    • August
    • W. W. Moses, P. R. G. Virador, S. E. Derenzo, R. H. Huesman, and T. F. Budinger, "Design of a high-resolution, high-sensitivity PET camera for human brains and small animals," IEEE Trans. Nucl. Sci., vol. 44. no. 4. August 1997.
    • IEEE Trans. Nucl. Sci. , vol.44 , Issue.4 , pp. 1997
    • Moses, W.W.1    Virador, P.R.G.2    Derenzo, S.E.3    Huesman, R.H.4    Budinger, T.F.5
  • 7
    • 0020194763 scopus 로고
    • Maximum likelihood reconstruction in emission tomography
    • L. A. Shepp and Y. Vardi, "Maximum likelihood reconstruction in emission tomography," IEEE Trans. Med. Imug., vol. MI-1, pp. 113-122. 1982.
    • (1982) IEEE Trans. Med. Imug. , vol.MI-1 , pp. 113-122
    • Shepp, L.A.1    Vardi, Y.2
  • 9
    • 0038382221 scopus 로고    scopus 로고
    • Effects of inter-crystal cross-talk on multi-element LSO/APD PET detectors
    • P. Vaska, S. P. Stoll, C. L. Woody, D. J. Schlyer, and S. Shokouhi, "Effects of inter-crystal cross-talk on multi-element LSO/APD PET detectors," IEEE Trans. Nucl. Sci., vol. 50. pp. 362-366, 2003.
    • (2003) IEEE Trans. Nucl. Sci. , vol.50 , pp. 362-366
    • Vaska, P.1    Stoll, S.P.2    Woody, C.L.3    Schlyer, D.J.4    Shokouhi, S.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.