메뉴 건너뛰기




Volumn 2004, Issue , 2004, Pages

Detection of coronary artery disease with MCG

Author keywords

Coronary artery disease; Magnetic field maps; Magnetocardiography; Shielding; Signal morphology; Source parameters; Time intervals

Indexed keywords

ANGIOCARDIOGRAPHY; ARTICLE; CORONARY ARTERY DISEASE; DIAGNOSTIC VALUE; ELECTROCARDIOGRAM; HEART ARRHYTHMIA; HEART INFARCTION; HEART RATE; HEART REPOLARIZATION; HEART SCINTISCANNING; HUMAN; MAGNETIC FIELD; MAGNETOCARDIOGRAPHY; NON INVASIVE MEASUREMENT; PREDICTION; PRIORITY JOURNAL; QRS COMPLEX; QT DISPERSION; QT INTERVAL; QT PROLONGATION; QUANTITATIVE ANALYSIS; SENSITIVITY AND SPECIFICITY; ST SEGMENT DEPRESSION;

EID: 29144437250     PISSN: 15268748     EISSN: 15268748     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (15)

References (27)
  • 1
    • 0020643212 scopus 로고
    • Magnetic measurement of S-T and T-Q segment shift in humans. Part II: Exercise-induced S-T segment depression
    • Cohen D, Savard P, Rifkin RD, Lepeschkin E, Strauss WE. Magnetic measurement of S-T and T-Q segment shift in humans. Part II: exercise-induced S-T segment depression. Circ Res 1983;53:274-9.
    • (1983) Circ. Res. , vol.53 , pp. 274-279
    • Cohen, D.1    Savard, P.2    Rifkin, R.D.3    Lepeschkin, E.4    Strauss, W.E.5
  • 2
    • 29144460261 scopus 로고    scopus 로고
    • Study of ventricular repolarization in patients with myocardial ischemia, using unshielded multichannel magnetocardiography
    • Nowak H, Haueisen J, Giessler F, Huonker R, editors. Berlin Offenbach: VDE Verlag
    • Fenici R, Brisinda D, Nenonen J, Makijarvi M, Fenici P. Study of ventricular repolarization in patients with myocardial ischemia, using unshielded multichannel magnetocardiography. In: Nowak H, Haueisen J, Giessler F, Huonker R, editors. Biomag 2002. Proceedings of the 13th International Conference on Biomagnetism; Berlin Offenbach: VDE Verlag; 2002. p. 520-3.
    • (2002) Biomag. 2002. Proceedings of the 13th International Conference on Biomagnetism , pp. 520-523
    • Fenici, R.1    Brisinda, D.2    Nenonen, J.3    Makijarvi, M.4    Fenici, P.5
  • 3
    • 0032814236 scopus 로고    scopus 로고
    • Spatial distribution of QT dispersion under stress in coronary artery disease
    • Hailer B, van Leeuwen P, Lange S, Wehr M. Spatial distribution of QT dispersion under stress in coronary artery disease. J Electrocardiol 1999A;32:207-16.
    • (1999) J. Electrocardiol. , vol.32 , pp. 207-216
    • Hailer, B.1    van Leeuwen, P.2    Lange, S.3    Wehr, M.4
  • 4
    • 0032824707 scopus 로고    scopus 로고
    • Coronary artery disease may alter the spatial dispersion of QT interval at rest
    • Hailer B, van Leeuwen P, Lange S, Pilath M, Wehr M. Coronary artery disease may alter the spatial dispersion of QT interval at rest. A N E 1999B;4:267-73.
    • (1999) A. N. E. , vol.4 , pp. 267-273
    • Hailer, B.1    van Leeuwen, P.2    Lange, S.3    Pilath, M.4    Wehr, M.5
  • 7
    • 29144432271 scopus 로고    scopus 로고
    • The value of magnetocardiography in patients with and without relevant stenoses of the coronary arteries using an unshielded system
    • submitted
    • Hailer B, Chaikovsky I, Auth-Eisernitz S, Schäfer H, van Leeuwen P. The value of magnetocardiography in patients with and without relevant stenoses of the coronary arteries using an unshielded system. PACE 2004, submitted.
    • (2004) PACE
    • Hailer, B.1    Chaikovsky, I.2    Auth-Eisernitz, S.3    Schäfer, H.4    van Leeuwen, P.5
  • 8
    • 0034129210 scopus 로고    scopus 로고
    • Detection of exercise-induced myocardial ischemia by multichannel magnetocardiography in single vessel coronary artery disease
    • Hänninen H, Takala P, Mäkijärvi M, Montonen J, Korhonen P, Oikarinen L, Nenonen J, et al. Detection of exercise-induced myocardial ischemia by multichannel magnetocardiography in single vessel coronary artery disease. A N E 2000;5(2):147-57.
    • (2000) A. N. E. , vol.5 , Issue.2 , pp. 147-157
    • Hänninen, H.1    Takala, P.2    Mäkijärvi, M.3    Montonen, J.4    Korhonen, P.5    Oikarinen, L.6    Nenonen, J.7
  • 9
    • 0034922389 scopus 로고    scopus 로고
    • Recording locations in multichannel magnetocardiography and body surface potential mapping sensitive for regional exercise induced myocardial ischemia
    • Hänninen H, Takala P, Mäkijärvi M, Montonen J, Korhonen P, Oikarinen L, et al. Recording locations in multichannel magnetocardiography and body surface potential mapping sensitive for regional exercise induced myocardial ischemia. Basic Res Cardiol 2001;96:405-14.
    • (2001) Basic. Res. Cardiol. , vol.96 , pp. 405-414
    • Hänninen, H.1    Takala, P.2    Mäkijärvi, M.3    Montonen, J.4    Korhonen, P.5    Oikarinen, L.6
  • 10
    • 0036263584 scopus 로고    scopus 로고
    • Features of ST segment and T-wave in exercise induced myocardial ischemia evaluated with multichannel magnetocardiography
    • Hänninen H, Takala P, Korhonen P, Oikarinen L, Mäkijärvi M, Nenonen J, et al. Features of ST segment and T-wave in exercise induced myocardial ischemia evaluated with multichannel magnetocardiography. Ann Med 2002;4:120-9.
    • (2002) Ann. Med. , vol.4 , pp. 120-129
    • Hänninen, H.1    Takala, P.2    Korhonen, P.3    Oikarinen, L.4    Mäkijärvi, M.5    Nenonen, J.6
  • 11
    • 0028874267 scopus 로고
    • QT dispersion and components of the QT interval in ischaemia and infarction
    • Higham PD, Furniss SS, Campbell RWF. QT dispersion and components of the QT interval in ischaemia and infarction. Br Heart J 1995;73:32-6.
    • (1995) Br. Heart J. , vol.73 , pp. 32-36
    • Higham, P.D.1    Furniss, S.S.2    Campbell, R.W.F.3
  • 12
    • 0035156251 scopus 로고    scopus 로고
    • A method for detecting myocardial abnormality by using a current-ratio map calculated from an exercise-induced magnetocardiogram
    • Kandori A, Kanzaki H, Miyatake K, Hashimoto S, Itoh S, Tanaka N, et al. A method for detecting myocardial abnormality by using a current-ratio map calculated from an exercise-induced magnetocardiogram. Med Biol Eng Comput 2001;39:29-34.
    • (2001) Med. Biol. Eng. Comput. , vol.39 , pp. 29-34
    • Kandori, A.1    Kanzaki, H.2    Miyatake, K.3    Hashimoto, S.4    Itoh, S.5    Tanaka, N.6
  • 13
    • 29144491539 scopus 로고    scopus 로고
    • QT interval distribution in coronary artery disease determined in a large array biomagnetometer
    • Nowak H, Haueisen J, Giessler F, Huonker R, editors. Berlin Offenbach: VDE Verlag
    • Klein A, Van Leeuwen P, Hailer B, Lange S, Lukat M, Geue D, et al. QT interval distribution in coronary artery disease determined in a large array biomagnetometer. In: Nowak H, Haueisen J, Giessler F, Huonker R, editors. Biomag 2002. Proceedings of the 13th International Conference on Biomagnetism; Berlin Offenbach: VDE Verlag; 2002. p. 557-9.
    • (2002) Biomag 2002. Proceedings of the 13th International Conference on Biomagnetism , pp. 557-559
    • Klein, A.1    Van Leeuwen, P.2    Hailer, B.3    Lange, S.4    Lukat, M.5    Geue, D.6
  • 14
    • 0025165427 scopus 로고
    • Complementary nature of electrocardiographic and magnetocardiographic data in patients with ischemic heart disease
    • Lant J, Stroink G, ten Voorde B, Horacek BM, Montague T. Complementary nature of electrocardiographic and magnetocardiographic data in patients with ischemic heart disease. J Electrocardiol 1990;23:315-22.
    • (1990) J. Electrocardiol. , vol.23 , pp. 315-322
    • Lant, J.1    Stroink, G.2    ten Voorde, B.3    Horacek, B.M.4    Montague, T.5
  • 15
    • 0032513090 scopus 로고    scopus 로고
    • Noninvasive biomagnetic imaging in coronary artery disease based on individual current density maps of the heart
    • Leder U, Pohl HP, Michaelsen S, Fritschi T, Huck M, Eichhorn J, Müller S, et al. Noninvasive biomagnetic imaging in coronary artery disease based on individual current density maps of the heart. Int J Card 1998;64:83-92.
    • (1998) Int. J. Card. , vol.64 , pp. 83-92
    • Leder, U.1    Pohl, H.P.2    Michaelsen, S.3    Fritschi, T.4    Huck, M.5    Eichhorn, J.6    Müller, S.7
  • 16
    • 85009317151 scopus 로고    scopus 로고
    • Current density estimation on the left ventricular epicardium: A potential method for ischemia localization
    • Pesola K, Hänninen H, Lauerma K, Lötjönen J, Mäkijärvi M, Nenonen J, et al. Current density estimation on the left ventricular epicardium: A potential method for ischemia localization. Biomed Tech1999;44(suppl 2):143-6.
    • (1999) Biomed. Tech , vol.44 , Issue.SUPPL. 2 , pp. 143-146
    • Pesola, K.1    Hänninen, H.2    Lauerma, K.3    Lötjönen, J.4    Mäkijärvi, M.5    Nenonen, J.6
  • 18
    • 0009065150 scopus 로고    scopus 로고
    • Detection of myocardial ischemia by magntetocardiogram using 64-channel SQUID system
    • Nenonen J, Ilmoniemi RJ, Katila T, editors. Espoo: Helsinki Univ Technology
    • Sato M, Terada Y, Mitsui T, Myashita T, Kandori A, Tsukada K. Detection of myocardial ischemia by magntetocardiogram using 64-channel SQUID system. In: Nenonen J, Ilmoniemi RJ, Katila T, editors. Biomag2000. Proc 12th Int Conf on Biomagnetism; Espoo: Helsinki Univ Technology; 2001. p. 523-6.
    • (2001) Biomag2000. Proc 12th Int Conf on Biomagnetism , pp. 523-526
    • Sato, M.1    Terada, Y.2    Mitsui, T.3    Myashita, T.4    Kandori, A.5    Tsukada, K.6
  • 19
    • 0017843995 scopus 로고
    • QT interval prolongation as a predictor of sudden death in patients with myocardial infarction
    • Schwartz PJ, Wolf S. QT interval prolongation as a predictor of sudden death in patients with myocardial infarction. Circulation 1978;57:1074-7.
    • (1978) Circulation , vol.57 , pp. 1074-1077
    • Schwartz, P.J.1    Wolf, S.2
  • 20
    • 0036150141 scopus 로고    scopus 로고
    • Heart rate adjustment of magnetic field map rotation in detection of myocardial ischemia in exercise magnetocardiography
    • Takala P, Hänninen H, Montonen J, Korhonen P, Mäkijärvi M, Nenonen J, et al. Heart rate adjustment of magnetic field map rotation in detection of myocardial ischemia in exercise magnetocardiography. Basic Res Cardiol 2002;97:88-96.
    • (2002) Basic Res. Cardiol. , vol.97 , pp. 88-96
    • Takala, P.1    Hänninen, H.2    Montonen, J.3    Korhonen, P.4    Mäkijärvi, M.5    Nenonen, J.6
  • 21
    • 0033999401 scopus 로고    scopus 로고
    • An iso-integral mapping technique using magnetocardiogram an its possible use for diagnosis of ischemic heart disease
    • Tsukada K, Miyashita T, Kandori A, Mitsui T, Terada Y, Sato M, et al. An iso-integral mapping technique using magnetocardiogram an its possible use for diagnosis of ischemic heart disease. Int J Card Imaging 2000;16:55-60.
    • (2000) Int. J. Card. Imaging , vol.16 , pp. 55-60
    • Tsukada, K.1    Miyashita, T.2    Kandori, A.3    Mitsui, T.4    Terada, Y.5    Sato, M.6
  • 22
    • 0029858863 scopus 로고    scopus 로고
    • Spatial distribution of QT intervals: An alternative approach to QT dispersion
    • Van Leeuwen P, Hailer B, Wehr M. Spatial distribution of QT intervals: an alternative approach to QT dispersion. PACE 1996;19:1894-9.
    • (1996) PACE , vol.19 , pp. 1894-1899
    • Van Leeuwen, P.1    Hailer, B.2    Wehr, M.3
  • 23
    • 0141826578 scopus 로고    scopus 로고
    • Changes in current dipole parameters in patients with coronary artery disease with and without myocardial infarction
    • Van Leeuwen P, Hailer B, Wehr M. Changes in current dipole parameters in patients with coronary artery disease with and without myocardial infarction. Biomed Tech 1997;42:132-5.
    • (1997) Biomed. Tech. , vol.42 , pp. 132-135
    • Van Leeuwen, P.1    Hailer, B.2    Wehr, M.3
  • 24
    • 0000386707 scopus 로고    scopus 로고
    • Spatial and temporal changes during the QT interval in the magnetic field of patients with coronary artery disease
    • Van Leeuwen P, Hailer B, Lange S, Donker D, Grönemeyer D. Spatial and temporal changes during the QT interval in the magnetic field of patients with coronary artery disease. Biomed Tech 1999A;44:139-42.
    • (1999) Biomed. Tech. , vol.44 , pp. 139-142
    • Van Leeuwen, P.1    Hailer, B.2    Lange, S.3    Donker, D.4    Grönemeyer, D.5
  • 26
    • 0043202570 scopus 로고    scopus 로고
    • Spatial distribution of repolarization times in patients with coronary artery disease
    • Van Leeuwen P, Hailer B, Lange S, Grönemeyer D. Spatial distribution of repolarization times in patients with coronary artery disease. PACE 2003;26:1706-14.
    • (2003) PACE , vol.26 , pp. 1706-1714
    • Van Leeuwen, P.1    Hailer, B.2    Lange, S.3    Grönemeyer, D.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.