메뉴 건너뛰기




Volumn 38, Issue 14, 2005, Pages 2449-2461

Novel sorbent extraction technique using a chelating agent impregnated porous PTFE filter tube: Preconcentration of rare earth elements (REEs) with bis(2-ethyl-hexyl)hydrogen phosphate (HDEHP) loaded porous PTFE filter tube prior to determination by ICP-MS

Author keywords

Bis(2 ethyl hexyl)hydrogen phosphate; HDEHP; ICP MS; Impregnated; Preconcentration; PTFE filter; Rare earth elements; REEs; Solid liquid extraction

Indexed keywords


EID: 28844473173     PISSN: 00032719     EISSN: 1532236X     Source Type: Journal    
DOI: 10.1080/00032710500318189     Document Type: Article
Times cited : (6)

References (16)
  • 1
    • 0030402753 scopus 로고    scopus 로고
    • Determination of the rare earth elements in aqueous samples at sub-ppt levels by inductively coupled plasma mass spectrometry and flow injection ICPMS
    • Aggarwal, J.K., Shabani, M.B., Palmer, M.R., and Rangnarsdottir, K.V. 1996. Determination of the rare earth elements in aqueous samples at sub-ppt levels by inductively coupled plasma mass spectrometry and flow injection ICPMS. Anal. Chem, 68: 4418-4423.
    • (1996) Anal. Chem. , vol.68 , pp. 4418-4423
    • Aggarwal, J.K.1    Shabani, M.B.2    Palmer, M.R.3    Rangnarsdottir, K.V.4
  • 2
    • 0035445481 scopus 로고    scopus 로고
    • Determination of sub-parts-per-trillion levels of rare earth elements in natural waters by inductively coupled plasma time-of-flight mass spectrometry after flow injection on-line sorption preconcentration in a knotted reactor
    • Benkhedda, K.H., Infante, G., Ivanova, E., and Adams, F.C. 2001. Determination of sub-parts-per-trillion levels of rare earth elements in natural waters by inductively coupled plasma time-of-flight mass spectrometry after flow injection on-line sorption preconcentration in a knotted reactor. J. Anal. At. Spectrom, 16: 995-1001.
    • (2001) J. Anal. At. Spectrom. , vol.16 , pp. 995-1001
    • Benkhedda, K.H.1    Infante, G.2    Ivanova, E.3    Adams, F.C.4
  • 3
    • 0002089641 scopus 로고    scopus 로고
    • A simple co-precipitation inductively coupled plasma mass spectrometric method for the determination of uranium in seawater
    • Chou, C.L. and Moffatt, J.D. 2000. A simple co-precipitation inductively coupled plasma mass spectrometric method for the determination of uranium in seawater. Fresenius' J. Anal. Chem., 368: 59-61.
    • (2000) Fresenius' J. Anal. Chem. , vol.368 , pp. 59-61
    • Chou, C.L.1    Moffatt, J.D.2
  • 4
    • 0030246069 scopus 로고    scopus 로고
    • On-line method for inductively coupled plasma mass spectrometric determination of rareearth elements in highly saline brines
    • Halicz, L., Gavrieli, I., and Dorfman, E.J. 1996. On-line method for inductively coupled plasma mass spectrometric determination of rareearth elements in highly saline brines. Anal. At. Spectrom., 11: 811-814.
    • (1996) Anal. At. Spectrom. , vol.11 , pp. 811-814
    • Halicz, L.1    Gavrieli, I.2    Dorfman, E.J.3
  • 5
    • 0001742005 scopus 로고    scopus 로고
    • Micro-column separation/preconcentration combined with fluorinating electrothermal vaporization-inductively coupled plasma-atomic emission spectrometry for determination of ultratrace rare earth elements
    • Hongchun, X., Bin, H., and Zucheng, J. 2000. Micro-column separation/preconcentration combined with fluorinating electrothermal vaporization-inductively coupled plasma-atomic emission spectrometry for determination of ultratrace rare earth elements. J. Anal. At. Spectrom., 15: 759-762.
    • (2000) J. Anal. At. Spectrom. , vol.15 , pp. 759-762
    • Hongchun, X.1    Bin, H.2    Zucheng, J.3
  • 6
    • 0026942990 scopus 로고
    • Determination of rare earth elements in seawater by inductively coupled plasma-mass spectrometry
    • Moller, P., Dulski, P., and Luck, J. 1992. Determination of rare earth elements in seawater by inductively coupled plasma-mass spectrometry. Spectrochim. Acta Part B, 47: 1379-1387.
    • (1992) Spectrochim. Acta Part B , vol.47 , pp. 1379-1387
    • Moller, P.1    Dulski, P.2    Luck, J.3
  • 7
    • 0040882961 scopus 로고    scopus 로고
    • Novel sorbent extraction technique using a chelating agent impregnated porous PTFE filter tube: Preconcentration of In(III) with a bis(2-ethylhexyl) hydrogen phosphate (HDEHP) loaded porous PTFE filter tube
    • Murakami, M. and Takada, T. 1999. Novel sorbent extraction technique using a chelating agent impregnated porous PTFE filter tube: preconcentration of In(III) with a bis(2-ethylhexyl) hydrogen phosphate (HDEHP) loaded porous PTFE filter tube. Anal. Commun., 36: 185-188.
    • (1999) Anal. Commun. , vol.36 , pp. 185-188
    • Murakami, M.1    Takada, T.2
  • 8
    • 0000092354 scopus 로고
    • Analytical perspective. Solid phase techniques for the preconcentration of trace metals from natural waters
    • Nickson, R.A., Hill, S.J., and Worsfold, P.J. 1995. Analytical perspective. Solid phase techniques for the preconcentration of trace metals from natural waters. Anal. Proc., 32: 387-396.
    • (1995) Anal. Proc. , vol.32 , pp. 387-396
    • Nickson, R.A.1    Hill, S.J.2    Worsfold, P.J.3
  • 10
    • 84996036495 scopus 로고
    • Multi-element determination of trace elements in seawater by gallium coprecipitation and inductively coupled plasma mass spectrometry
    • Sawatari, H., Fujimori, E., and Haraguchi, H. 1995. Multi-element determination of trace elements in seawater by gallium coprecipitation and inductively coupled plasma mass spectrometry. Anal. Sci., 11: 369-374.
    • (1995) Anal. Sci. , vol.11 , pp. 369-374
    • Sawatari, H.1    Fujimori, E.2    Haraguchi, H.3
  • 11
    • 0000727222 scopus 로고
    • Preconcentration of trace rare-earth elements in seawater by complexation with bis(2-ethylhexyl) hydrogen phosphate and 2-ethylhexyl dihydrogen phosphate adsorbed on a C18 cartridge and determination by inductively coupled plasma mass spectrometry
    • Shabani, M.B., Akagi, T., and Masuda, A. 1992. Preconcentration of trace rare-earth elements in seawater by complexation with bis(2-ethylhexyl) hydrogen phosphate and 2-ethylhexyl dihydrogen phosphate adsorbed on a C18 cartridge and determination by inductively coupled plasma mass spectrometry. Anal. Chem., 64: 737-743.
    • (1992) Anal. Chem. , vol.64 , pp. 737-743
    • Shabani, M.B.1    Akagi, T.2    Masuda, A.3
  • 12
    • 11944268054 scopus 로고
    • Determination of trace lanthanides and yttrium in seawater by inductively coupled plasma mass spectrometry after preconcentration with solvent extraction and back-extraction
    • Shabani, M.B., Akagi, T., Shimizu, H., and Masuda, A. 1990. Determination of trace lanthanides and yttrium in seawater by inductively coupled plasma mass spectrometry after preconcentration with solvent extraction and back-extraction. Anal. Chem., 62: 2709-2714.
    • (1990) Anal. Chem. , vol.62 , pp. 2709-2714
    • Shabani, M.B.1    Akagi, T.2    Shimizu, H.3    Masuda, A.4
  • 13
    • 0032507792 scopus 로고    scopus 로고
    • Determination of trace elements in seawater by fluorinated metal alkoxide glass-immobilized 8-hydroxyquinoline concentration and high-resolution inductively coupled plasma mass spectrometry detection
    • Sohrin, Y., Iwamoto, S., Akiyama, S., Fujita, T., Kugii, T., Obata, H., Nakayama, E., Fujishima, Y., Hagiwara, H., Ueda, K., and Matsui, M. 1998. Determination of trace elements in seawater by fluorinated metal alkoxide glass-immobilized 8-hydroxyquinoline concentration and high-resolution inductively coupled plasma mass spectrometry detection. Anal. Chim. Acta, 363: 11-19.
    • (1998) Anal. Chim. Acta , vol.363 , pp. 11-19
    • Sohrin, Y.1    Iwamoto, S.2    Akiyama, S.3    Fujita, T.4    Kugii, T.5    Obata, H.6    Nakayama, E.7    Fujishima, Y.8    Hagiwara, H.9    Ueda, K.10    Matsui, M.11
  • 14
    • 0035975502 scopus 로고    scopus 로고
    • Determination of transition and rare earth elements in seawater by flow injection inductively coupled plasma time-of-flight mass spectrometry
    • Wille, S.N. and Sturgeon, R.E. 2001. Determination of transition and rare earth elements in seawater by flow injection inductively coupled plasma time-of-flight mass spectrometry. Spectrochim. Acta Part B, 56: 1707-1716.
    • (2001) Spectrochim. Acta Part B , vol.56 , pp. 1707-1716
    • Wille, S.N.1    Sturgeon, R.E.2
  • 15
    • 0042583718 scopus 로고    scopus 로고
    • Low blank preconcentration technique for the determination of lead, copper, and cadmium in small-volume seawater samples by isotope dilution ICPMS
    • Wu, J. and Boyle, E.A. 1997. Low blank preconcentration technique for the determination of lead, copper, and cadmium in small-volume seawater samples by isotope dilution ICPMS. Anal. Chem., 69: 2464-2470.
    • (1997) Anal. Chem. , vol.69 , pp. 2464-2470
    • Wu, J.1    Boyle, E.A.2
  • 16
    • 13444291920 scopus 로고    scopus 로고
    • Multielement determination of trace metals in seawater by ICP-MS using a chelating resin-packed minicolumn for preconcentration
    • Zhu, Y., Itoh, A., and Haraguchi, H. 2005. Multielement determination of trace metals in seawater by ICP-MS using a chelating resin-packed minicolumn for preconcentration. Bull. Chem. Soc. Jpn., 78: 107-115.
    • (2005) Bull. Chem. Soc. Jpn. , vol.78 , pp. 107-115
    • Zhu, Y.1    Itoh, A.2    Haraguchi, H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.