메뉴 건너뛰기




Volumn 4, Issue , 2005, Pages

Suppression of AC railway power-line interference in ECG signals recorded by public access defibrillators

Author keywords

[No Author keywords available]

Indexed keywords

ELECTRIC POWER LINE FREQUENCY INTERFERENCE; PUBLIC ACCESS DEFIBRILLATORS; RAILWAY INTERFERENCE SUPPRESSION;

EID: 28844471925     PISSN: 1475925X     EISSN: 1475925X     Source Type: Journal    
DOI: 10.1186/1475-925X-4-65     Document Type: Article
Times cited : (3)

References (17)
  • 1
    • 0025805613 scopus 로고
    • Improving survival from sudden cardiac arrest: The 'chain of survival' concept: A statement for health professionals from the Advanced Cardiac Live Support Subcommittee and the Emergency Cardiac Care Committee
    • American Heart Association
    • Cummins RO, Ornato JP, Thies WH, Pepe PE: Improving survival from sudden cardiac arrest: the 'chain of survival' concept: a statement for health professionals from the Advanced Cardiac Live Support Subcommittee and the Emergency Cardiac Care Committee. American Heart Association. Circulation, 1991, 83:1832-1847.
    • (1991) Circulation , vol.83 , pp. 1832-1847
    • Cummins, R.O.1    Ornato, J.P.2    Thies, W.H.3    Pepe, P.E.4
  • 3
    • 0003175127 scopus 로고    scopus 로고
    • Guidelines 2000 for cardiopulmonary resuscitation and emergency cardiac care - An international consensus on science. Part 4: Automated external deribrillator
    • The American Heart Association in collaboration with the International Liaison Committee on Resuscitation (ILCOR)
    • The American Heart Association in collaboration with the International Liaison Committee on Resuscitation (ILCOR): Guidelines 2000 for cardiopulmonary resuscitation and emergency cardiac care - an international consensus on science. Part 4: automated external deribrillator. Resuscitation, 2000, 462:73-91.
    • (2000) Resuscitation , vol.462 , pp. 73-91
  • 4
    • 2442718992 scopus 로고    scopus 로고
    • Safety aspects for public access defibrillation using automated external defibrillators near high-voltage power lines
    • Schlimp CJ, Breiteneder M, Lederer W, Safety aspects for public access defibrillation using automated external defibrillators near high-voltage power lines Acta Anaesthesiol Scand, 2004, 48:595-600.
    • (2004) Acta Anaesthesiol. Scand. , vol.48 , pp. 595-600
    • Schlimp, C.J.1    Breiteneder, M.2    Lederer, W.3
  • 6
    • 25444471306 scopus 로고    scopus 로고
    • Suppression of 16.7 Hz interference generated by the power supply of the railway systems
    • Christov II, Iliev GL: Suppression of 16.7 Hz interference generated by the power supply of the railway systems. Biomed Eng OnLine, 2005, 4:16.
    • (2005) Biomed. Eng. OnLine , vol.4 , pp. 16
    • Christov, I.I.1    Iliev, G.L.2
  • 9
    • 21544457222 scopus 로고    scopus 로고
    • Influence of electromagnetic interference on the human electrocardiogram in automated external defibrillators
    • Schlimp CJ, Breiteneder M, Lederer W: Influence of electromagnetic interference on the human electrocardiogram in automated external defibrillators. Resuscitation, 2005, 66:105-106.
    • (2005) Resuscitation , vol.66 , pp. 105-106
    • Schlimp, C.J.1    Breiteneder, M.2    Lederer, W.3
  • 10
    • 26944485759 scopus 로고    scopus 로고
    • Commission decision concerning the technical specification for interoperability relating to the energy subsystem of the trans-European high-speed rail system
    • Commission decision concerning the technical specification for interoperability relating to the energy subsystem of the trans-European high-speed rail system. Official journal of the European communities, 2002, 45:280-369.
    • (2002) Official Journal of the European Communities , vol.45 , pp. 280-369
  • 11
    • 28544442841 scopus 로고    scopus 로고
    • Subtraction of 16.67 Hz railroad net interference from the electrocardiogram: Application for automatic external defibrillators
    • Jekova I, Krasteva V: Subtraction of 16.67 Hz railroad net interference from the electrocardiogram: application for automatic external defibrillators. Physiol. Meas., 2005, 26:987-1003
    • (2005) Physiol. Meas. , vol.26 , pp. 987-1003
    • Jekova, I.1    Krasteva, V.2
  • 14
    • 0026203883 scopus 로고
    • Applications of adaptive filtering to ECG analysis: Noise cancellation and arrhythmia detection
    • Thakor NV, Zhu YS: Applications of adaptive filtering to ECG analysis: noise cancellation and arrhythmia detection. IEEE Trans Biomed Eng, 1991, 38:785-793.
    • (1991) IEEE Trans. Biomed. Eng. , vol.38 , pp. 785-793
    • Thakor, N.V.1    Zhu, Y.S.2
  • 15
    • 0030032972 scopus 로고    scopus 로고
    • A comparison of Adaptive and Nonadaptive Filters for Reduction of Power Line Interference in the ECG
    • Hamilton PS: A comparison of Adaptive and Nonadaptive Filters for Reduction of Power Line Interference in the ECG. IEEE Trans Biomed Eng, 1996, 43:105-109.
    • (1996) IEEE Trans. Biomed. Eng. , vol.43 , pp. 105-109
    • Hamilton, P.S.1
  • 16
    • 20544460698 scopus 로고    scopus 로고
    • Power-line interference cancellation in ECG signals
    • Dotsinsky I, Stoyanov T: Power-line interference cancellation in ECG signals. Biomed Instr Techn, 2005, 39:155-162.
    • (2005) Biomed. Instr. Techn. , vol.39 , pp. 155-162
    • Dotsinsky, I.1    Stoyanov, T.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.