메뉴 건너뛰기




Volumn 555, Issue 1, 2006, Pages 75-83

On-line monitoring of trihalomethane concentrations in drinking water distribution systems using capillary membrane sampling-gas chromatography

Author keywords

Disinfection by products; Drinking water; Gas chromatography; On line monitoring; Trihalomethanes (THM4); Water analysis

Indexed keywords

CELL MEMBRANES; CONCENTRATION (PROCESS); DECISION MAKING; GAS CHROMATOGRAPHY; MONITORING; OPTIMIZATION; WATER ANALYSIS; WATER DISTRIBUTION SYSTEMS; WATER QUALITY;

EID: 28844460494     PISSN: 00032670     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.aca.2005.08.066     Document Type: Article
Times cited : (33)

References (30)
  • 2
    • 0000931409 scopus 로고    scopus 로고
    • National Primary Drinking Water Regulations: Disinfectants and Disinfection By-products Rule: Final Rule
    • December 16
    • USEPA, National Primary Drinking Water Regulations: Disinfectants and Disinfection By-products Rule: Final Rule, Fed. Reg. 63,241, 68390, December 16, 1998.
    • (1998) Fed. Reg. , vol.63 , Issue.241 , pp. 68390
  • 14
    • 24944452248 scopus 로고    scopus 로고
    • Measuring the concentrations of drinking water disinfection by-products using capillary membrane sampling-flow injection analysis
    • in press.
    • G. Geme, M.A. Brown, P.S. Simone, G.L. Emmert, Measuring the concentrations of drinking water disinfection by-products using capillary membrane sampling-flow injection analysis, Water Res., 2005, in press.
    • (2005) Water Res.
    • Geme, G.1    Brown, M.A.2    Simone, P.S.3    Emmert, G.L.4
  • 18
    • 33344478037 scopus 로고    scopus 로고
    • Supported capillary membrane sampling-gas chromatography on a valve with a pulsed discharge photoionization detector
    • in press.
    • G.L. Emmert, M.A. Brown, Z. Liao, G. Cao, C.N. Duty, Supported capillary membrane sampling-gas chromatography on a valve with a pulsed discharge photoionization detector, Anal. Chim. Acta, in press.
    • Anal. Chim. Acta
    • Emmert, G.L.1    Brown, M.A.2    Liao, Z.3    Cao, G.4    Duty, C.N.5
  • 23
    • 0034257834 scopus 로고    scopus 로고
    • A.A. Sysoev Anal. Chem. 72 17 2000 4221 4229
    • (2000) Anal. Chem. , vol.72 , Issue.17 , pp. 4221-4229
    • Sysoev, A.A.1
  • 27
    • 28844465094 scopus 로고    scopus 로고
    • Appendix B, Part 136 - Definition and Procedure for the Determination of the Method Detection Limit, Revision 1.11
    • Federal Register, Appendix B, Part 136 - Definition and Procedure for the Determination of the Method Detection Limit, Revision 1.11.
    • Federal Register
  • 28
    • 0003394316 scopus 로고    scopus 로고
    • United States Environmental Protection Agency, Office of Water, EPA 814-B-96-002
    • DBP/ICR Analytical Methods Manual, United States Environmental Protection Agency, Office of Water, EPA 814-B-96-002, 1996.
    • (1996) DBP/ICR Analytical Methods Manual


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.