메뉴 건너뛰기




Volumn 108, Issue 11, 2005, Pages 954-960

Fluoroscopic guidance of percutaneous iliosacral screw insertion: Landmarks for safe positioning;Technik der perkutanen SI-verschraubung mit unterstützung durch konventionellen C-bogen

Author keywords

Fluoroscopy; Iliosacral screw; Malpositioning; Sacroiliac screw; X ray

Indexed keywords

ARTICLE; BONE SCREW; COMPUTER ASSISTED TOMOGRAPHY; FLUOROSCOPY; FRACTURE FIXATION; RISK ASSESSMENT; THREE DIMENSIONAL IMAGING; X RAY ANALYSIS;

EID: 28744432083     PISSN: 01775537     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00113-005-0967-3     Document Type: Article
Times cited : (18)

References (22)
  • 1
    • 2542497793 scopus 로고    scopus 로고
    • Computer-guidance in percutaneous screw stabilization of the iliosacral joint
    • Arand M, Kinzl L, Gebhard F (2004) Computer-guidance in percutaneous screw stabilization of the iliosacral joint. Clin Orthop 422: 201-207
    • (2004) Clin Orthop , vol.422 , pp. 201-207
    • Arand, M.1    Kinzl, L.2    Gebhard, F.3
  • 2
    • 0032455890 scopus 로고    scopus 로고
    • Iliosacral screw insertion using computer-assisted CT image guidance: A laboratory study
    • Barrick EF, O'Mara JW, Lane HE III (1998) Iliosacral screw insertion using computer-assisted CT image guidance: a laboratory study. Comput Aided Surg 3: 289-296
    • (1998) Comput Aided Surg , vol.3 , pp. 289-296
    • Barrick, E.F.1    O'Mara, J.W.2    Lane III, H.E.3
  • 3
    • 4544318385 scopus 로고    scopus 로고
    • Wirtschaftlichkeit der intraoperativen 3D-Bildgebung mit einem mobilen chirurgischen C-Bogen
    • Bischoff M, Hebecker A, Hartwig E, Gebhard F (2004) Wirtschaftlichkeit der intraoperativen 3D-Bildgebung mit einem mobilen chirurgischen C-Bogen. Unfallchirurg 107: 712-715
    • (2004) Unfallchirurg , vol.107 , pp. 712-715
    • Bischoff, M.1    Hebecker, A.2    Hartwig, E.3    Gebhard, F.4
  • 5
    • 0034277699 scopus 로고    scopus 로고
    • Transsacral versus modified pelvic landmarks for percutaneous iliosacral screw placement - A computed tomographic analysis and cadaveric study
    • Day CS, Prayson MJ, Shuler TE, Towers J, Gruen GS (2000) Transsacral versus modified pelvic landmarks for percutaneous iliosacral screw placement - a computed tomographic analysis and cadaveric study. Am J Orthop 29: 16-21
    • (2000) Am J Orthop , vol.29 , pp. 16-21
    • Day, C.S.1    Prayson, M.J.2    Shuler, T.E.3    Towers, J.4    Gruen, G.S.5
  • 6
    • 0028092022 scopus 로고
    • Percutaneous computed tomography-guided stabilization of posterior pelvic fractures
    • Ebraheim NA, Coombs R, Jackson WT, Rusin JJ (1994) Percutaneous computed tomography-guided stabilization of posterior pelvic fractures. Clin Orthop 307:222-228
    • (1994) Clin Orthop , vol.307 , pp. 222-228
    • Ebraheim, N.A.1    Coombs, R.2    Jackson, W.T.3    Rusin, J.J.4
  • 7
    • 0030965034 scopus 로고    scopus 로고
    • Morphologic considerations of the first sacral pedicle for iliosacral screw placement
    • Ebraheim NA, Xu R, Biyani A, Nadaud MC (1997) Morphologic considerations of the first sacral pedicle for iliosacral screw placement. Spine 22: 841-846
    • (1997) Spine , vol.22 , pp. 841-846
    • Ebraheim, N.A.1    Xu, R.2    Biyani, A.3    Nadaud, M.C.4
  • 8
    • 0035191045 scopus 로고    scopus 로고
    • Accuracy of computer-guided screw fixation of the sacroiliac joint
    • Gautier E, Bachler R, Heini PF, Nolte LP (2001) Accuracy of computer-guided screw fixation of the sacroiliac joint. Clin Orthop 393: 310-317
    • (2001) Clin Orthop , vol.393 , pp. 310-317
    • Gautier, E.1    Bachler, R.2    Heini, P.F.3    Nolte, L.P.4
  • 9
    • 0028089180 scopus 로고
    • The effect of thread length and location on extraction strengths of iliosacral lag screws
    • Kraemer W, Hearn T, Tile M, Powell J (1994) The effect of thread length and location on extraction strengths of iliosacral lag screws. Injury 25: 5-9
    • (1994) Injury , vol.25 , pp. 5-9
    • Kraemer, W.1    Hearn, T.2    Tile, M.3    Powell, J.4
  • 10
    • 0029830727 scopus 로고    scopus 로고
    • Internal fixation of unstable pelvic ring injuries
    • Matta JM, Tornetla P III (1996) Internal fixation of unstable pelvic ring injuries. Clin Orthop 329: 129-140
    • (1996) Clin Orthop , vol.329 , pp. 129-140
    • Matta, J.M.1    Tornetla III, P.2
  • 11
    • 0033632010 scopus 로고    scopus 로고
    • Cross-sectional geometry of the sacral ala for safe insertion of iliosacral lag screws: A computed tomography model
    • Noojin FK, Malkani AL, Haikal L, Lundquist C, Voor MJ (2000) Cross-sectional geometry of the sacral ala for safe insertion of iliosacral lag screws: a computed tomography model. J Orthop Trauma 14: 31-35
    • (2000) J Orthop Trauma , vol.14 , pp. 31-35
    • Noojin, F.K.1    Malkani, A.L.2    Haikal, L.3    Lundquist, C.4    Voor, M.J.5
  • 12
    • 28744454002 scopus 로고    scopus 로고
    • Stabilisierung des hinteren Beckenringes in Bauchlage
    • Tscherne H, Pohlemann T (Hrsg) Springer, Berlin Heidelberg New York Tokio
    • Pohlemann T, Lobenhoffer P, Tscherne H (1998) Stabilisierung des hinteren Beckenringes in Bauchlage. In: Tscherne H, Pohlemann T (Hrsg) Unfallchirurgie, Becken und Acetabulum. Springer, Berlin Heidelberg New York Tokio, S 163-179
    • (1998) Unfallchirurgie, Becken und Acetabulum , pp. 163-179
    • Pohlemann, T.1    Lobenhoffer, P.2    Tscherne, H.3
  • 13
    • 0029314802 scopus 로고
    • Early results of percutaneous iliosacral screws placed with the patient in the supine position
    • Routt ML Jr, Kregor PJ, Simonian PT, Mayo KA (1995) Early results of percutaneous iliosacral screws placed with the patient in the supine position. J Orthop Trauma 9: 207-214
    • (1995) J Orthop Trauma , vol.9 , pp. 207-214
    • Routt Jr., M.L.1    Kregor, P.J.2    Simonian, P.T.3    Mayo, K.A.4
  • 14
    • 0029689344 scopus 로고    scopus 로고
    • Radiographic recognition of lhe sacral alar slope for optimal placement of iliosacral screws: A cadaveric and clinical study
    • Routt ML Jr, Simonian PT, Agnew SG, Mann FA (1996) Radiographic recognition of lhe sacral alar slope for optimal placement of iliosacral screws: a cadaveric and clinical study. J Orthop Trauma 10: 171-177
    • (1996) J Orthop Trauma , vol.10 , pp. 171-177
    • Routt Jr., M.L.1    Simonian, P.T.2    Agnew, S.G.3    Mann, F.A.4
  • 15
    • 0031266643 scopus 로고    scopus 로고
    • Iliosacral screw fixation: Early complications of the percutaneous technique
    • Routt ML Jr, Simonian PT, Mills WJ (1997) Iliosacral screw fixation: early complications of the percutaneous technique. J Orthop Trauma 11: 584-589
    • (1997) J Orthop Trauma , vol.11 , pp. 584-589
    • Routt Jr., M.L.1    Simonian, P.T.2    Mills, W.J.3
  • 17
    • 0031466710 scopus 로고    scopus 로고
    • The unstable iliac fracture: A biomechanical evaluation of internal fixation
    • Simonian PT, Routt ML Jr, Harrington RM, Tencer AF (1997)The unstable iliac fracture: a biomechanical evaluation of internal fixation. Injury 28: 469-475
    • (1997) Injury , vol.28 , pp. 469-475
    • Simonian, P.T.1    Routt Jr., M.L.2    Harrington, R.M.3    Tencer, A.F.4
  • 19
    • 0029789346 scopus 로고    scopus 로고
    • Proximity of iliosacral screws to neurovascular structures after internal fixation
    • Templeman D, Schmidt A, Freese J, Weisman I (1996) Proximity of iliosacral screws to neurovascular structures after internal fixation. Clin Orthop 329: 194-198
    • (1996) Clin Orthop , vol.329 , pp. 194-198
    • Templeman, D.1    Schmidt, A.2    Freese, J.3    Weisman, I.4
  • 20
    • 1842450797 scopus 로고    scopus 로고
    • Neurological damage in pelvic injuries: A continuous prospective series of 50 pelvic injuries treated with an iliosacral lag screw
    • Tonelli J, Cazal C, Eid A, Badulescu A, Martinez T, Vouaillat H, Merloz P (2004) Neurological damage in pelvic injuries: a continuous prospective series of 50 pelvic injuries treated with an iliosacral lag screw. Rev Chir Orthop Reparat Appar Mot 90: 122-131
    • (2004) Rev Chir Orthop Reparat Appar Mot , vol.90 , pp. 122-131
    • Tonelli, J.1    Cazal, C.2    Eid, A.3    Badulescu, A.4    Martinez, T.5    Vouaillat, H.6    Merloz, P.7
  • 22
    • 0037397651 scopus 로고    scopus 로고
    • Iliosacral screw fixation of the posterior pelvic ring using local anaesthesia and computerised tomography
    • Ziran BH, Smith WR, Towers J, Morgan SJ (2003) Iliosacral screw fixation of the posterior pelvic ring using local anaesthesia and computerised tomography. J Bone Joint Surg Br 85: 411-418
    • (2003) J Bone Joint Surg Br , vol.85 , pp. 411-418
    • Ziran, B.H.1    Smith, W.R.2    Towers, J.3    Morgan, S.J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.