-
1
-
-
0020584956
-
Biopsy of focal hepatic lesions - Comparison of 18 and 22 gauge needles
-
J.J. Pagani Biopsy of focal hepatic lesions - comparison of 18 and 22 gauge needles Radiology 147 1983 673 675
-
(1983)
Radiology
, vol.147
, pp. 673-675
-
-
Pagani, J.J.1
-
2
-
-
0022647490
-
Complications following percutaneous liver biopsy. a multicentre retrospective study on 68,276 biopsies
-
F. Piccinino, E. Sagnelli, G. Pasquale, and G. Giusti Complications following percutaneous liver biopsy. A multicentre retrospective study on 68,276 biopsies J Hepatol 2 1986 165 173
-
(1986)
J Hepatol
, vol.2
, pp. 165-173
-
-
Piccinino, F.1
Sagnelli, E.2
Pasquale, G.3
Giusti, G.4
-
3
-
-
0024580880
-
CT-guided biopsy: Prospective analysis of 1000 procedures
-
T.J. Welch, P.F. Sheedy, C.D. Johnson, J.M. Johnson, and D.H. Stephens CT-guided biopsy: prospective analysis of 1000 procedures Radiology 171 1989 493 496
-
(1989)
Radiology
, vol.171
, pp. 493-496
-
-
Welch, T.J.1
Sheedy, P.F.2
Johnson, C.D.3
Johnson, J.M.4
Stephens, D.H.5
-
4
-
-
1642613799
-
Safety of percutaneous biopsy of hepatocellular carcinoma with an 18 gauge automated needle
-
S. Ch Yu, C. Metreweli, W.Y. Lau, W.T. Leung, C.T. Liew, and N.W.Y. Leung Safety of percutaneous biopsy of hepatocellular carcinoma with an 18 gauge automated needle Clin Radiol 52 1997 907 911
-
(1997)
Clin Radiol
, vol.52
, pp. 907-911
-
-
Ch Yu, S.1
Metreweli, C.2
Lau, W.Y.3
Leung, W.T.4
Liew, C.T.5
Leung, N.W.Y.6
-
5
-
-
0028913123
-
Indications, methods, and outcomes of percutaneous liver biopsy in England and Wales: An audit by the British Society of Gastroenterology and the Royal College of Physicians of London
-
I.T. Gilmore, A. Burroughs, I.M. Murray-Lyon, R. Williams, D. Jenkins, and A. Hopkins Indications, methods, and outcomes of percutaneous liver biopsy in England and Wales: an audit by the British Society of Gastroenterology and the Royal College of Physicians of London Gut 36 1995 437 441
-
(1995)
Gut
, vol.36
, pp. 437-441
-
-
Gilmore, I.T.1
Burroughs, A.2
Murray-Lyon, I.M.3
Williams, R.4
Jenkins, D.5
Hopkins, A.6
-
6
-
-
0025119535
-
A 21-year experience with major haemorrhage after percutaneous liver biopsy
-
D.B. McGill, J. Rakela, A.R. Zinsmeister, and B.J. Ott A 21-year experience with major haemorrhage after percutaneous liver biopsy Gastroenterology 99 1990 1396 1400
-
(1990)
Gastroenterology
, vol.99
, pp. 1396-1400
-
-
McGill, D.B.1
Rakela, J.2
Zinsmeister, A.R.3
Ott, B.J.4
-
8
-
-
0017920413
-
Percutaneous biopsy of the liver as a procedure for outpatients
-
M.C. Knauer Percutaneous biopsy of the liver as a procedure for outpatients Gastroenterology 74 1978 101 102
-
(1978)
Gastroenterology
, vol.74
, pp. 101-102
-
-
Knauer, M.C.1
-
9
-
-
0023067189
-
Prospective study of the incidence of ultrasound-detected intrahepatic and subcapsular haematomas in patients randomized to 6 or 24 hours of bed rest after percutaneous liver biopsy
-
G.Y. Minuk, L.R. Sutherland, D.A. Wiseman, F.R. MacDonald, and D.L. Ding Prospective study of the incidence of ultrasound-detected intrahepatic and subcapsular haematomas in patients randomized to 6 or 24 hours of bed rest after percutaneous liver biopsy Gastroenterology 92 1987 290 293
-
(1987)
Gastroenterology
, vol.92
, pp. 290-293
-
-
Minuk, G.Y.1
Sutherland, L.R.2
Wiseman, D.A.3
MacDonald, F.R.4
Ding, D.L.5
-
10
-
-
0018138297
-
Frequency of intrahepatic arteriovenous fistula as a sequelae to percutaneous needle puncture of the liver
-
K. Okuda, H. Musha, Y. Nakajima, K. Takayasu, Y. Suzuki, and M. Morita Frequency of intrahepatic arteriovenous fistula as a sequelae to percutaneous needle puncture of the liver Gastroenterology 74 1978 1204 1207
-
(1978)
Gastroenterology
, vol.74
, pp. 1204-1207
-
-
Okuda, K.1
Musha, H.2
Nakajima, Y.3
Takayasu, K.4
Suzuki, Y.5
Morita, M.6
-
11
-
-
0019515736
-
Intrahepatic haematoma after aspiration liver biopsy: A prospective randomised controlled trial using two different needles
-
P.L. Forssell, H.L. Bronkowsky, P.B. Anderson, and D.A. Howell Intrahepatic haematoma after aspiration liver biopsy: a prospective randomised controlled trial using two different needles Dig Dis Sci 26 1981 631 635
-
(1981)
Dig Dis Sci
, vol.26
, pp. 631-635
-
-
Forssell, P.L.1
Bronkowsky, H.L.2
Anderson, P.B.3
Howell, D.A.4
-
12
-
-
0021141221
-
CT guided liver biopsies: Eight years' experience
-
C.R. Martino, J.R. Haaga, P.J. Bryan, J.P. Li Puma, S.J. Yousef, and R.J. Alfidi CT guided liver biopsies: eight years' experience Radiology 152 1984 755 757
-
(1984)
Radiology
, vol.152
, pp. 755-757
-
-
Martino, C.R.1
Haaga, J.R.2
Bryan, P.J.3
Li Puma, J.P.4
Yousef, S.J.5
Alfidi, R.J.6
-
13
-
-
0031844703
-
Percutaneous biopsy of small hepatic lesions using an 18 gauge automated needle
-
S. Ch Yu, W.Y. Lau, W.T. Leung, C.T. Liew, N.W.Y. Leung, and C. Metreweli Percutaneous biopsy of small hepatic lesions using an 18 gauge automated needle Br J Radiol 71 1998 621 624
-
(1998)
Br J Radiol
, vol.71
, pp. 621-624
-
-
Ch Yu, S.1
Lau, W.Y.2
Leung, W.T.3
Liew, C.T.4
Leung, N.W.Y.5
Metreweli, C.6
-
14
-
-
0029965499
-
Image-guided percutaneous hepatic biopsy: Effect of ascites on the complication rate
-
A.F. Little, J.V. Ferris, G.D. Dodd III, and R.L. Baron Image-guided percutaneous hepatic biopsy: effect of ascites on the complication rate Radiology 199 1996 79 83
-
(1996)
Radiology
, vol.199
, pp. 79-83
-
-
Little, A.F.1
Ferris, J.V.2
Dodd III, G.D.3
Baron, R.L.4
|