메뉴 건너뛰기




Volumn 87, Issue 11, 2005, Pages 1575-1580

Tissue restoration after resorption of polyglycolide and poly-laevo-lactic acid screws

Author keywords

[No Author keywords available]

Indexed keywords

BIOMATERIAL; POLYGLYCOLIDE; POLYLACTIC ACID; POLYMER;

EID: 28444439511     PISSN: 0301620X     EISSN: None     Source Type: Journal    
DOI: 10.1302/0301-620X.87B11.16520     Document Type: Article
Times cited : (40)

References (51)
  • 1
    • 0021842535 scopus 로고
    • Biodegradable implants in fracture fixation: Early results of treatment of fractures of the ankle
    • Rokkanen P, Böstman O, Vainionpää S, et al. Biodegradable implants in fracture fixation: early results of treatment of fractures of the ankle. Lancet 1985;1:1422-4.
    • (1985) Lancet , vol.1 , pp. 1422-1424
    • Rokkanen, P.1    Böstman, O.2    Vainionpää, S.3
  • 2
    • 0022450162 scopus 로고
    • FOS splint in the treatment of fractures
    • (in German)
    • Haas HG. FOS splint in the treatment of fractures. Handchir Mikrochir Plast Chir 1986;18:295-7 (in German).
    • (1986) Handchir. Mikrochir. Plast. Chir. , vol.18 , pp. 295-297
    • Haas, H.G.1
  • 3
    • 0023198604 scopus 로고
    • Biodegradable internal fixation for malleolar fractures: A prospective randomised trial
    • Bötman O, Vainionpää S, Hirvensalo E, at al. Biodegradable internal fixation for malleolar fractures: a prospective randomised trial. J Bone Joint Surg [Br] 1987;69-B: 615-19.
    • (1987) J. Bone Joint Surg. [Br.] , vol.69 B , pp. 615-619
    • Bötman, O.1    Vainionpää, S.2    Hirvensalo, E.3
  • 4
    • 0024835916 scopus 로고
    • Fracture fixation with biodegradable rods: Forty-one cases of severe ankle fractures
    • Hirvensalo E. Fracture fixation with biodegradable rods: forty-one cases of severe ankle fractures. Acta Orthop Scand 1989;60:601-6.
    • (1989) Acta Orthop. Scand. , vol.60 , pp. 601-606
    • Hirvensalo, E.1
  • 5
    • 0026473093 scopus 로고
    • Biodegradable rods versus Kirschner wire fixation of wrist fractures: A randomised trial
    • Casteleyn PP, Handelberg F, Haentjens P. Biodegradable rods versus Kirschner wire fixation of wrist fractures: a randomised trial. J Bone Joint Surg [Br] 1992;74-B: 858-61.
    • (1992) J. Bone Joint Surg. [Br.] , vol.74 B , pp. 858-861
    • Casteleyn, P.P.1    Handelberg, F.2    Haentjens, P.3
  • 7
    • 0027315403 scopus 로고
    • Arthroscopic shoulder stabilization: A role for biodegradable materials
    • Speer KP, Warren RF. Arthroscopic shoulder stabilization: a role for biodegradable materials. Clin Orthop 1993;291:67-4.
    • (1993) Clin. Orthop. , vol.291 , pp. 67-74
    • Speer, K.P.1    Warren, R.F.2
  • 8
    • 4143100182 scopus 로고    scopus 로고
    • Open Bankart repair versus arthrosopic repair with transglenoid sutures or bioabsorbable tacks for recurrent anterior instability of the shoulder: A meta-analysis
    • Freedman KB, Smith AP, Romeo AA, Cole BJ, Bach BR Jr. Open Bankart repair versus arthrosopic repair with transglenoid sutures or bioabsorbable tacks for recurrent anterior instability of the shoulder: a meta-analysis. Am J Sports Med 2004; 32:1520-7.
    • (2004) Am. J. Sports Med. , vol.32 , pp. 1520-1527
    • Freedman, K.B.1    Smith, A.P.2    Romeo, A.A.3    Cole, B.J.4    Bach Jr., B.R.5
  • 9
    • 0025334647 scopus 로고
    • Foreign-body reactions to fracture fixation implants of biodegradable synthetic polymers
    • Böstman O, Hirvensalo E, Mäkinen J, Rokkanen P. Foreign-body reactions to fracture fixation implants of biodegradable synthetic polymers. J Bone Joint Surg [Br] 1990;72-B:592-6.
    • (1990) J. Bone Joint Surg. [Br.] , vol.72 B , pp. 592-596
    • Böstman, O.1    Hirvensalo, E.2    Mäkinen, J.3    Rokkanen, P.4
  • 10
    • 0026575586 scopus 로고
    • Osteosynthesis of distal radial fractures with biodegradable fracture rods: Results of two years follow-up
    • (in German)
    • Hoffmann R, Krettek C, Hetkämper A, Haas N, Tscherne H. Osteosynthesis of distal radial fractures with biodegradable fracture rods: results of two years follow-up. Unfallchirurg 1992;95:99-105 (in German).
    • (1992) Unfallchirurg , vol.95 , pp. 99-105
    • Hoffmann, R.1    Krettek, C.2    Hetkämper, A.3    Haas, N.4    Tscherne, H.5
  • 11
    • 0028566614 scopus 로고
    • Foreign body reactions to absorbable implant fixation of osteotomies
    • Miketa JP, Prigoff MM. Foreign body reactions to absorbable implant fixation of osteotomies. J Foot Ankle Surg 1994;33:623-7.
    • (1994) J. Foot Ankle Surg. , vol.33 , pp. 623-627
    • Miketa, J.P.1    Prigoff, M.M.2
  • 12
    • 0026497098 scopus 로고
    • Self-reinforced absorbable screws in the fixation of displaced ankle fractures: A prospective clinical study of 152 patients
    • Partio EK, Böstman O, Hirvensalo E, et al. Self-reinforced absorbable screws in the fixation of displaced ankle fractures: a prospective clinical study of 152 patients. J Orthop Trauma Surg 1992;6:209-15.
    • (1992) J. Orthop. Trauma Surg. , vol.6 , pp. 209-215
    • Partio, E.K.1    Böstman, O.2    Hirvensalo, E.3
  • 14
    • 0027217152 scopus 로고
    • Polylactide screws in acetabular osteotomy: 28 dysplastic hips followed for 1 year
    • Nakamura S, Ninomiya S, Takatori Y. Polylactide screws in acetabular osteotomy: 28 dysplastic hips followed for 1 year. Acta Orthop Scand 1993;64:301-2.
    • (1993) Acta Orthop. Scand. , vol.64 , pp. 301-302
    • Nakamura, S.1    Ninomiya, S.2    Takatori, Y.3
  • 15
    • 0028593351 scopus 로고
    • Bioabsorbable osteosynthetic implants of ultra high strength poly-L-lactide: A clinical study
    • Yamamuro T, Matsusue Y, Uchida A, at al. Bioabsorbable osteosynthetic implants of ultra high strength poly-L-lactide: a clinical study. Int Orthop 1994;18:332-40.
    • (1994) Int. Orthop. , vol.18 , pp. 332-340
    • Yamamuro, T.1    Matsusue, Y.2    Uchida, A.3
  • 16
    • 0028316813 scopus 로고
    • Fixation with bioabsorbable screws for the treatment of fractures of the ankle
    • Bucholz RW, Henry S, Henley MB. Fixation with bioabsorbable screws for the treatment of fractures of the ankle. J Bone Joint Surg [Am] 1994;76-A:319-24.
    • (1994) J. Bone Joint Surg. [Am.] , vol.76 A , pp. 319-324
    • Bucholz, R.W.1    Henry, S.2    Henley, M.B.3
  • 17
    • 0027308691 scopus 로고
    • Foreign body reactions to resorbable poly(L-lactide) bone plates and screws used for the fixation of unstable zygomatic fractures
    • Bergsma EJ, Rozema FR, Bos RRM, de Bruiim WC. Foreign body reactions to resorbable poly(L-lactide) bone plates and screws used for the fixation of unstable zygomatic fractures. J Oral Maxillofac Surg 1993;51:666-70.
    • (1993) J. Oral Maxillofac. Surg. , vol.51 , pp. 666-670
    • Bergsma, E.J.1    Rozema, F.R.2    Bos, R.R.M.3    de Bruiim, W.C.4
  • 18
    • 0032444193 scopus 로고    scopus 로고
    • Late foreign-body reaction to an intraosseous bioabsorbable polylactic acid screw: A case report
    • Böstman OM, Pihlajamäki H. Late foreign-body reaction to an intraosseous bioabsorbable polylactic acid screw: a case report. J Bone Joint Surg [Am] 1998;80-A: 1791-4.
    • (1998) J. Bone Joint Surg. [Am.] , vol.80 A , pp. 1791-1794
    • Böstman, O.M.1    Pihlajamäki, H.2
  • 19
    • 0031970510 scopus 로고    scopus 로고
    • Foreign body gonitis caused by a broken poly-L-lactic acid screw
    • Takizawa T, Akizuki S, Horiuchi H, Yasukawa Y. Foreign body gonitis caused by a broken poly-L-lactic acid screw. Arthroscopy 1998;14:329-30.
    • (1998) Arthroscopy , vol.14 , pp. 329-330
    • Takizawa, T.1    Akizuki, S.2    Horiuchi, H.3    Yasukawa, Y.4
  • 20
    • 0035059546 scopus 로고    scopus 로고
    • Intraosseous bioabsorbable poly-L-lactide acid screw presenting as a late foreign-body reaction: A case report
    • Mosier-Laclair S, Pike H, Pomeroy G. Intraosseous bioabsorbable poly-L-lactide acid screw presenting as a late foreign-body reaction: a case report. Foot Ankle Int 2001;22:247-51.
    • (2001) Foot Ankle Int. , vol.22 , pp. 247-251
    • Mosier-Laclair, S.1    Pike, H.2    Pomeroy, G.3
  • 22
    • 4744353665 scopus 로고    scopus 로고
    • Delayed degradation of a meniscal screw
    • Willcox N, Roberts S. Delayed degradation of a meniscal screw. Arthroscopy 2004; 20(Suppl 2):20-2.
    • (2004) Arthroscopy , vol.20 , Issue.SUPPL. 2 , pp. 20-22
    • Willcox, N.1    Roberts, S.2
  • 23
    • 0026802462 scopus 로고
    • Degradation and tissue replacement of an absorbable polyglycolide screw in the fixation of rabbit femoral osteotomies
    • Böstman O, Päivärinta U, Partio E, at al. Degradation and tissue replacement of an absorbable polyglycolide screw in the fixation of rabbit femoral osteotomies. J Bone Joint Surg [Am] 1992;74-A:1021-31.
    • (1992) J. Bone Joint Surg. [Am.] , vol.74 A , pp. 1021-1031
    • Böstman, O.1    Päivärinta, U.2    Partio, E.3
  • 24
    • 0029891715 scopus 로고    scopus 로고
    • Foreign-body reaction and the course of osteolysis after polyglycolide implants for fracture fixation: Experimental study in sheep
    • Weiler A, Helling HJ, Kirch U, Zirbes TK, Rehm KE. Foreign-body reaction and the course of osteolysis after polyglycolide implants for fracture fixation: experimental study in sheep. J Bone Joint Surg [Br] 1996;78-B:369-76.
    • (1996) J. Bone Joint Surg. [Br.] , vol.78 B , pp. 369-376
    • Weiler, A.1    Helling, H.J.2    Kirch, U.3    Zirbes, T.K.4    Rehm, K.E.5
  • 25
    • 0346025467 scopus 로고    scopus 로고
    • Effects of polyglycolic acid bioabsorbable membrane and oxidised cellulose on the osteogenesis in bone defects: An experimental study
    • Askar I, Gultan SM, Erden E, Yormuk E. Effects of polyglycolic acid bioabsorbable membrane and oxidised cellulose on the osteogenesis in bone defects: an experimental study. Acta Chir Plast 2003;45:131-8.
    • (2003) Acta Chir. Plast. , vol.45 , pp. 131-138
    • Askar, I.1    Gultan, S.M.2    Erden, E.3    Yormuk, E.4
  • 26
    • 0024748292 scopus 로고
    • Bioabsorption of polylactides with different molecular properties
    • Nakamura T, Hitomi S, Watanabe S, at al. Bioabsorption of polylactides with different molecular properties. J Biomed Mater Res 1989;23:1115-30.
    • (1989) J. Biomed. Mater. Res. , vol.23 , pp. 1115-1130
    • Nakamura, T.1    Hitomi, S.2    Watanabe, S.3
  • 27
    • 0025971712 scopus 로고
    • Absorbable implants for the fixation of fractures
    • Böstman OM. Absorbable implants for the fixation of fractures. J Bone Joint Surg [Am] 1991;73-A:148-53.
    • (1991) J. Bone Joint Surg. [Am.] , vol.73 A , pp. 148-153
    • Böstman, O.M.1
  • 28
    • 0034446599 scopus 로고    scopus 로고
    • Bioresorbable polymers in trauma and bone surgery
    • Gogolewski S. Bioresorbable polymers in trauma and bone surgery. Injury 2000;31 (Suppl 4):28-32.
    • (2000) Injury , vol.31 , Issue.SUPPL. 4 , pp. 28-32
    • Gogolewski, S.1
  • 31
    • 0026071229 scopus 로고
    • Degradation of and tissue reaction to biodegradable poly(L-lactide) for use as internal fixation of fractures: A study in rats
    • Bos RRM, Rozema FR, Bearing G, at al. Degradation of and tissue reaction to biodegradable poly(L-lactide) for use as internal fixation of fractures: a study in rats. Biomaterials 1991;12:32-6.
    • (1991) Biomaterials , vol.12 , pp. 32-36
    • Bos, R.R.M.1    Rozema, F.R.2    Bearing, G.3
  • 33
    • 0026484791 scopus 로고
    • Polymeric debris from absorbable polyglycolide screws and pins: Intraosseous migration studies in rabbits
    • Böstman O, Päivärinta U, Manninen M, Rokkanen P. Polymeric debris from absorbable polyglycolide screws and pins: intraosseous migration studies in rabbits. Acta Orthop Scand 1992;63:555-9.
    • (1992) Acta Orthop. Scand. , vol.63 , pp. 555-559
    • Böstman, O.1    Päivärinta, U.2    Manninen, M.3    Rokkanen, P.4
  • 34
    • 0035998354 scopus 로고    scopus 로고
    • Transmission electron microscopic visualization of the degradation and phagocytosis of a poly-L-lactide screw in cancellous bone: A long-term experimental study
    • Laitinen O, Pihlajamaki H, Sukura A, Böstman O. Transmission electron microscopic visualization of the degradation and phagocytosis of a poly-L-lactide screw in cancellous bone: a long-term experimental study. J Biomed Mater Res 2002;61:33-9.
    • (2002) J. Biomed. Mater. Res. , vol.61 , pp. 33-39
    • Laitinen, O.1    Pihlajamaki, H.2    Sukura, A.3    Böstman, O.4
  • 36
    • 0028862442 scopus 로고
    • Clinical biocompatability and degradation of polylevolactide screws in the ankle
    • Böstman O, Pihlajamäki H, Partio EK, Rokkanen P. Clinical biocompatability and degradation of polylevolactide screws in the ankle. Clin Orthop 1995;320:101-9.
    • (1995) Clin. Orthop. , vol.320 , pp. 101-109
    • Böstman, O.1    Pihlajamäki, H.2    Partio, E.K.3    Rokkanen, P.4
  • 37
    • 0031681399 scopus 로고    scopus 로고
    • Delayed aseptic swelling after fixation of talar neck fracture with a biodegradable poly-L-lactide rod: Case reports
    • Yoshino N, Takai S, Watanabe Y, Kamata K, Hirasawa Y. Delayed aseptic swelling after fixation of talar neck fracture with a biodegradable poly-L-lactide rod: case reports. Foot Ankle Int 1998;19:634-7.
    • (1998) Foot Ankle Int. , vol.19 , pp. 634-637
    • Yoshino, N.1    Takai, S.2    Watanabe, Y.3    Kamata, K.4    Hirasawa, Y.5
  • 38
    • 0031262284 scopus 로고    scopus 로고
    • MR imaging of biodegradable poly-levolactide osteosynthesis devices in the ankle
    • Pihlajamäki H, Karjalainen P, Aronen H, Böstman O. MR imaging of biodegradable poly-levolactide osteosynthesis devices in the ankle. J Orthop Trauma 1997;11: 559-64.
    • (1997) J. Orthop. Trauma , vol.11 , pp. 559-564
    • Pihlajamäki, H.1    Karjalainen, P.2    Aronen, H.3    Böstman, O.4
  • 39
    • 0035413031 scopus 로고    scopus 로고
    • Bone tunnel remodeling at the site of biodegradable interference screws used for anterior cruciate ligament reconstruction: 5-year follow-up
    • Lajtai G, Schmiedhuber G, Unger F, at al. Bone tunnel remodeling at the site of biodegradable interference screws used for anterior cruciate ligament reconstruction: 5-year follow-up. Arthroscopy 2001;17:597-602.
    • (2001) Arthroscopy , vol.17 , pp. 597-602
    • Lajtai, G.1    Schmiedhuber, G.2    Unger, F.3
  • 40
    • 28444472112 scopus 로고    scopus 로고
    • Absorbable self-reinforced poly-L-lactic (SR-PLLA) acid pins fixation in metatarsal fractures: 3-year follow-up
    • Folliero A, Bondi L, Avitto A, Bellelli A. Absorbable self-reinforced poly-L-lactic (SR-PLLA) acid pins fixation in metatarsal fractures: 3-year follow-up. J Bone Joint Surg [Br] 2004:86-B(Suppl III):345.
    • (2004) J. Bone Joint Surg. [Br.] , vol.86 B , Issue.SUPPL. III , pp. 345
    • Folliero, A.1    Bondi, L.2    Avitto, A.3    Bellelli, A.4
  • 41
    • 0038051473 scopus 로고    scopus 로고
    • Adverse tissue reactions to bioabsorbable fixation devices
    • Böstman OM, Pihlajamäki HK. Adverse tissue reactions to bioabsorbable fixation devices. Clin Orthop 2000;371:216-27.
    • (2000) Clin. Orthop. , vol.371 , pp. 216-227
    • Böstman, O.M.1    Pihlajamäki, H.K.2
  • 42
    • 0025784686 scopus 로고
    • Osteolytic changes accompanying degradation of absorbable fracture fixation implants
    • Böstman OM. Osteolytic changes accompanying degradation of absorbable fracture fixation implants. J Bone Joint Surg [Br] 1991;73-B:679-82.
    • (1991) J. Bone Joint Surg. [Br.] , vol.73 B , pp. 679-682
    • Böstman, O.M.1
  • 43
    • 0026465553 scopus 로고
    • Osteolysis after biodegradable pin fixation of fractures in children
    • Fraser RK, Cole WG. Osteolysis after biodegradable pin fixation of fractures in children. J Bone Joint Surg [Br] 1992;74-B:929-30.
    • (1992) J. Bone Joint Surg. [Br.] , vol.74 B , pp. 929-930
    • Fraser, R.K.1    Cole, W.G.2
  • 44
    • 0030816290 scopus 로고    scopus 로고
    • A long-term clinical study on drawn poly-L-lactide implants in orthopaedic surgery
    • Matsusue Y, Nakamura T, Iida H, Shimizu K. A long-term clinical study on drawn poly-L-lactide implants in orthopaedic surgery. J Long Term Eff Med Implants 1997;7: 119-37.
    • (1997) J. Long Term Eff. Med. Implants , vol.7 , pp. 119-137
    • Matsusue, Y.1    Nakamura, T.2    Iida, H.3    Shimizu, K.4
  • 45
    • 0035092802 scopus 로고    scopus 로고
    • Osteolytic reaction to polyevolactic acid fracture fixation
    • Rovinsky D, Nissen TP, Otsuka NY. Osteolytic reaction to polyevolactic acid fracture fixation. Orthopedics 2001;24:177-9.
    • (2001) Orthopedics , vol.24 , pp. 177-179
    • Rovinsky, D.1    Nissen, T.P.2    Otsuka, N.Y.3
  • 46
    • 0036348607 scopus 로고    scopus 로고
    • Osteolysis after open shoulder-stabilization using a new bioresorbable bone anchor: A prospective, non-randomized clinical trial
    • Müller M, Kääb MJ, Villiger C, Holzach P. Osteolysis after open shoulder-stabilization using a new bioresorbable bone anchor: a prospective, non-randomized clinical trial. Injury 2002;33-B:30-6.
    • (2002) Injury , vol.33 B , pp. 30-36
    • Müller, M.1    Kääb, M.J.2    Villiger, C.3    Holzach, P.4
  • 47
    • 0347623805 scopus 로고    scopus 로고
    • Osteoarthritis of the ankle after foreign-body reaction to absorbable pins and screws: A three-to nine-yeaY follow-up study
    • Böstman OM. Osteoarthritis of the ankle after foreign-body reaction to absorbable pins and screws: a three-to nine-yeaY follow-up study. J Bone Joint Surg [Br] 1998; 80-B:333-8.
    • (1998) J. Bone Joint Surg. [Br.] , vol.80 B , pp. 333-338
    • Böstman, O.M.1
  • 48
    • 0032956450 scopus 로고    scopus 로고
    • Failure of a biodegradable meniscal arrow: A case report
    • Hutchinson MR, Ash SA. Failure of a biodegradable meniscal arrow: a case report. Am J Sports Med 1999;27:101-3.
    • (1999) Am. J. Sports Med. , vol.27 , pp. 101-103
    • Hutchinson, M.R.1    Ash, S.A.2
  • 49
    • 0642307109 scopus 로고    scopus 로고
    • Biodegradable screw presents as a loose intra-articular body after anterior cruciate ligament reconstruction
    • Macdonald P, Arneja S. Biodegradable screw presents as a loose intra-articular body after anterior cruciate ligament reconstruction. Arthroscopy 2003;19:22-4.
    • (2003) Arthroscopy , vol.19 , pp. 22-24
    • Macdonald, P.1    Arneja, S.2
  • 50
    • 3042842475 scopus 로고    scopus 로고
    • Self-reinforced poly-lactide/polyglycolide 80/20 screws take more than 1 (1/2) years to resorb in rabbit cranial bone
    • Tiainen J, Soini Y, Törmälä P, Waris T, Ashammakhi N. Self-reinforced poly-lactide/polyglycolide 80/20 screws take more than 1 (1/2) years to resorb in rabbit cranial bone. J Biomed Mat Res 2004;70:49-55.
    • (2004) J. Biomed. Mat. Res. , vol.70 , pp. 49-55
    • Tiainen, J.1    Soini, Y.2    Törmälä, P.3    Waris, T.4    Ashammakhi, N.5
  • 51
    • 11144272811 scopus 로고    scopus 로고
    • Fixation of osteochondritis dissecans lesions using poly(l-lactic-acid)/poly(glycolic acid) copolymer bioabsorbable screws
    • Larsen MW, Pietrzak WS, Delee JC. Fixation of osteochondritis dissecans lesions using poly(l-lactic-acid)/poly(glycolic acid) copolymer bioabsorbable screws. Am J Sports Med 2005;33:68-76.
    • (2005) Am. J. Sports Med. , vol.33 , pp. 68-76
    • Larsen, M.W.1    Pietrzak, W.S.2    Delee, J.C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.