메뉴 건너뛰기




Volumn 62, Issue 6, 2005, Pages 638-643

Recurrent aortoenteric fistula: Case report and review

Author keywords

Aortic diseases; Gastrointestinal hemorrhage; Intestinal fistula; Postoperative complications; Vascular fistula

Indexed keywords

AGED; AORTOINTESTINAL FISTULA; ARTIFICIAL VENTILATION; CASE REPORT; CLINICAL FEATURE; ERYTHROCYTE TRANSFUSION; FEMALE; FEVER; FOLLOW UP; GASTROINTESTINAL ENDOSCOPY; GASTROINTESTINAL HEMORRHAGE; GASTROTOMY; HEMATOCRIT; HUMAN; HYPOTENSION; INTENSIVE CARE UNIT; INTUBATION; MORBIDITY; OPERATION DURATION; PERCUTANEOUS DRAINAGE; POSTOPERATIVE PERIOD; PRIORITY JOURNAL; RECURRENT DISEASE; REVIEW; SPLEEN ABSCESS; SURGICAL TECHNIQUE; TREATMENT OUTCOME; VASCULAR SURGERY;

EID: 28344454995     PISSN: 01497944     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.cursur.2005.03.022     Document Type: Article
Times cited : (21)

References (45)
  • 3
    • 0036227898 scopus 로고    scopus 로고
    • Aortoenteric fistula in advanced germ cell tumor: A rare lethal complication
    • K.S. Hansen R.C. Sheley Aortoenteric fistula in advanced germ cell tumor: A rare lethal complication J Urol 167 2002 2131
    • (2002) J. Urol. , vol.167 , pp. 2131
    • Hansen, K.S.1    Sheley, R.C.2
  • 4
    • 0035209333 scopus 로고    scopus 로고
    • Diagnosis and management of aortoenteric fistulas
    • S.J. Busuttil J. Goldstone Diagnosis and management of aortoenteric fistulas Semin Vasc Surg 14 2001 302-311
    • (2001) Semin. Vasc. Surg. , vol.14 , pp. 302-311
    • Busuttil, S.J.1    Goldstone, J.2
  • 5
    • 0029831134 scopus 로고    scopus 로고
    • The surgical management of aortoenteric fistulas
    • R.S. Montgomery S.E. Wilson The surgical management of aortoenteric fistulas Surg Clin North Am 76 1996 1147-1157
    • (1996) Surg. Clin. North Am. , vol.76 , pp. 1147-1157
    • Montgomery, R.S.1    Wilson, S.E.2
  • 7
    • 0027408346 scopus 로고
    • Primary aortoduodenal fistula: A unique presentation of a pseudoaneurysm associated with cystic medial necrosis
    • J.A. Rhim R.A. Rubin D.A. Katzka G.G. Pietra Primary aortoduodenal fistula: A unique presentation of a pseudoaneurysm associated with cystic medial necrosis Am J Gastroenterol 88 1993 447-450
    • (1993) Am. J. Gastroenterol. , vol.88 , pp. 447-450
    • Rhim, J.A.1    Rubin, R.A.2    Katzka, D.A.3    Pietra, G.G.4
  • 8
    • 0030010644 scopus 로고    scopus 로고
    • Primary aortoenteric fistula from a posttraumatic pseudoaneurysm
    • P.J. Napoli P.C. Meade C.W. Adams Primary aortoenteric fistula from a posttraumatic pseudoaneurysm J Trauma 41 1 1996 149-152
    • (1996) J. Trauma , vol.41 , Issue.1 , pp. 149-152
    • Napoli, P.J.1    Meade, P.C.2    Adams, C.W.3
  • 9
    • 0036337628 scopus 로고    scopus 로고
    • Aortoduodenal fistula in the acute trauma setting: Case report
    • A. Nothmann T. Tung B. Simon Aortoduodenal fistula in the acute trauma setting: Case report J Trauma 53 1 2002 106-108
    • (2002) J. Trauma , vol.53 , Issue.1 , pp. 106-108
    • Nothmann, A.1    Tung, T.2    Simon, B.3
  • 10
    • 0037344264 scopus 로고    scopus 로고
    • Primary aortoduodenal fistula: A case report and review of the literature
    • D.W. Lemos J.D. Raffetto T.C. Moore J.O. Menzoian Primary aortoduodenal fistula: A case report and review of the literature J Vasc Surg 37 2003 686-689
    • (2003) J. Vasc. Surg. , vol.37 , pp. 686-689
    • Lemos, D.W.1    Raffetto, J.D.2    Moore, T.C.3    Menzoian, J.O.4
  • 11
    • 0018344517 scopus 로고
    • Pathogenesis of aortoduodenal fistula: Experimental and clinical correlates
    • R.W. Busuttil W. Rees J.D. Baker S.E. Wilson Pathogenesis of aortoduodenal fistula: Experimental and clinical correlates Surgery 85 1 1979 1-13
    • (1979) Surgery , vol.85 , Issue.1 , pp. 1-13
    • Busuttil, R.W.1    Rees, W.2    Baker, J.D.3    Wilson, S.E.4
  • 12
    • 0031781152 scopus 로고    scopus 로고
    • Aortoenteric fistula caused by a ruptured stent-graft: A case report
    • L. Norgren B. Jernby L. Engellau Aortoenteric fistula caused by a ruptured stent-graft: A case report J Endovasc Surg 5 1998 269-272
    • (1998) J. Endovasc. Surg. , vol.5 , pp. 269-272
    • Norgren, L.1    Jernby, B.2    Engellau, L.3
  • 13
    • 0033984860 scopus 로고    scopus 로고
    • Aortoduodenal fistula after endovascular stent-graft of an abdominal aortic aneurysm
    • B. Janne d'Othee P. Soula P. Otal et al. Aortoduodenal fistula after endovascular stent-graft of an abdominal aortic aneurysm J Vasc Surg 31 1 pt 1 2000 190-195
    • (2000) J. Vasc. Surg. , vol.31 , Issue.1 PART 1 , pp. 190-195
    • Janne d'Othee, B.1    Soula, P.2    Otal, P.3
  • 14
    • 0037326104 scopus 로고    scopus 로고
    • Aortoduodenal fistula and associated rupture of abdominal aortic aneurysm after endoluminal stent graft repair
    • S. Alankar M.H. Barth D.D. Shin J.R. Hong W.R. Rosenberg Aortoduodenal fistula and associated rupture of abdominal aortic aneurysm after endoluminal stent graft repair J Vasc Surg 37 2003 465-468
    • (2003) J. Vasc. Surg. , vol.37 , pp. 465-468
    • Alankar, S.1    Barth, M.H.2    Shin, D.D.3    Hong, J.R.4    Rosenberg, W.R.5
  • 15
    • 0037329017 scopus 로고    scopus 로고
    • Aortoduodenal fistula occurring after type II endoleak treatment with coil embolization of the aortic sac
    • S. Elkouri J.F. Blair E. Therasse L. Oliva L. Bruneau G. Soulez Aortoduodenal fistula occurring after type II endoleak treatment with coil embolization of the aortic sac J Vasc Surg 37 2003 461-464
    • (2003) J. Vasc. Surg. , vol.37 , pp. 461-464
    • Elkouri, S.1    Blair, J.F.2    Therasse, E.3    Oliva, L.4    Bruneau, L.5    Soulez, G.6
  • 16
    • 0021284640 scopus 로고
    • Primary aortoduodenal fistula: Manifestation, diagnosis, and treatment
    • M.S. Sweeney T.R. Gadacz Primary aortoduodenal fistula: Manifestation, diagnosis, and treatment Surgery 96 1984 492-497
    • (1984) Surgery , vol.96 , pp. 492-497
    • Sweeney, M.S.1    Gadacz, T.R.2
  • 17
    • 0023475094 scopus 로고
    • Gastrointestinal hemorrhage due to fistula from aortic aneurysm
    • C.L. Mollerup L. Strand Gastrointestinal hemorrhage due to fistula from aortic aneurysm Acta Chir Scand 153 1987 631-632
    • (1987) Acta Chir. Scand. , vol.153 , pp. 631-632
    • Mollerup, C.L.1    Strand, L.2
  • 19
    • 0031035563 scopus 로고    scopus 로고
    • Images in clinical medicine. Aortoenteric fistula
    • W. Abernethy J.H. Sekijima Images in clinical medicine. Aortoenteric fistula N Eng J Med 336 1997 1 27
    • (1997) N. Eng. J. Med. , vol.336 , Issue.1 , pp. 27
    • Abernethy, W.1    Sekijima, J.H.2
  • 20
    • 0030762803 scopus 로고    scopus 로고
    • Aortoduodenal fistula: Appearances on computed tomography
    • C.A. Daly D.M. Nott S.P. Padley Aortoduodenal fistula: Appearances on computed tomography Aust N Z J Surg 67 1997 745-746
    • (1997) Aust. N. Z. J. Surg. , vol.67 , pp. 745-746
    • Daly, C.A.1    Nott, D.M.2    Padley, S.P.3
  • 21
    • 2342661186 scopus 로고    scopus 로고
    • Multidetector computed tomography imaging of aortoenteric fistula
    • F.J. Perks I. Gillespie D. Patel Multidetector computed tomography imaging of aortoenteric fistula J Comput Assist Tomogr 28 2004 343-347
    • (2004) J. Comput. Assist. Tomogr. , vol.28 , pp. 343-347
    • Perks, F.J.1    Gillespie, I.2    Patel, D.3
  • 22
    • 0034870890 scopus 로고    scopus 로고
    • Aortoenteric fistula complicating an infected aortic graft: Diagnosis by leukocyte scintigraphy
    • R.H. Ganatra M.A. Haniffa A.B. Hawthorne J.I. Rees Aortoenteric fistula complicating an infected aortic graft: Diagnosis by leukocyte scintigraphy Clin Nucl Med 26 2001 800-801
    • (2001) Clin. Nucl. Med. , vol.26 , pp. 800-801
    • Ganatra, R.H.1    Haniffa, M.A.2    Hawthorne, A.B.3    Rees, J.I.4
  • 24
    • 0030012448 scopus 로고    scopus 로고
    • Aortic balloon control of a traumatic aortoenteric fistula after damage control laparotomy: A case report
    • C.W. Schwab D.J. McMahon G. Phillips M.J. Pentecost Aortic balloon control of a traumatic aortoenteric fistula after damage control laparotomy: A case report J Trauma 40 1996 1021-1023
    • (1996) J. Trauma , vol.40 , pp. 1021-1023
    • Schwab, C.W.1    McMahon, D.J.2    Phillips, G.3    Pentecost, M.J.4
  • 26
    • 0032772947 scopus 로고    scopus 로고
    • In situ replacement of infected aortic grafts with rifampin-bonded prostheses: The Leicester experience 1992-1998
    • P.D. Hayes A. Nasim N.J. London et al. In situ replacement of infected aortic grafts with rifampin-bonded prostheses: The Leicester experience 1992-1998 J Vasc Surg 30 1999 1 92-98
    • (1999) J. Vasc. Surg. , vol.30 , Issue.1 , pp. 92-98
    • Hayes, P.D.1    Nasim, A.2    London, N.J.3
  • 27
    • 0033645568 scopus 로고    scopus 로고
    • Use of cryopreserved arterial homografts for management of infected prosthetic grafts: A multicentric study
    • R. Verhelst V. Lacroix H. Vraux et al. Use of cryopreserved arterial homografts for management of infected prosthetic grafts: A multicentric study Ann Vasc Surg 14 2000 602-607
    • (2000) Ann. Vasc. Surg. , vol.14 , pp. 602-607
    • Verhelst, R.1    Lacroix, V.2    Vraux, H.3
  • 30
    • 0032853707 scopus 로고    scopus 로고
    • The results of in situ prosthetic replacement for infected aortic grafts
    • R.M. Young K.J. Cherry Jr M.P. Davis et al. The results of in situ prosthetic replacement for infected aortic grafts Am J Surg 178 1999 136-140
    • (1999) Am. J. Surg. , vol.178 , pp. 136-140
    • Young, R.M.1    Cherry Jr., K.J.2    Davis, M.P.3
  • 31
    • 0023226807 scopus 로고
    • The management of aortoduodenal fistula by in situ replacement of the infected abdominal aortic graft
    • W.E. Walker D.A. Cooley J.M. Duncan G.L. Hallman Jr D.A. Ott G.J. Reul The management of aortoduodenal fistula by in situ replacement of the infected abdominal aortic graft Ann Surg 205 1987 727-732
    • (1987) Ann. Surg. , vol.205 , pp. 727-732
    • Walker, W.E.1    Cooley, D.A.2    Duncan, J.M.3    Hallman Jr., G.L.4    Ott, D.A.5    Reul, G.J.6
  • 32
    • 0019441506 scopus 로고
    • Secondary aortoenteric fistula. A 20 year experience
    • C.S. O'Mara G.M. Williams C.B. Ernst Secondary aortoenteric fistula. A 20 year experience Am J Surg 142 1981 203-209
    • (1981) Am. J. Surg. , vol.142 , pp. 203-209
    • O'Mara, C.S.1    Williams, G.M.2    Ernst, C.B.3
  • 33
    • 0037409843 scopus 로고    scopus 로고
    • Aorto-enteric fistula is a serious complication to aortic surgery. modern trends in diagnosis and therapy
    • J. Sierra A. Kalangos B. Faidutti J.T. Christenson Aorto-enteric fistula is a serious complication to aortic surgery. modern trends in diagnosis and therapy Cardiovasc Surg 11 2003 185-188
    • (2003) Cardiovasc. Surg. , vol.11 , pp. 185-188
    • Sierra, J.1    Kalangos, A.2    Faidutti, B.3    Christenson, J.T.4
  • 35
    • 0023471941 scopus 로고
    • Secondary aortoenteric fistulas - An analysis of 42 cases
    • D. Bergqvist A. Alm G. Claes et al. Secondary aortoenteric fistulas - an analysis of 42 cases Eur J Vasc Surg 1 1 1987 11-18
    • (1987) Eur. J. Vasc. Surg. , vol.1 , Issue.1 , pp. 11-18
    • Bergqvist, D.1    Alm, A.2    Claes, G.3
  • 36
    • 0025075294 scopus 로고
    • Recurrent aorto-duodenal fistula: A final solution?
    • D.W. England M.H. Simms Recurrent aorto-duodenal fistula: A final solution? Eur J Vasc Surg 4 1990 427-429
    • (1990) Eur. J. Vasc. Surg. , vol.4 , pp. 427-429
    • England, D.W.1    Simms, M.H.2
  • 37
    • 0020104867 scopus 로고
    • Recurrent aortoduodenal fistula: A lesson in management
    • S.L. Hill L.H. Knott R.H. Alexander Recurrent aortoduodenal fistula: A lesson in management Am Surg 48 1982 137-140
    • (1982) Am. Surg. , vol.48 , pp. 137-140
    • Hill, S.L.1    Knott, L.H.2    Alexander, R.H.3
  • 40
    • 0033867345 scopus 로고    scopus 로고
    • Stent-graft treatment for bleeding from a presumed aortoenteric fistula
    • A.J. Grabs C.D. Irvine R.J. Lusby Stent-graft treatment for bleeding from a presumed aortoenteric fistula J Endovasc Ther 7 2000 236-239
    • (2000) J. Endovasc. Ther. , vol.7 , pp. 236-239
    • Grabs, A.J.1    Irvine, C.D.2    Lusby, R.J.3
  • 41
    • 0036054587 scopus 로고    scopus 로고
    • Emergent treatment of a primary aortoenteric fistula with N-butyl 2-cyanoacrylate and endovascular stent
    • L. Finch R.B. Heathcock T. Quigley G. Jiranek D. Robinson Emergent treatment of a primary aortoenteric fistula with N-butyl 2-cyanoacrylate and endovascular stent J Vasc Interv Radiol 13 2002 841-843
    • (2002) J. Vasc. Interv. Radiol. , vol.13 , pp. 841-843
    • Finch, L.1    Heathcock, R.B.2    Quigley, T.3    Jiranek, G.4    Robinson, D.5
  • 42
    • 0018524105 scopus 로고
    • Primary aortoduodenal fistula: Extra-anatomic vascular reconstruction not required for successful management
    • M. Daugherty G.R. Shearer C.B. Ernst Primary aortoduodenal fistula: extra-anatomic vascular reconstruction not required for successful management Surgery 86 1979 399-401
    • (1979) Surgery , vol.86 , pp. 399-401
    • Daugherty, M.1    Shearer, G.R.2    Ernst, C.B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.