메뉴 건너뛰기




Volumn , Issue , 2004, Pages

A high performance compression algorithm for ECG with irregular periods

Author keywords

[No Author keywords available]

Indexed keywords

ALGORITHMS; ARRAYS; CORRELATION METHODS; ELECTROCARDIOGRAPHY;

EID: 28244474872     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (6)

References (17)
  • 1
    • 0033011358 scopus 로고    scopus 로고
    • ECG data compression using cut and align beats approach and 2-D transforms
    • H. Lee and K. M. Buckley, "ECG data compression using cut and align beats approach and 2-D transforms", IEEE Trans. Biomed. Eng., vol. 46, pp. 556-565, 1999.
    • (1999) IEEE Trans. Biomed. Eng. , vol.46 , pp. 556-565
    • Lee, H.1    Buckley, K.M.2
  • 2
    • 0027655722 scopus 로고
    • ECG compression using long-term prediction
    • G. Nave and A. Cohen, "ECG compression using long-term prediction", IEEE Trans. Biomed. Eng., vol. 40, pp. 877-885, 1993.
    • (1993) IEEE Trans. Biomed. Eng. , vol.40 , pp. 877-885
    • Nave, G.1    Cohen, A.2
  • 3
    • 0031193987 scopus 로고    scopus 로고
    • Compression of ECG data by vector quantization
    • B. Wang and G. Yuan, "Compression of ECG data by vector quantization", IEEE Trans. Biomed. Eng., vol. 40, pp. 23-26, 1997.
    • (1997) IEEE Trans. Biomed. Eng. , vol.40 , pp. 23-26
    • Wang, B.1    Yuan, G.2
  • 4
    • 0035530508 scopus 로고    scopus 로고
    • ECG data compression using truncated singular value decomposition
    • J. J. Wei, C. J. Chang, N. K. Chou, and G. J. Jan, "ECG data compression using truncated singular value decomposition", IEEE Trans. Biomed. Eng., vol. 5, pp. 290-299, 2001.
    • (2001) IEEE Trans. Biomed. Eng. , vol.5 , pp. 290-299
    • Wei, J.J.1    Chang, C.J.2    Chou, N.K.3    Jan, G.J.4
  • 5
    • 0036129958 scopus 로고    scopus 로고
    • An efficient coding algorithm for the compression of ECG signals using the wavelet transform
    • B. A. Rajoub, "An efficient coding algorithm for the compression of ECG signals using the wavelet transform", IEEE Trans. Biomed. Eng., vol. 49, pp. 355-362, 2002.
    • (2002) IEEE Trans. Biomed. Eng. , vol.49 , pp. 355-362
    • Rajoub, B.A.1
  • 6
    • 0030947878 scopus 로고    scopus 로고
    • Wavelet and wavelet packet compression of electrocardiograms
    • M. L. Hilton, "Wavelet and wavelet packet compression of electrocardiograms", IEEE Trans. Biomed. Eng., vol. 44, pp. 394-402, 1997.
    • (1997) IEEE Trans. Biomed. Eng. , vol.44 , pp. 394-402
    • Hilton, M.L.1
  • 7
    • 28244457457 scopus 로고    scopus 로고
    • A two dimensional wavelet packet approach for ECG compression
    • the 6th International, Symposium
    • A. R. A. Moghaddam and K. Nayebi, "A two dimensional wavelet packet approach for ECG compression", Signal Processing and its Applications, the 6th International, Symposium, pp. 226-229, 2001.
    • (2001) Signal Processing and Its Applications , pp. 226-229
    • Moghaddam, A.R.A.1    Nayebi, K.2
  • 8
    • 0014274098 scopus 로고
    • AZTEC: Pre processing program for real-time ECG rhythm analysis
    • J. R. Cox, F. M. Noile, H. A. Fozzard, and G. C. Olover, "AZTEC: pre processing program for real-time ECG rhythm analysis", IEEE Trans. Biomed. Eng., vol. 15, pp. 128-129, 1968.
    • (1968) IEEE Trans. Biomed. Eng. , vol.15 , pp. 128-129
    • Cox, J.R.1    Noile, F.M.2    Fozzard, H.A.3    Olover, G.C.4
  • 9
    • 0020850377 scopus 로고
    • Scan-along polygonal approximation for data compression of electrocardiograms
    • M. Ishijima, S. B. Shin, G. H. Hostetter, and J. Sklansky, "Scan-along polygonal approximation for data compression of electrocardiograms," IEEE Trans. Biomed. Eng., vol. 30, 11, pp. 723-729, 1983.
    • (1983) IEEE Trans. Biomed. Eng. , vol.30 , Issue.11 , pp. 723-729
    • Ishijima, M.1    Shin, S.B.2    Hostetter, G.H.3    Sklansky, J.4
  • 10
    • 0024273950 scopus 로고
    • Adaptive sampling of cardiac waveforms
    • R. C. Barr, "Adaptive sampling of cardiac waveforms", J. Electrocard., 21, pp. 57-60, 1988.
    • (1988) J. Electrocard. , vol.21 , pp. 57-60
    • Barr, R.C.1
  • 13
    • 2642532202 scopus 로고    scopus 로고
    • Wavelet compression of ECG signals by JPEG2000
    • DCC2004, Mar.
    • A. Bilgin, M. W. Marcellin, and M. I. Altbach, "Wavelet compression of ECG signals by JPEG2000", Conf. Data Compression, DCC2004, pp. 527-527, Mar. 2004.
    • (2004) Conf. Data Compression , pp. 527-527
    • Bilgin, A.1    Marcellin, M.W.2    Altbach, M.I.3
  • 15
    • 0030316093 scopus 로고    scopus 로고
    • A simple real-time QRS detection algorithm
    • J. Lee, K. Jeong, J. Yoon, and M. Lee, "A simple real-time QRS detection algorithm", IEEE Proc. Biomed. Eng., vol. 4, pp. 1396-1398, 1996.
    • (1996) IEEE Proc. Biomed. Eng. , vol.4 , pp. 1396-1398
    • Lee, J.1    Jeong, K.2    Yoon, J.3    Lee, M.4
  • 17
    • 28244483415 scopus 로고
    • Harvard-MIT Division of Health Sciences and Technology, Aug.
    • "MIT-BIH Arrhythmia Database CD-ROM", 2nd. Ed., Harvard-MIT Division of Health Sciences and Technology, Aug. 1992.
    • (1992) "MIT-BIH Arrhythmia Database CD-ROM", 2nd. Ed.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.