메뉴 건너뛰기




Volumn 34, Issue 4, 2005, Pages 345-352

Short-term aseptic loosening of the femoral component in canine total hip replacement: Effects of cementing technique on cement mantle grade

Author keywords

Aseptic loosening; Cement mantle grade; Cementing technique; Dog; Total hip replacement

Indexed keywords

BONE CEMENT;

EID: 28144449530     PISSN: 01613499     EISSN: 1532950X     Source Type: Journal    
DOI: 10.1111/j.1532-950X.2005.00053.x     Document Type: Review
Times cited : (33)

References (41)
  • 2
    • 0021104437 scopus 로고
    • A five year study of 221 total hip replacements in the dog
    • Olmstead ML, Hohn RB, Turner TM: A five year study of 221 total hip replacements in the dog. J Am Vet Med Assoc 183:191-195, 1983
    • (1983) J Am Vet Med Assoc , vol.183 , pp. 191-195
    • Olmstead, M.L.1    Hohn, R.B.2    Turner, T.M.3
  • 3
    • 0028489980 scopus 로고
    • Clinical and radiographic results of total hip arthroplasty in dogs: 96 cases (1986-1992)
    • Massat BJ, Vasseur PB: Clinical and radiographic results of total hip arthroplasty in dogs: 96 cases (1986-1992). J Am Vet Med Assoc 205:448-454, 1994
    • (1994) J Am Vet Med Assoc , vol.205 , pp. 448-454
    • Massat, B.J.1    Vasseur, P.B.2
  • 4
    • 0029266837 scopus 로고
    • The canine cemented modular total hip prosthesis
    • Olmstead ML: The canine cemented modular total hip prosthesis. J Am Anim Hosp Assoc 31:109-123, 1995
    • (1995) J Am Anim Hosp Assoc , vol.31 , pp. 109-123
    • Olmstead, M.L.1
  • 5
    • 0034321610 scopus 로고    scopus 로고
    • Evaluation of risk factor for luxation after total hip replacement in dogs
    • Dyce J, Wisner ER, Wang Q, et al: Evaluation of risk factor for luxation after total hip replacement in dogs. Vet Surg 29:524-532, 2000
    • (2000) Vet Surg , vol.29 , pp. 524-532
    • Dyce, J.1    Wisner, E.R.2    Wang, Q.3
  • 6
    • 0031226596 scopus 로고    scopus 로고
    • Aseptic loosening of the femoral implant after cemented total hip arthroplasty in dogs: 11 Cases in 10 dogs (1991-1995)
    • Edwards MR, Egger EL, Schwarz PD: Aseptic loosening of the femoral implant after cemented total hip arthroplasty in dogs: 11 cases in 10 dogs (1991-1995). J Am Vet Med Assoc 211:580-586, 1997
    • (1997) J Am Vet Med Assoc , vol.211 , pp. 580-586
    • Edwards, M.R.1    Egger, E.L.2    Schwarz, P.D.3
  • 7
    • 0019962848 scopus 로고
    • A ten-year follow-up of one hundred consecutive Müller curved-stem total hip-replacement arthroplasties
    • Sutherland CJ, Wilde AH, Borden LS, et al: A ten-year follow-up of one hundred consecutive Müller curved-stem total hip-replacement arthroplasties. J Bone Joint Surg 64-A:970-982, 1982
    • (1982) J Bone Joint Surg , vol.64 A , pp. 970-982
    • Sutherland, C.J.1    Wilde, A.H.2    Borden, L.S.3
  • 8
    • 0017805913 scopus 로고
    • Total hip arthroplasty: A review of 333 cases with long follow-up
    • Beckenbaugh RD, Ilstrup DM: Total hip arthroplasty: a review of 333 cases with long follow-up. J Bone Joint Surg 60-A:306-313, 1978
    • (1978) J Bone Joint Surg , vol.60 A , pp. 306-313
    • Beckenbaugh, R.D.1    Ilstrup, D.M.2
  • 9
    • 0018867441 scopus 로고
    • Mechanical loosening of the femoral head prosthesis in the Charnley Total Hip Arthroplasty
    • Carlsson AS, Gentz CF: Mechanical loosening of the femoral head prosthesis in the Charnley Total Hip Arthroplasty. Clin Orthop Relat Res 147:262-270, 1980
    • (1980) Clin Orthop Relat Res , vol.147 , pp. 262-270
    • Carlsson, A.S.1    Gentz, C.F.2
  • 10
    • 0026317891 scopus 로고
    • Mechanical properties of bone cement
    • Linden U: Mechanical properties of bone cement. Clin Orthop Relat Res 272:274-278, 1991
    • (1991) Clin Orthop Relat Res , vol.272 , pp. 274-278
    • Linden, U.1
  • 11
    • 0029052858 scopus 로고
    • Factors influencing pressurization of the femoral canal during cemented total hip arthroplasty
    • Maltry JA, Noble PC, Kamaric E, et al: Factors influencing pressurization of the femoral canal during cemented total hip arthroplasty. J Arthroplasty 10:492-497, 1995
    • (1995) J Arthroplasty , vol.10 , pp. 492-497
    • Maltry, J.A.1    Noble, P.C.2    Kamaric, E.3
  • 12
    • 0023686316 scopus 로고
    • Modern use of modern cement for total hip replacement
    • Harris WH, Davies JP: Modern use of modern cement for total hip replacement. Orthop Clin North Am 19:581-589, 1988
    • (1988) Orthop Clin North Am , vol.19 , pp. 581-589
    • Harris, W.H.1    Davies, J.P.2
  • 13
    • 0032406608 scopus 로고    scopus 로고
    • Femoral cementing techniques in total hip replacement
    • Rice J, Prenderville T, Murray P, et al: Femoral cementing techniques in total hip replacement. Int Orthop 22:308-311, 1998
    • (1998) Int Orthop , vol.22 , pp. 308-311
    • Rice, J.1    Prenderville, T.2    Murray, P.3
  • 14
    • 0025161599 scopus 로고
    • The effect of improved cementing techniques on component loosening in total hip replacement
    • Mulroy RD, Harris WH: The effect of improved cementing techniques on component loosening in total hip replacement. J Bone Joint Surg 72-B:757-760, 1990
    • (1990) J Bone Joint Surg , vol.72 B , pp. 757-760
    • Mulroy, R.D.1    Harris, W.H.2
  • 15
    • 0028810966 scopus 로고
    • Results of cemented femoral revision total hip arthroplasty using improved cementing techniques
    • Katz RP, Callaghan JJ, Sullivan PM, et al: Results of cemented femoral revision total hip arthroplasty using improved cementing techniques. Clin Orthop Relat Res 319:178-183, 1995
    • (1995) Clin Orthop Relat Res , vol.319 , pp. 178-183
    • Katz, R.P.1    Callaghan, J.J.2    Sullivan, P.M.3
  • 16
    • 0022966284 scopus 로고
    • Loosening of the femoral component after use of the medullary-plug cementing technique
    • Harris WH, McGann WA: Loosening of the femoral component after use of the medullary-plug cementing technique. J. Bone Joint Surg 68-A:1064-1066, 1986
    • (1986) J. Bone Joint Surg , vol.68 A , pp. 1064-1066
    • Harris, W.H.1    McGann, W.A.2
  • 17
    • 0026495786 scopus 로고
    • Factors influencing survivorship of the femoral component after primary low-friction hip arthroplasty
    • Kobayashi S, Terayama K: Factors influencing survivorship of the femoral component after primary low-friction hip arthroplasty. J Arthroplasty 7:327-338, 1992
    • (1992) J Arthroplasty , vol.7 , pp. 327-338
    • Kobayashi, S.1    Terayama, K.2
  • 18
    • 0021717803 scopus 로고
    • Centrifugation as a method of improving tensile and fatigue properties of acrylic bone cement
    • Burke DW, Gates EI, Harris WH: Centrifugation as a method of improving tensile and fatigue properties of acrylic bone cement. J Bone Joint Surg 66-A:1265-1273, 1984
    • (1984) J Bone Joint Surg , vol.66 A , pp. 1265-1273
    • Burke, D.W.1    Gates, E.I.2    Harris, W.H.3
  • 19
    • 0036023503 scopus 로고    scopus 로고
    • Differences in bone-cement porosity by vacuum mixing, centrifugation, and hand mixing
    • Macaulay W, DiGiovanni CW, Restrepo A, et al: Differences in bone-cement porosity by vacuum mixing, centrifugation, and hand mixing. J Arthroplasty 17:569-575, 2002
    • (2002) J Arthroplasty , vol.17 , pp. 569-575
    • Macaulay, W.1    DiGiovanni, C.W.2    Restrepo, A.3
  • 20
    • 0023875026 scopus 로고
    • The effect of centrifugation on the fatigue life of bone cement in the presence of surface irregularities
    • Davies JP, O'Connor DO, Burke DW, et al: The effect of centrifugation on the fatigue life of bone cement in the presence of surface irregularities. Clin Orthop Relat Res 229:156-161, 1988
    • (1988) Clin Orthop Relat Res , vol.229 , pp. 156-161
    • Davies, J.P.1    O'Connor, D.O.2    Burke, D.W.3
  • 21
    • 0026527960 scopus 로고
    • Improved cementing techniques and femoral component loosening in young patients with hip arthroplasty
    • Barrack RL, Mulroy RD, Harris WH: Improved cementing techniques and femoral component loosening in young patients with hip arthroplasty. J Bone Joint Surg 74-B:385-389, 1992
    • (1992) J Bone Joint Surg , vol.74 B , pp. 385-389
    • Barrack, R.L.1    Mulroy, R.D.2    Harris, W.H.3
  • 22
    • 0016256315 scopus 로고
    • Factors in the mechanical failure of the femoral component in total hip prosthesis
    • Martens M, Aernoudt E, De Meester P, et al: Factors in the mechanical failure of the femoral component in total hip prosthesis. Acta Orthop Scand 45:693-710, 1974
    • (1974) Acta Orthop Scand , vol.45 , pp. 693-710
    • Martens, M.1    Aernoudt, E.2    De Meester, P.3
  • 23
    • 0025784682 scopus 로고
    • The initiation of failure in cementing femoral components of hip arthroplasties
    • Jasty M, Maloney WJ, Bragdon CR, et al: The initiation of failure in cementing femoral components of hip arthroplasties. J Bone Joint Surg 73-A:551-558, 1991
    • (1991) J Bone Joint Surg , vol.73 A , pp. 551-558
    • Jasty, M.1    Maloney, W.J.2    Bragdon, C.R.3
  • 24
    • 0026864135 scopus 로고
    • A fractographic investigation of PMMA bone cement focusing on the relationship between porosity reduction and increased fatigue life
    • James S, Jasty M, Davies J, et al: A fractographic investigation of PMMA bone cement focusing on the relationship between porosity reduction and increased fatigue life. J Biomed Mater Res 26:651-662, 1992
    • (1992) J Biomed Mater Res , vol.26 , pp. 651-662
    • James, S.1    Jasty, M.2    Davies, J.3
  • 25
    • 0023388405 scopus 로고
    • Cementing technique and the effects of bleeding
    • Benjamin JB, Gie GA, Lee AJC, et al: Cementing technique and the effects of bleeding. J Bone Joint Surg 69-B:620-624, 1987
    • (1987) J Bone Joint Surg , vol.69 B , pp. 620-624
    • Benjamin, J.B.1    Gie, G.A.2    Lee, A.J.C.3
  • 26
    • 0018104415 scopus 로고
    • Improved fixation of the femoral component after total hip replacement using a methacrylate intramedullary plug
    • Oh E, Carlson CE, Tomford WW, et al: Improved fixation of the femoral component after total hip replacement using a methacrylate intramedullary plug. J Bone Joint Surg 60-A:608-613, 1978
    • (1978) J Bone Joint Surg , vol.60 A , pp. 608-613
    • Oh, E.1    Carlson, C.E.2    Tomford, W.W.3
  • 27
    • 0031238588 scopus 로고    scopus 로고
    • Effect of mixing method on selected properties of acrylic bone cement
    • Lewis G, Nyman JS, Trieu HH: Effect of mixing method on selected properties of acrylic bone cement. J Biomed Mater Res 38:221-228, 1997
    • (1997) J Biomed Mater Res , vol.38 , pp. 221-228
    • Lewis, G.1    Nyman, J.S.2    Trieu, H.H.3
  • 29
    • 0028034860 scopus 로고
    • Does early micromotion of femoral stem prostheses matter? 4-7 Year stereoradiographic follow up of 84 cemented prosthesies
    • Karrholm J, Borssen B, Lowenhielm G, et al: Does early micromotion of femoral stem prostheses matter? 4-7 year stereoradiographic follow up of 84 cemented prosthesies. J Bone Joint Surg 76-B:912-917, 1994
    • (1994) J Bone Joint Surg , vol.76 B , pp. 912-917
    • Karrholm, J.1    Borssen, B.2    Lowenhielm, G.3
  • 30
    • 0028282143 scopus 로고
    • Early migration and late aseptic failure of proximal femoral prosthesis
    • Freeman MA, Plante-Bordeneuve P: Early migration and late aseptic failure of proximal femoral prosthesis. J Bone Joint Surg 76-B:432-438, 1994
    • (1994) J Bone Joint Surg , vol.76 B , pp. 432-438
    • Freeman, M.A.1    Plante-Bordeneuve, P.2
  • 31
    • 0026605414 scopus 로고
    • Mechanism and clinical significance of wear debris-induced osteolysis
    • Amstutz HC, Campbell P, Kossovsky N, et al: Mechanism and clinical significance of wear debris-induced osteolysis. Clin Orthop Relat Res 276:7-15, 1992
    • (1992) Clin Orthop Relat Res , vol.276 , pp. 7-15
    • Amstutz, H.C.1    Campbell, P.2    Kossovsky, N.3
  • 32
    • 0026577202 scopus 로고
    • Metallic debris in femoral endosteolysis in failed cemented total hip arthroplasties
    • Huo MH, Salvati EA, Lieberman JR, et al: Metallic debris in femoral endosteolysis in failed cemented total hip arthroplasties. Clin Orthop Relat Res 157-168, 1992
    • (1992) Clin Orthop Relat Res , pp. 157-168
    • Huo, M.H.1    Salvati, E.A.2    Lieberman, J.R.3
  • 33
    • 0025348266 scopus 로고
    • Aggressive granulomatous lesions associated with hip arthroplasty: Immunopathological studies
    • Santavirta S, Kontinen YT, Berbroth V, et al: Aggressive granulomatous lesions associated with hip arthroplasty: immunopathological studies. J. Bone Joint Surg 72-A:252-258, 1990
    • (1990) J. Bone Joint Surg , vol.72 A , pp. 252-258
    • Santavirta, S.1    Kontinen, Y.T.2    Berbroth, V.3
  • 34
    • 0031863827 scopus 로고    scopus 로고
    • Femoral cement grading in total hip arthroplasty
    • Harvey EJ, Tanzer M, Bobyn JD: Femoral cement grading in total hip arthroplasty. J Arthroplasty 13:396-401, 1998
    • (1998) J Arthroplasty , vol.13 , pp. 396-401
    • Harvey, E.J.1    Tanzer, M.2    Bobyn, J.D.3
  • 35
    • 0029929408 scopus 로고    scopus 로고
    • Radiological evaluation of the interfaces after cemented total hip replacement
    • McCaskie AW, Brown AR, Thompson JR, et al: Radiological evaluation of the interfaces after cemented total hip replacement. J Bone Joint Surg 78-B:191-194, 1996
    • (1996) J Bone Joint Surg , vol.78 B , pp. 191-194
    • McCaskie, A.W.1    Brown, A.R.2    Thompson, J.R.3
  • 36
    • 0029886006 scopus 로고    scopus 로고
    • Inter- and intraobserver study of radiographic assessment of cemented total hip arthroplasties
    • Kramhøft M, Gehrchen PM, Bødtker S, et al: Inter- and intraobserver study of radiographic assessment of cemented total hip arthroplasties. J Arthroplasty 11:272-276, 1996
    • (1996) J Arthroplasty , vol.11 , pp. 272-276
    • Kramhøft, M.1    Gehrchen, P.M.2    Bødtker, S.3
  • 37
    • 0020568125 scopus 로고
    • Factors associated with early loosening of cemented total hip prostheses
    • Hierton C, Blomgren G, Lindogren U: Factors associated with early loosening of cemented total hip prostheses. Acta Orthop Scand 54:168-173, 1983
    • (1983) Acta Orthop Scand , vol.54 , pp. 168-173
    • Hierton, C.1    Blomgren, G.2    Lindogren, U.3
  • 38
    • 2342454311 scopus 로고    scopus 로고
    • Postmortem retrieved canine THR: Femoral and acetabular component interaction
    • Skurla CP, James SP: Postmortem retrieved canine THR: femoral and acetabular component interaction. Biomed Sci Instrum 40:255-260, 2004
    • (2004) Biomed Sci Instrum , vol.40 , pp. 255-260
    • Skurla, C.P.1    James, S.P.2
  • 39
    • 0018877406 scopus 로고
    • The effect of femoral stem cross-sectional geometry on cement stresses in total hip reconstruction
    • Crowninshield RD, Brand RA, Johnston RC, et al: The effect of femoral stem cross-sectional geometry on cement stresses in total hip reconstruction. Clin Orthop 146:71-77, 1980
    • (1980) Clin Orthop , vol.146 , pp. 71-77
    • Crowninshield, R.D.1    Brand, R.A.2    Johnston, R.C.3
  • 41
    • 0021355275 scopus 로고
    • Femoral cement pressurization during total hip arthroplasty. The role of different femoral stems with reference to stem size and shape
    • Bourne RB, Oh I, Harris WH: Femoral cement pressurization during total hip arthroplasty. The role of different femoral stems with reference to stem size and shape. Clin Orthop 183:12-16, 1984
    • (1984) Clin Orthop , vol.183 , pp. 12-16
    • Bourne, R.B.1    Oh, I.2    Harris, W.H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.