-
1
-
-
0028085655
-
The role of sonography in the placement and management of jugular and subclavian central venous catheters
-
Skolnick ML: The role of sonography in the placement and management of jugular and subclavian central venous catheters. Am J Roentgenol 1994; 163:291-5
-
(1994)
Am J Roentgenol
, vol.163
, pp. 291-295
-
-
Skolnick, M.L.1
-
2
-
-
0345451017
-
US-guided puncture of the internal jugular vein: Complications and anatomic considerations
-
Gordon AC, Saliken JC, Johns D, Owen R, Gray RR: US-guided puncture of the internal jugular vein: Complications and anatomic considerations. J Vasc Interv Radiol 1998; 9:333-8
-
(1998)
J Vasc Interv Radiol
, vol.9
, pp. 333-338
-
-
Gordon, A.C.1
Saliken, J.C.2
Johns, D.3
Owen, R.4
Gray, R.R.5
-
3
-
-
0031769125
-
Sonographic guidance when using the right internal jugular vein for central vein access
-
Caridi JG, Hawkins IF Jr, Wiechmann BN, Pevarski DJ, Tonkin JC: Sonographic guidance when using the right internal jugular vein for central vein access. Am J Roentgenol 1998; 171:1259-63
-
(1998)
Am J Roentgenol
, vol.171
, pp. 1259-1263
-
-
Caridi, J.G.1
Hawkins Jr., I.F.2
Wiechmann, B.N.3
Pevarski, D.J.4
Tonkin, J.C.5
-
4
-
-
0029956197
-
Ultrasound monitoring in cannulation of the internal jugular vein: Anatomic and technical considerations
-
Docktor B, So CB, Saliken JC, Gray RR: Ultrasound monitoring in cannulation of the internal jugular vein: Anatomic and technical considerations. Can Assoc Radiol J 1996; 47:195-201
-
(1996)
Can Assoc Radiol J
, vol.47
, pp. 195-201
-
-
Docktor, B.1
So, C.B.2
Saliken, J.C.3
Gray, R.R.4
-
6
-
-
0036288586
-
Use of ultrasound to place central lines
-
Keenan SP: Use of ultrasound to place central lines. J Crit Care 2002; 17:126-37
-
(2002)
J Crit Care
, vol.17
, pp. 126-137
-
-
Keenan, S.P.1
-
9
-
-
0031779341
-
An evaluation of the factors influencing selection of the optimal size of laryngeal mask airway in normal adults
-
Berry AM, Brimacombe JR, McManus KF, Goldblatt M: An evaluation of the factors influencing selection of the optimal size of laryngeal mask airway in normal adults. Anaesthesia 1998; 53:565-70
-
(1998)
Anaesthesia
, vol.53
, pp. 565-570
-
-
Berry, A.M.1
Brimacombe, J.R.2
McManus, K.F.3
Goldblatt, M.4
-
10
-
-
0031943954
-
Appropriate size and inflation of the laryngeal mask airway
-
Asai T, Howell TK, Koga K, Morris S: Appropriate size and inflation of the laryngeal mask airway. Br J Anaesth 1998; 80:470-4
-
(1998)
Br J Anaesth
, vol.80
, pp. 470-474
-
-
Asai, T.1
Howell, T.K.2
Koga, K.3
Morris, S.4
-
12
-
-
0003360386
-
Noninvasive cardiovascular monitoring
-
Edited by Saidman, LJ Smith NT. San Diego, Butterworth-Heinemann
-
Perrino AC Jr, Feldman J, Barash PG: Noninvasive cardiovascular monitoring, Monitoring in Anesthesia, 3rd edition. Edited by Saidman, LJ Smith NT. San Diego, Butterworth-Heinemann, 1993, pp 64
-
(1993)
Monitoring in Anesthesia, 3rd Edition
, pp. 64
-
-
Perrino Jr., A.C.1
Feldman, J.2
Barash, P.G.3
-
15
-
-
0030036024
-
Optimal infracuff pressures with the laryngeal mask
-
Brimacombe J, Berry A, Brain AIJ: Optimal infracuff pressures with the laryngeal mask. Br J Anaesth 1996; 77:295-6
-
(1996)
Br J Anaesth
, vol.77
, pp. 295-296
-
-
Brimacombe, J.1
Berry, A.2
Brain, A.I.J.3
-
16
-
-
0030029633
-
Head rotation during internal jugular vein cannulation and the risk of carotid artery puncture
-
Sulek CA, Gravenstein N, Blackshear RH, Weiss L: Head rotation during internal jugular vein cannulation and the risk of carotid artery puncture. Anesth Analg 1996; 82:125-8
-
(1996)
Anesth Analg
, vol.82
, pp. 125-128
-
-
Sulek, C.A.1
Gravenstein, N.2
Blackshear, R.H.3
Weiss, L.4
-
17
-
-
0031030950
-
The effect of laryngeal mask airway insertion on the position of the internal jugular vein
-
Nandwani N, Fairfield MC, Krarup K, Thompson J: The effect of laryngeal mask airway insertion on the position of the internal jugular vein. Anaesthesia 1997; 52:77-83
-
(1997)
Anaesthesia
, vol.52
, pp. 77-83
-
-
Nandwani, N.1
Fairfield, M.C.2
Krarup, K.3
Thompson, J.4
-
18
-
-
4644252264
-
Optimal head rotation for internal jugular vein cannulation when relying on external landmarks
-
Lieberman JA, Williams KA, Rosenberg AL: Optimal head rotation for internal jugular vein cannulation when relying on external landmarks. Anesth Analg 2004; 99:982-8
-
(2004)
Anesth Analg
, vol.99
, pp. 982-988
-
-
Lieberman, J.A.1
Williams, K.A.2
Rosenberg, A.L.3
-
19
-
-
0028216303
-
Neutral head position for placement of internal jugular vein catheters
-
Willeford KL, Reitan JA: Neutral head position for placement of internal jugular vein catheters. Anaesthesia 1994; 49:202-4
-
(1994)
Anaesthesia
, vol.49
, pp. 202-204
-
-
Willeford, K.L.1
Reitan, J.A.2
-
20
-
-
0030057294
-
Internal jugular vein and carotid artery anatomic relation as determined by ultrasonography
-
Troianos CA, Kuwik RJ, Pasqual JR, Lim AJ, Odasso DP: Internal jugular vein and carotid artery anatomic relation as determined by ultrasonography. ANESTHESIOLOGY 1996; 85:43-8
-
(1996)
Anesthesiology
, vol.85
, pp. 43-48
-
-
Troianos, C.A.1
Kuwik, R.J.2
Pasqual, J.R.3
Lim, A.J.4
Odasso, D.P.5
-
21
-
-
0024312696
-
Simultaneous aortic, jugular bulb, and right atrial pressures during cardiopulmonary resuscitation in humans: Insights into mechanism
-
Paradis NA, Martin GB, Goetting MG, Rosenberg JM, Rivers EP, Appleton TJ, Nowak RM: Simultaneous aortic, jugular bulb, and right atrial pressures during cardiopulmonary resuscitation in humans: Insights into mechanism. Circulation 1989; 80:361-8
-
(1989)
Circulation
, vol.80
, pp. 361-368
-
-
Paradis, N.A.1
Martin, G.B.2
Goetting, M.G.3
Rosenberg, J.M.4
Rivers, E.P.5
Appleton, T.J.6
Nowak, R.M.7
-
22
-
-
2542575477
-
Trendelenburg position, head elevation and a midline position optimize right internal jugular vein diameter
-
Parry G: Trendelenburg position, head elevation and a midline position optimize right internal jugular vein diameter. Can J Anesth 2004; 51:379-81
-
(2004)
Can J Anesth
, vol.51
, pp. 379-381
-
-
Parry, G.1
-
23
-
-
0026337972
-
Anatomical variations of internal jugular vein location: Impact on central venous access
-
Denys BG, Uretsky BF: Anatomical variations of internal jugular vein location: Impact on central venous access. Crit Care Med 1991; 19:1516-9
-
(1991)
Crit Care Med
, vol.19
, pp. 1516-1519
-
-
Denys, B.G.1
Uretsky, B.F.2
-
24
-
-
0028269032
-
The effect of position and different manoeuvres on internal jugular vein diameter size
-
Armstrong PJ, Sutherland R, Scott DHT: The effect of position and different manoeuvres on internal jugular vein diameter size. Acta Anaesth Scand 1994; 38:229-31
-
(1994)
Acta Anaesth Scand
, vol.38
, pp. 229-231
-
-
Armstrong, P.J.1
Sutherland, R.2
Scott, D.H.T.3
-
25
-
-
0242269043
-
Comparison of the LMA-Classic™ with the new disposable soft seal laryngeal mask in spontaneously breathing adult patients
-
Van Zundert AAJ, Fonck K, Al-Shaikh B, Mortier E: Comparison of the LMA-Classic™ with the new disposable soft seal laryngeal mask in spontaneously breathing adult patients. ANESTHESIOLOGY 2003; 99:1066-71
-
(2003)
Anesthesiology
, vol.99
, pp. 1066-1071
-
-
Van Zundert, A.A.J.1
Fonck, K.2
Al-Shaikh, B.3
Mortier, E.4
-
26
-
-
0033636120
-
Cuff volume and size selection with the laryngeal mask
-
Asai T, Brimacombe J: Cuff volume and size selection with the laryngeal mask. Anaesthesia 2000; 55:1179-84
-
(2000)
Anaesthesia
, vol.55
, pp. 1179-1184
-
-
Asai, T.1
Brimacombe, J.2
-
27
-
-
3342967581
-
A comparison of sex- and weight-based Proseal™ laryngeal mask size selection criteria
-
Kihara S, Brimacombe JR, Yaguchi Y, Taguchi N, Watanabe S: A comparison of sex- and weight-based Proseal™ laryngeal mask size selection criteria. ANESTHESIOLOGY 2004; 101:340-3
-
(2004)
Anesthesiology
, vol.101
, pp. 340-343
-
-
Kihara, S.1
Brimacombe, J.R.2
Yaguchi, Y.3
Taguchi, N.4
Watanabe, S.5
|