메뉴 건너뛰기




Volumn 32, Issue 11, 2005, Pages 3246-3256

Treatment delivery software for a new clinical grade ultrasound system for thermoradiotherapy

Author keywords

3D power deposition control; Failure mode and effects analysis; Frequency blending; Hyperthermia applicator; Medical software safety; Scanned ultrasound; Simultaneous thermoradiotherapy; Superficial tumors; Treatment delivery software; Ultrasonic heating

Indexed keywords

APPLICATORS; BLENDING; COMPUTER SOFTWARE SELECTION AND EVALUATION; DEPOSITION; HYPERTHERMIA THERAPY; OUTAGES; POWER CONTROL; REFLECTION; SAFETY ENGINEERING; SOFTWARE DESIGN; SOFTWARE TESTING; THERMOCOUPLES; ULTRASONICS;

EID: 28044450152     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.2064848     Document Type: Article
Times cited : (9)

References (31)
  • 1
    • 0031048617 scopus 로고    scopus 로고
    • An investigation of penetration depth control using parallel opposed ultrasound arrays and a scanning reflector
    • E. G. Moros, X. Fan, and W. L. Straube, "An investigation of penetration depth control using parallel opposed ultrasound arrays and a scanning reflector," J. Acoust. Soc. Am. 101, 1734-1741 (1997).
    • (1997) J. Acoust. Soc. Am. , vol.101 , pp. 1734-1741
    • Moros, E.G.1    Fan, X.2    Straube, W.L.3
  • 2
    • 0032962313 scopus 로고    scopus 로고
    • Experimental assessment of power and temperature penetration depth control, with a dual frequency ultrasonic system
    • E. G. Moros, X. Fan, and W. L. Straube, "Experimental assessment of power and temperature penetration depth control, with a dual frequency ultrasonic system," Med. Phys. 26, 810-817 (1999).
    • (1999) Med. Phys. , vol.26 , pp. 810-817
    • Moros, E.G.1    Fan, X.2    Straube, W.L.3
  • 3
    • 0028944536 scopus 로고
    • Simultaneous delivery of electron beam therapy and ultrasound hyperthermia using scanning reflectors: A feasibility study
    • E. G. Moros, W. L. Straube, E. E. Klein, M. Yousaf, and R. J. Myerson, "Simultaneous delivery of electron beam therapy and ultrasound hyperthermia using scanning reflectors: A feasibility study," Int. J. Radiat. Oncol., Biol., Phys. 31, 893-904 (1995).
    • (1995) Int. J. Radiat. Oncol., Biol., Phys. , vol.31 , pp. 893-904
    • Moros, E.G.1    Straube, W.L.2    Klein, E.E.3    Yousaf, M.4    Myerson, R.J.5
  • 5
    • 0029801164 scopus 로고    scopus 로고
    • Potential for power deposition conformability using reflected-scanned planar ultrasound
    • E. G. Moros, W. L. Straube, and R. J. Myerson, "Potential for power deposition conformability using reflected-scanned planar ultrasound," Int. J. Hyperthermia 12, 723-736 (1996).
    • (1996) Int. J. Hyperthermia , vol.12 , pp. 723-736
    • Moros, E.G.1    Straube, W.L.2    Myerson, R.J.3
  • 6
    • 0031849342 scopus 로고    scopus 로고
    • Numerical and in vitro evaluation of temperature fluctuations during reflected-scanned planar ultrasound hyperthermia
    • E. G. Moros, X. Fan, W. L. Straube, and R. J. Myerson, "Numerical and in vitro evaluation of temperature fluctuations during reflected-scanned planar ultrasound hyperthermia," Int. J. Hyperthermia 14, 367-382 (1998).
    • (1998) Int. J. Hyperthermia , vol.14 , pp. 367-382
    • Moros, E.G.1    Fan, X.2    Straube, W.L.3    Myerson, R.J.4
  • 7
    • 12844257366 scopus 로고    scopus 로고
    • SURLAS: A new clinical grade ultrasound system for sequential or concomitant thermoradiotherapy of superficial tumors: Applicator description
    • P. Novak, E. G. Moros, W. L. Straube, and R. J. Myerson, "SURLAS: A new clinical grade ultrasound system for sequential or concomitant thermoradiotherapy of superficial tumors: Applicator description," Med. Phys. 32, 230-240 (2005).
    • (2005) Med. Phys. , vol.32 , pp. 230-240
    • Novak, P.1    Moros, E.G.2    Straube, W.L.3    Myerson, R.J.4
  • 8
    • 0035175969 scopus 로고    scopus 로고
    • Dosimetry and techniques for simultaneous hyperthermia and external beam radiation therapy
    • W. L. Straube, E. E. Klein, E. G. Moros, D. A. Low, and R. J. Myerson, "Dosimetry and techniques for simultaneous hyperthermia and external beam radiation therapy," Int. J. Hyperthermia 17, 48-62 (2001).
    • (2001) Int. J. Hyperthermia , vol.17 , pp. 48-62
    • Straube, W.L.1    Klein, E.E.2    Moros, E.G.3    Low, D.A.4    Myerson, R.J.5
  • 10
    • 0032773531 scopus 로고    scopus 로고
    • Simultaneous superficial hyperthermia and external radiotherapy: Report of thermal dosimetry and tolerance to treatment
    • R. J. Myerson, W. L. Straube, E. G. Moros, B. N. Emami, H. K. Lee, C. A. Perez, and M. E. Taylor, "Simultaneous superficial hyperthermia and external radiotherapy: Report of thermal dosimetry and tolerance to treatment," Int. J. Hyperthermia 15, 251-266 (1999).
    • (1999) Int. J. Hyperthermia , vol.15 , pp. 251-266
    • Myerson, R.J.1    Straube, W.L.2    Moros, E.G.3    Emami, B.N.4    Lee, H.K.5    Perez, C.A.6    Taylor, M.E.7
  • 11
    • 0031944237 scopus 로고    scopus 로고
    • Writing software for the clinic
    • I. I. Rosen, "Writing software for the clinic," Med. Phys. 25, 301-309 (1998).
    • (1998) Med. Phys. , vol.25 , pp. 301-309
    • Rosen, I.I.1
  • 14
    • 85027220308 scopus 로고    scopus 로고
    • Human factors points to consider for IDE devices
    • U.S. Food and Drug Administration, Rockville, MD
    • "Human factors points to consider for IDE devices," in Human Factors IDE Enclosure (U.S. Food and Drug Administration, Rockville, MD, 1996), http://www.fda.gov/cdrh/humfac/ide_hf.html
    • (1996) Human Factors IDE Enclosure
  • 21
    • 0036470012 scopus 로고    scopus 로고
    • Body of knowledge for software quality measurement
    • N. F. Schneidewind, "Body of knowledge for software quality measurement," Computer 35, 77-83 (2002).
    • (2002) Computer , vol.35 , pp. 77-83
    • Schneidewind, N.F.1
  • 22
    • 0037618908 scopus 로고    scopus 로고
    • Assuring software quality assurance
    • J. Voas, "Assuring software quality assurance," IEEE Software 20, 48-49 (2003).
    • (2003) IEEE Software , vol.20 , pp. 48-49
    • Voas, J.1
  • 24
    • 0008427747 scopus 로고    scopus 로고
    • EIA/JEDEC Publication No. 131 Electronic Industries Association, Arlington, VA
    • Process Failure Mode and Effects Analysis (FMEA). EIA/JEDEC Publication No. 131 (Electronic Industries Association, Arlington, VA, 1998).
    • (1998) Process Failure Mode and Effects Analysis (FMEA)
  • 25
    • 0042235280 scopus 로고    scopus 로고
    • The role of inspection in software quality assurance
    • D. L. Parnas and M. Lawford, "The role of inspection in software quality assurance," IEEE Trans. Software Eng. 29, 674-676 (2003).
    • (2003) IEEE Trans. Software Eng. , vol.29 , pp. 674-676
    • Parnas, D.L.1    Lawford, M.2
  • 30
    • 0033302717 scopus 로고    scopus 로고
    • Engineering aspects of hyperthermia therapy
    • R. B. Roemer, "Engineering aspects of hyperthermia therapy," Annu. Rev. Biomed. Eng. 1, 347-376 (1999).
    • (1999) Annu. Rev. Biomed. Eng. , vol.1 , pp. 347-376
    • Roemer, R.B.1
  • 31
    • 0031965484 scopus 로고    scopus 로고
    • Research and development of hyperthermia machines for present and future clinical needs
    • H. Kato, T. Koyama, Y. Nikawa, and M. Saito, "Research and development of hyperthermia machines for present and future clinical needs," Int. J. Hyperthermia 14, 1-11 (1998).
    • (1998) Int. J. Hyperthermia , vol.14 , pp. 1-11
    • Kato, H.1    Koyama, T.2    Nikawa, Y.3    Saito, M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.