Volumn 32, Issue 11, 2005, Pages 3279-3285

Dose rate constant of a Cesium-131 interstitial brachytherapy seed measured by thermoluminescent dosimetry and gamma-ray spectrometry

Author keywords

Brachytherapy dosimetry; Cesium 131; Dose rate constant; Gamma ray spectrometry; Photon energy spectrum; Thermoluminescent dosimetry

Indexed keywords

CESIUM; DOSIMETRY; GAMMA RAY SPECTROMETERS; MANUFACTURE; ONCOLOGY; PHOTONS; RADIOTHERAPY; RATE CONSTANTS; SPECTROMETRY; SPECTROSCOPY;

EID: 28044438934     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.2098127     Document Type: Article
Times cited : (27)

References (23)
  • 1
    • 85092679312 scopus 로고    scopus 로고
    • 131Cs product information sheet and company website
    • 131Cs product information sheet and company website http://www.isoray.com/
  • 2
    • 0005211821 scopus 로고    scopus 로고
    • Brookhaven National Laboratory. Database Last Updated on 12 August
    • R. R. Kinsey, "The NuDat Program for Nuclear Data on the Web," National Nuclear Data Center, Brookhaven National Laboratory. (http://www.nndc.bnl.gov/nndc/nudat/). Database Last Updated on 12 August 1999.
    • (1999) The NuDat Program for Nuclear Data on the Web
    • Kinsey, R.R.1
  • 3
    • 0028919251 scopus 로고
    • Dosimetry of interstitial brachytherapy sources: Recommendations of the AAPM Radiation Therapy Committee Task Group No. 43
    • R. Nath, L. L. Anderson, G. Luxton, K. A. Weaver, J. F. Williamson, and A. S. Meigooni, "Dosimetry of interstitial brachytherapy sources: Recommendations of the AAPM Radiation Therapy Committee Task Group No. 43," Med. Phys. 22, 209-234 (1995).
    • (1995) Med. Phys. , vol.22 , pp. 209-234
    • Nath, R.1    Anderson, L.L.2    Luxton, G.3    Weaver, K.A.4    Williamson, J.F.5    Meigooni, A.S.6
  • 4
    • 0037298130 scopus 로고    scopus 로고
    • The determination of radiobologically optimized half-lives for radionuclides used in permanent brachytherapy implants
    • C. I. Armpilia, R. G. Dale, I. P. Coles, B. Jones, and V. Antipas, "The determination of radiobologically optimized half-lives for radionuclides used in permanent brachytherapy implants," Int. J. Radiat. Oncol., Biol., Phys. 55, 378-385 (2003).
    • (2003) Int. J. Radiat. Oncol., Biol., Phys. , vol.55 , pp. 378-385
    • Armpilia, C.I.1    Dale, R.G.2    Coles, I.P.3    Jones, B.4    Antipas, V.5
  • 7
    • 0035142091 scopus 로고    scopus 로고
    • Dose rate constant and energy spectrum of interstitial brachytherapy sources
    • Z. Chen and R. Nath, "Dose rate constant and energy spectrum of interstitial brachytherapy sources" Med. Phys. 28, 86-96 (2001)
    • (2001) Med. Phys. , vol.28 , pp. 86-96
    • Chen, Z.1    Nath, R.2
  • 9
    • 0025221904 scopus 로고
    • Dosimetry on the transverse axis of 125I and 192Ir interstitial brachytherapy sources
    • R. Nath, A. S. Meigooni, and J. A. Meli, "Dosimetry on the transverse axis of 125I and 192Ir interstitial brachytherapy sources," Med. Phys. 17, 1032-1040 (1990).
    • (1990) Med. Phys. , vol.17 , pp. 1032-1040
    • Nath, R.1    Meigooni, A.S.2    Meli, J.A.3
  • 10
    • 0028235964 scopus 로고    scopus 로고
    • Comparison of radiation dosimetry in water and in solid phantom materials for I-125 and Pd-103 brachytherapy sources: EGS4 Monte Carlo study
    • G. Luxton, "Comparison of radiation dosimetry in water and in solid phantom materials for I-125 and Pd-103 brachytherapy sources: EGS4 Monte Carlo study," Med. Phys. 21, 631-641 (1999).
    • (1999) Med. Phys. , vol.21 , pp. 631-641
    • Luxton, G.1
  • 11
    • 0025900734 scopus 로고
    • Comparison of measured and calculated dose rates in water near I-125 and Ir-192 seeds
    • J. F. Williamson, "Comparison of measured and calculated dose rates in water near I-125 and Ir-192 seeds," Med. Phys. 18, 776-786 (1991).
    • (1991) Med. Phys. , vol.18 , pp. 776-786
    • Williamson, J.F.1
  • 12
    • 0021062111 scopus 로고
    • A protocol for the determination of absorbed dose from high-energy photon and electron beams: Report of the AAPM Radiation Therapy Committee Task Group 21
    • R. J. Schulz et al., "A protocol for the determination of absorbed dose from high-energy photon and electron beams: Report of the AAPM Radiation Therapy Committee Task Group 21," Med. Phys. 10, 741-771 (1983).
    • (1983) Med. Phys. , vol.10 , pp. 741-771
    • Schulz, R.J.1
  • 13
    • 0023717249 scopus 로고
    • A comparison of solid phantoms with water for dosimetry of 125I brachytherapy sources
    • A. S. Meigooni, J. A. Meli, and R. Nath, "A comparison of solid phantoms with water for dosimetry of 125I brachytherapy sources," Med. Phys. 15, 695-701 (1988).
    • (1988) Med. Phys. , vol.15 , pp. 695-701
    • Meigooni, A.S.1    Meli, J.A.2    Nath, R.3
  • 15
    • 0021453826 scopus 로고
    • Exposure standardization of iodine-125 seeds used fro brachytherapy
    • T. P. Loftus, "Exposure standardization of iodine-125 seeds used fro brachytherapy," J. Res. Natl. Bur. Stand. 89, 295-303 (1984).
    • (1984) J. Res. Natl. Bur. Stand. , vol.89 , pp. 295-303
    • Loftus, T.P.1
  • 17
  • 18
    • 0025904558 scopus 로고
    • Accurate Monte Carlo calculations of the combined attenuation and build-up factors, for energies (20-1500 keV) and distances (0-10 cm) relevant in brachytherapy
    • A. Angelopoulos, A. Perris, K. Sakellarious, L. Sakelliou, K. Sarigiannis, and G. Zarris, "Accurate Monte Carlo calculations of the combined attenuation and build-up factors, for energies (20-1500 keV) and distances (0-10 cm) relevant in brachytherapy," Phys. Med. Biol. 36, 763-778 (1991).
    • (1991) Phys. Med. Biol. , vol.36 , pp. 763-778
    • Angelopoulos, A.1    Perris, A.2    Sakellarious, K.3    Sakelliou, L.4    Sarigiannis, K.5    Zarris, G.6
  • 19
    • 0021703395 scopus 로고
    • 125I photons
    • 125I photons," Med. Phys. 11, 850-854 (1984).
    • (1984) Med. Phys. , vol.11 , pp. 850-854
    • Weaver, K.A.1
  • 20
    • 85092678762 scopus 로고    scopus 로고
    • note
    • 192Ir sources, as presented in Ref. 11. The 1.048 value was adopted by the AAPM Task Group 43 as described in the last paragraph on p. 232 of Ref. 3.
  • 21
    • 0033805914 scopus 로고    scopus 로고
    • Experimental determination of dosimetric characteristics of best 125I brachytherapy source
    • A. S. Meigooni, D. M. Gearheart, and K. Sowards, "Experimental determination of dosimetric characteristics of best 125I brachytherapy source," Med. Phys. 27, 2168-2173 (2000).
    • (2000) Med. Phys. , vol.27 , pp. 2168-2173
    • Meigooni, A.S.1    Gearheart, D.M.2    Sowards, K.3
  • 23
    • 0032873680 scopus 로고    scopus 로고
    • Report on the dosimetry of a new design 125Iodine brachytherapy source
    • R. E. Wallace and J. J. Fan, "Report on the dosimetry of a new design 125Iodine brachytherapy source," Med. Phys. 26, 1925-1931 (1999).
    • (1999) Med. Phys. , vol.26 , pp. 1925-1931
    • Wallace, R.E.1    Fan, J.J.2