메뉴 건너뛰기




Volumn 16, Issue 12, 2005, Pages 2466-2472

Geometric calibration of a coordinate measuring machine using a laser tracking system

Author keywords

Calibration; CMM (coordinate measuring machine); Laser tracking system; Parametric error

Indexed keywords

CALIBRATION; ERROR ANALYSIS; LASER PULSES; PLATES (STRUCTURAL COMPONENTS);

EID: 27844508571     PISSN: 09570233     EISSN: 13616501     Source Type: Journal    
DOI: 10.1088/0957-0233/16/12/010     Document Type: Article
Times cited : (107)

References (8)
  • 1
    • 27844566448 scopus 로고    scopus 로고
    • Calibration and uncertainty of CMM based on estimation of geometric errors
    • Umetsu K and Furutani R 2003 Calibration and uncertainty of CMM based on estimation of geometric errors JSPE 69 64
    • (2003) JSPE , vol.69 , pp. 64
    • Umetsu, K.1    Furutani, R.2
  • 2
    • 0000020381 scopus 로고
    • A uniform concept for calibration, acceptance test, and periodic inspection of coordinate measuring machines using reference objects
    • Kunzman H, Trapet E and Waldele F 1990 A uniform concept for calibration, acceptance test, and periodic inspection of coordinate measuring machines using reference objects Ann. CIRP 39 561
    • (1990) Ann. CIRP , vol.39 , pp. 561
    • Kunzman, H.1    Trapet, E.2    Waldele, F.3
  • 3
    • 0028747106 scopus 로고
    • Self-calibration method and software error correction for three-dimensional coordinate measuring machines using artifact measurements
    • Kruth J P, Vanherck P and De Jonge L 1994 Self-calibration method and software error correction for three-dimensional coordinate measuring machines using artifact measurements Measurement 14 157
    • (1994) Measurement , vol.14 , Issue.2 , pp. 157
    • Kruth, J.P.1    Vanherck, P.2    De Jonge, L.3
  • 4
    • 0036504698 scopus 로고    scopus 로고
    • High-performance laser tracker using an articulating mirror for the calibration of coordinate measuring machine
    • Jiang H, Osawa S, Takatsuji T, Noguchi H and Kurosawa T 2002 High-performance laser tracker using an articulating mirror for the calibration of coordinate measuring machine Opt. Eng. 41 632
    • (2002) Opt. Eng. , vol.41 , Issue.3 , pp. 632
    • Jiang, H.1    Osawa, S.2    Takatsuji, T.3    Noguchi, H.4    Kurosawa, T.5
  • 5
    • 0002635867 scopus 로고    scopus 로고
    • Whole-viewing-angle cat's-eye retroreflector as a target of laser trackers
    • Takatsuji T et al 1999 Whole-viewing-angle cat's-eye retroreflector as a target of laser trackers Meas. Sci. Technol. 10 N87-90
    • (1999) Meas. Sci. Technol. , vol.10 , Issue.7
    • Takatsuji, T.1    Al, E.2
  • 6
    • 0038417179 scopus 로고    scopus 로고
    • An improved cat's-eye retroreflector used in a laser tracking interferometer system
    • Lin Y, Zhang G and Li Z 2003 An improved cat's-eye retroreflector used in a laser tracking interferometer system Meas. Sci. Technol. 14 N36-40
    • (2003) Meas. Sci. Technol. , vol.14 , Issue.6
    • Lin, Y.1    Zhang, G.2    Li, Z.3
  • 7
    • 34250009147 scopus 로고
    • The refractive index of air
    • Edlen B 1966 The refractive index of air Metrologia 2 71
    • (1966) Metrologia , vol.2 , Issue.2 , pp. 71
    • Edlen, B.1
  • 8
    • 0033718729 scopus 로고    scopus 로고
    • The relationship between the measurement error and the arrangement of laser trackers in laser trilateration
    • Takatsuji T, Goto M, Kirita A, Kurosawa T and Tanimura Y 2000 The relationship between the measurement error and the arrangement of laser trackers in laser trilateration Meas. Sci. Technol. 11 477
    • (2000) Meas. Sci. Technol. , vol.11 , Issue.5 , pp. 477
    • Takatsuji, T.1    Goto, M.2    Kirita, A.3    Kurosawa, T.4    Tanimura, Y.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.