메뉴 건너뛰기




Volumn 85, Issue 2-3, 2006, Pages 196-204

Measurement of contaminant removal from skin using a portable fluorescence scanning system

Author keywords

Clearance; Dose assessment; Fluorescence scanning; Particles; Skin

Indexed keywords

CAMERAS; CHARGE COUPLED DEVICES; CONTAMINATION; FLUORESCENCE; LIGHT EMITTING DIODES; RADIOISOTOPES; SKIN;

EID: 27844444458     PISSN: 0265931X     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jenvrad.2004.07.008     Document Type: Conference Paper
Times cited : (13)

References (16)
  • 3
    • 0026962546 scopus 로고
    • Synthesis and characterisation of colloidal dispersions of fluorescent monodisperse silica spheres
    • A. van Blaaderen, and A. Vrij Synthesis and characterisation of colloidal dispersions of fluorescent monodisperse silica spheres Langmuir 8 1992 2921 2931
    • (1992) Langmuir , vol.8 , pp. 2921-2931
    • Van Blaaderen, A.1    Vrij, A.2
  • 5
    • 26544469741 scopus 로고    scopus 로고
    • Opto-thermal measurement of stratum corneum renewal time
    • J.A. Cowen, R.E. Imhof, and P. Xiao Opto-thermal measurement of stratum corneum renewal time Analytical Sciences 17 s4 2001 353 356
    • (2001) Analytical Sciences , vol.17 , Issue.S4 , pp. 353-356
    • Cowen, J.A.1    Imhof, R.E.2    Xiao, P.3
  • 10
    • 0000781706 scopus 로고
    • Ein beitrag zur optik der farbanstriche
    • P. Kubelka, and F. Munk Ein beitrag zur optik der farbanstriche Zeitschrift fr Technische Physik 11a 193 1931 593 601
    • (1931) Zeitschrift Fr Technische Physik , vol.11 , Issue.193 , pp. 593-601
    • Kubelka, P.1    Munk, F.2
  • 13
    • 0027470836 scopus 로고
    • Wind tunnel experiments on the resuspension of particulate material
    • K.W. Nicholson Wind tunnel experiments on the resuspension of particulate material Atmospheric Environment 27A 2 1993 181 188
    • (1993) Atmospheric Environment , vol.27 , Issue.2 , pp. 181-188
    • Nicholson, K.W.1
  • 15
    • 0028657543 scopus 로고
    • A novel lighting system for the measurement of dermal exposure using a fluorescent dye and an image processor
    • M.W. Roff A novel lighting system for the measurement of dermal exposure using a fluorescent dye and an image processor Annals of Occupational Hygiene 30 6 1994 903 919
    • (1994) Annals of Occupational Hygiene , vol.30 , Issue.6 , pp. 903-919
    • Roff, M.W.1
  • 16
    • 0019365978 scopus 로고
    • The lightpipe luminoscope for monitoring occupational skin contamination
    • T. Vo-Dinh, and R.B. Gammage The lightpipe luminoscope for monitoring occupational skin contamination American Industrial Hygiene Association Journal 42 2 1981 112 120
    • (1981) American Industrial Hygiene Association Journal , vol.42 , Issue.2 , pp. 112-120
    • Vo-Dinh, T.1    Gammage, R.B.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.