메뉴 건너뛰기




Volumn 31, Issue 11, 2005, Pages 1499-1508

Speckle classification for sensorless freehand 3-D ultrasound

Author keywords

Freehand three dimensional ultrasound; Speckle decorrelation; Speckle detection

Indexed keywords

DATA ACQUISITION; SENSORS; TISSUE; VOLUME MEASUREMENT;

EID: 27744579673     PISSN: 03015629     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ultrasmedbio.2005.07.007     Document Type: Article
Times cited : (25)

References (28)
  • 2
    • 0030836167 scopus 로고    scopus 로고
    • Determination of scan-plane motion using speckle decorrelation: Theoretical considerations and initial test
    • J.F. Chen, J.B. Fowlkes, P.L. Carson, J.M. Rubin Determination of scan-plane motion using speckle decorrelation Theoretical considerations and initial test Int J Imaging Syst Technol 8 1997 38 44
    • (1997) Int J Imaging Syst Technol , vol.8 , pp. 38-44
    • Chen, J.F.1    Fowlkes, J.B.2    Carson, P.L.3    Rubin, J.M.4
  • 3
    • 0026825970 scopus 로고
    • Modeling of ultrasound speckle with application in flaw detection in metals
    • F.S. Cohen Modeling of ultrasound speckle with application in flaw detection in metals IEEE Trans Ultrason Ferroelec Freq Control 40 3 1992 624 632
    • (1992) IEEE Trans Ultrason Ferroelec Freq Control , vol.40 , Issue.3 , pp. 624-632
    • Cohen, F.S.1
  • 5
    • 0020030635 scopus 로고
    • Measurement of soft tissue motion using correlation between A-scans
    • R.J. Dickinson, C.R. Hill Measurement of soft tissue motion using correlation between A-scans Ultrasound Med Biol 8 1982 263 271
    • (1982) Ultrasound Med Biol , vol.8 , pp. 263-271
    • Dickinson, R.J.1    Hill, C.R.2
  • 6
    • 0028618935 scopus 로고
    • Ultrasound echo envelope analysis using a homodyned k distribution signal model
    • V. Dutt, J.F. Greenleaf Ultrasound echo envelope analysis using a homodyned k distribution signal model Ultrason Imaging 16 1994 265 287
    • (1994) Ultrason Imaging , vol.16 , pp. 265-287
    • Dutt, V.1    Greenleaf, J.F.2
  • 7
    • 84965770587 scopus 로고
    • Speckle analysis using signal to noise ratios based on fractional order moments
    • V. Dutt, J.F. Greenleaf Speckle analysis using signal to noise ratios based on fractional order moments Ultrason Imaging 17 1995 251 268
    • (1995) Ultrason Imaging , vol.17 , pp. 251-268
    • Dutt, V.1    Greenleaf, J.F.2
  • 10
  • 13
    • 0035713311 scopus 로고    scopus 로고
    • Improved method for determining resolution zones in ultrasound phantoms with spherical simulated lesions
    • J.M. Kofler Jr, E.L. Madsen Improved method for determining resolution zones in ultrasound phantoms with spherical simulated lesions Ultrasound Med Biol 27 12 2001 1667 1676
    • (2001) Ultrasound Med Biol , vol.27 , Issue.12 , pp. 1667-1676
    • Kofler Jr., J.M.1    Madsen, E.L.2
  • 14
    • 27744539595 scopus 로고    scopus 로고
    • System and method for 3D medical imaging using 2D scan data. US patent 5,582,173. (Application number 529778), 1995.
    • Li M. System and method for 3D medical imaging using 2D scan data. US patent 5,582,173. (Application number 529778), 1995.
    • Li, M.1
  • 15
    • 0032076844 scopus 로고    scopus 로고
    • Liquid or solid ultrasonically tissue-mimicking materials with very low scatter
    • E.L. Madsen, G.R. Frank, F. Dong Liquid or solid ultrasonically tissue-mimicking materials with very low scatter Ultrasound Med Biol 24 4 1998 535 542
    • (1998) Ultrasound Med Biol , vol.24 , Issue.4 , pp. 535-542
    • Madsen, E.L.1    Frank, G.R.2    Dong, F.3
  • 17
    • 0032423607 scopus 로고    scopus 로고
    • Three-dimensional ultrasound imaging
    • T.R. Nelson, D.H. Pretorius Three-dimensional ultrasound imaging Ultrasound Med Biol 24 9 1998 1243 1270
    • (1998) Ultrasound Med Biol , vol.24 , Issue.9 , pp. 1243-1270
    • Nelson, T.R.1    Pretorius, D.H.2
  • 18
    • 0036557883 scopus 로고    scopus 로고
    • Analysis of speckle in ultrasound images using fractional-order statistics of the homodyned k-distribution
    • R.W. Prager, A.H. Gee, G.M. Treece, L.H. Berman Analysis of speckle in ultrasound images using fractional-order statistics of the homodyned k-distribution Ultrasonics 40 1-8 2002 133 137
    • (2002) Ultrasonics , vol.40 , Issue.1-8 , pp. 133-137
    • Prager, R.W.1    Gee, A.H.2    Treece, G.M.3    Berman, L.H.4
  • 19
    • 0036557891 scopus 로고    scopus 로고
    • Freehand 3D ultrasound without voxels: Volume measurement and visualisation using the Stradx system
    • R.W. Prager, A.H. Gee, G.M. Treece, L.H. Berman Freehand 3D ultrasound without voxels Volume measurement and visualisation using the Stradx system Ultrasonics 40 1-8 2002 109 115
    • (2002) Ultrasonics , vol.40 , Issue.1-8 , pp. 109-115
    • Prager, R.W.1    Gee, A.H.2    Treece, G.M.3    Berman, L.H.4
  • 20
    • 0037290194 scopus 로고    scopus 로고
    • Decompression and speckle detection for ultrasound images using a homodyned k distribution
    • R.W. Prager, A.H. Gee, G.M. Treece, L.H. Berman Decompression and speckle detection for ultrasound images using a homodyned k distribution Pattern Recognit Lett 24 4-5 2003 705 713
    • (2003) Pattern Recognit Lett , vol.24 , Issue.4-5 , pp. 705-713
    • Prager, R.W.1    Gee, A.H.2    Treece, G.M.3    Berman, L.H.4
  • 21
  • 23
    • 0036753986 scopus 로고    scopus 로고
    • Correction of probe pressure artifacts in freehand 3D ultrasound
    • G.M. Treece, R.W. Prager, A.H. Gee, L.H. Berman Correction of probe pressure artifacts in freehand 3D ultrasound Med Image Anal 6 3 2002 199 215
    • (2002) Med Image Anal , vol.6 , Issue.3 , pp. 199-215
    • Treece, G.M.1    Prager, R.W.2    Gee, A.H.3    Berman, L.H.4
  • 24
    • 0031728262 scopus 로고    scopus 로고
    • Automated three-dimensional US frame positioning computed from elevational speckle decorrelation
    • T.A. Tuthill, J.F. Krücker, J.B. Fowlkes, P.L. Carson Automated three-dimensional US frame positioning computed from elevational speckle decorrelation Radiology 209 1998 575 582
    • (1998) Radiology , vol.209 , pp. 575-582
    • Tuthill, T.A.1    Krücker, J.F.2    Fowlkes, J.B.3    Carson, P.L.4
  • 25
    • 0023332753 scopus 로고
    • Statistical properties of radio-frequency and envelope-detected signals with applications to medical ultrasound
    • R.F. Wagner, M.F. Insana, D.G. Brown Statistical properties of radio-frequency and envelope-detected signals with applications to medical ultrasound J Opt Soc Am A 4 5 1987 910 922
    • (1987) J Opt Soc Am a , vol.4 , Issue.5 , pp. 910-922
    • Wagner, R.F.1    Insana, M.F.2    Brown, D.G.3
  • 28
    • 0019620778 scopus 로고
    • Speckle in ultrasonic imaging
    • P.N.T. Wells, M. Halliwell Speckle in ultrasonic imaging Ultrasonics 195 1981 225 229
    • (1981) Ultrasonics , vol.195 , pp. 225-229
    • Wells, P.N.T.1    Halliwell, M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.