메뉴 건너뛰기




Volumn 75-79, Issue SUPPL., 2005, Pages 193-200

The European development of a full scale switching unit for the ITER switching and discharging networks

Author keywords

DC circuit breakers; ITER; Superconductive magnet protection

Indexed keywords

MAGNETIC FIELD EFFECTS; SWITCHING;

EID: 27744573155     PISSN: 09203796     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.fusengdes.2005.06.225     Document Type: Article
Times cited : (52)

References (10)
  • 1
    • 27744458260 scopus 로고    scopus 로고
    • ITER design description document
    • DDD 4.1
    • ITER Design Description Document, DDD 4.1, Pulsed Power Supplies, 2001.
    • (2001) Pulsed Power Supplies
  • 3
    • 27744478467 scopus 로고    scopus 로고
    • ITER design description document
    • DDD 1.1
    • ITER Design Description Document, DDD 1.1, Magnet Engineering, 2001.
    • (2001) Magnet Engineering
  • 5
    • 0031625766 scopus 로고    scopus 로고
    • Design, construction and operation of the 66 kA life test facility for the ITER magnet protection vacuum circuit breakers
    • San Diego, CA
    • F. Bellina Design, construction and operation of the 66 kA life test facility for the ITER magnet protection vacuum circuit breakers Proceedings of the 17th IEEE/NPSS Symposium on Fusion Engineering San Diego, CA 1997 1137 1140
    • (1997) Proceedings of the 17th IEEE/NPSS Symposium on Fusion Engineering , pp. 1137-1140
    • Bellina, F.1
  • 6
    • 0031619652 scopus 로고    scopus 로고
    • The development and testing of a 66 kA by-pass switch with arc commutation capability for the ITER coils power supply system
    • San Diego, CA
    • T. Bonicelli The development and testing of a 66 kA by-pass switch with arc commutation capability for the ITER coils power supply system Proceedings of the 17th IEEE/NPSS Symposium on Fusion Engineering San Diego, CA 1997 1129 1132
    • (1997) Proceedings of the 17th IEEE/NPSS Symposium on Fusion Engineering , pp. 1129-1132
    • Bonicelli, T.1
  • 9
    • 0026140132 scopus 로고
    • Life tests on vacuum switches breaking 50 kA unidirectional current
    • I. Benfatto Life tests on vacuum switches breaking 50 kA unidirectional current IEEE Trans. Power Deliv. 6 2 1991 824 832
    • (1991) IEEE Trans. Power Deliv. , vol.6 , Issue.2 , pp. 824-832
    • Benfatto, I.1
  • 10
    • 0031634824 scopus 로고    scopus 로고
    • Parametric analysis of current extinction in counter-pulse system
    • P. Bettini, A. De Lorenzi, and A. Maschio Parametric analysis of current extinction in counter-pulse system Plasma Dev. Operat. 5 4 1998
    • (1998) Plasma Dev. Operat. , vol.5 , Issue.4
    • Bettini, P.1    De Lorenzi, A.2    Maschio, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.