메뉴 건너뛰기




Volumn 115, Issue 1-2, 2005, Pages 45-50

The axial distribution of holdups in an industrial-scale bubble column with evaluated pressure using γ-ray attenuation approach

Author keywords

Ray attenuation; Axial distribution; Gas liquid column; Holdup

Indexed keywords

ATTENUATION; DATA PROCESSING; DENSITOMETERS; GAMMA RAYS; SURFACE TENSION; TWO PHASE FLOW; VISCOSITY;

EID: 27744566677     PISSN: 13858947     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.cej.2005.09.003     Document Type: Article
Times cited : (23)

References (19)
  • 3
    • 0003046162 scopus 로고    scopus 로고
    • Reaction engineering of emerging oxidation process
    • P.L. Mill, and R.V. Chandhari Reaction engineering of emerging oxidation process Catal. Today 48 1999 17 29
    • (1999) Catal. Today , vol.48 , pp. 17-29
    • Mill, P.L.1    Chandhari, R.V.2
  • 4
    • 0026878434 scopus 로고
    • Catalytic liquid-phase oxidation of refractory organics in waste water
    • A. Pintar, and J. Levec Catalytic liquid-phase oxidation of refractory organics in waste water Chem. Eng. Sci. 47 1992 2395 2400
    • (1992) Chem. Eng. Sci. , vol.47 , pp. 2395-2400
    • Pintar, A.1    Levec, J.2
  • 5
    • 0035147728 scopus 로고    scopus 로고
    • Gamma ray tomography design for the measurement of holdup profiles in two-phase bubble columns
    • U.P. Veera Gamma ray tomography design for the measurement of holdup profiles in two-phase bubble columns Chem. Eng. J. 81 2001 251 260
    • (2001) Chem. Eng. J. , vol.81 , pp. 251-260
    • Veera, U.P.1
  • 6
    • 10044246706 scopus 로고
    • The mass-transfer efficiency of distillation and gas absorption plate columns
    • P.H. Calderbank, F. Evans, and J. Rennie The mass-transfer efficiency of distillation and gas absorption plate columns Inst. Chem. Eng., London 125 1961 51 58
    • (1961) Inst. Chem. Eng., London , vol.125 , pp. 51-58
    • Calderbank, P.H.1    Evans, F.2    Rennie, J.3
  • 7
    • 0019634753 scopus 로고
    • Design aspects of gamma densitometers for void fraction measurements in small scale two-phase flows
    • A.M.C. Chan, and S. Banerjee Design aspects of gamma densitometers for void fraction measurements in small scale two-phase flows Nucl. Instrum. Method 190 1981 135 148
    • (1981) Nucl. Instrum. Method , vol.190 , pp. 135-148
    • Chan, A.M.C.1    Banerjee, S.2
  • 8
    • 0028497721 scopus 로고
    • Optimization of a one-shot gamma densitometer to measuring area-averaged void-fractions of gas-liquid flows in narrow pipe
    • C.S. Eberle, W.H. Leung, M. Ishi, and S.T. Kevanker Optimization of a one-shot gamma densitometer to measuring area-averaged void-fractions of gas-liquid flows in narrow pipe Meas. Sci. Technol. 5 1994 1146 1158
    • (1994) Meas. Sci. Technol. , vol.5 , pp. 1146-1158
    • Eberle, C.S.1    Leung, W.H.2    Ishi, M.3    Kevanker, S.T.4
  • 9
    • 0030616237 scopus 로고    scopus 로고
    • Gamma-densitometry tomography of gas holdup spatial distribution in industrial scale bubble columns
    • K.A. Schollenberger, J.R. Torczynski, D.R. Adkins, T.J. O'Hern, and N.B. Jackson Gamma-densitometry tomography of gas holdup spatial distribution in industrial scale bubble columns Chem. Eng. Sci. 52 1997 2037 2048
    • (1997) Chem. Eng. Sci. , vol.52 , pp. 2037-2048
    • Schollenberger, K.A.1    Torczynski, J.R.2    Adkins, D.R.3    O'Hern, T.J.4    Jackson, N.B.5
  • 10
    • 0034090184 scopus 로고    scopus 로고
    • Measurement of gas holdup profiles in bubble column by gamma ray tomography: Effect of liquid phase properties
    • V.P. Veera, and J.B. Joshi Measurement of gas holdup profiles in bubble column by gamma ray tomography: effect of liquid phase properties Trans. I. Chem. Eng. 78 2000 425 434 (Part A)
    • (2000) Trans. I. Chem. Eng. , vol.78 , pp. 425-434
    • Veera, V.P.1    Joshi, J.B.2
  • 11
    • 0033150848 scopus 로고    scopus 로고
    • Measurement of gas holdup profiles in bubble column by gamma ray tomography: Effect of sparger design and height of dispersion in bubble column
    • V.P. Veera, and J.B. Joshi Measurement of gas holdup profiles in bubble column by gamma ray tomography: effect of sparger design and height of dispersion in bubble column Trans. I. Chem. Eng. 77 1999 303 317 (Part A)
    • (1999) Trans. I. Chem. Eng. , vol.77 , pp. 303-317
    • Veera, V.P.1    Joshi, J.B.2
  • 12
    • 0035893305 scopus 로고    scopus 로고
    • Gas holdup profiles in foaming liquid in bubble column
    • V.P. Veera, K.L. Kataria, and J.B. Joshi Gas holdup profiles in foaming liquid in bubble column Chem. Eng. J. 84 2001 247 256
    • (2001) Chem. Eng. J. , vol.84 , pp. 247-256
    • Veera, V.P.1    Kataria, K.L.2    Joshi, J.B.3
  • 13
    • 0029672304 scopus 로고    scopus 로고
    • Application of γ-ray attenuation for measurement of gas holdups and flow regime transition in bubble columns
    • D.B. Bukur, J.G. Daly, and S.A. Patel Application of γ-ray attenuation for measurement of gas holdups and flow regime transition in bubble columns Ind. Eng. Chem. Res. 35 1996 70 80
    • (1996) Ind. Eng. Chem. Res. , vol.35 , pp. 70-80
    • Bukur, D.B.1    Daly, J.G.2    Patel, S.A.3
  • 14
    • 0037392866 scopus 로고    scopus 로고
    • Flow regimes and gas holdup in paper pulp-water-gas three-phase slurry flow
    • T. Xie, S.M. Ghiaasiaan, S. Karrila, and T. Mcdonough Flow regimes and gas holdup in paper pulp-water-gas three-phase slurry flow Chem. Eng. Sci. 58 2003 1417 1430
    • (2003) Chem. Eng. Sci. , vol.58 , pp. 1417-1430
    • Xie, T.1    Ghiaasiaan, S.M.2    Karrila, S.3    McDonough, T.4
  • 15
    • 0035034387 scopus 로고    scopus 로고
    • Gas holdup in bubble column at elevated pressure via computed tomography
    • A. Kemoun, B.C. Ong, P. Gupta, and H.A. Muthanna Gas holdup in bubble column at elevated pressure via computed tomography Int. J. Multiphase Flow 27 2001 929 946
    • (2001) Int. J. Multiphase Flow , vol.27 , pp. 929-946
    • Kemoun, A.1    Ong, B.C.2    Gupta, P.3    Muthanna, H.A.4
  • 17
    • 0028992670 scopus 로고
    • A gamma ray tomographic scanner for imaging voidage distribution in two phase flow systems
    • S.B. Kumar, D. Moslemian, and M.P. Dudukovic A gamma ray tomographic scanner for imaging voidage distribution in two phase flow systems Flow Meas. Instrum. 6 1995 61 73
    • (1995) Flow Meas. Instrum. , vol.6 , pp. 61-73
    • Kumar, S.B.1    Moslemian, D.2    Dudukovic, M.P.3
  • 18
    • 0023560295 scopus 로고
    • Gas holdup in a bubble column for Fischer-Tropsch synthesis
    • D.B. Bukur, and J.G. Daly Gas holdup in a bubble column for Fischer-Tropsch synthesis Chem. Eng. Sci. 42 1987 2967 2969
    • (1987) Chem. Eng. Sci. , vol.42 , pp. 2967-2969
    • Bukur, D.B.1    Daly, J.G.2
  • 19
    • 0025227738 scopus 로고
    • Bubble size distribution in Fischer-Tropsch derived wases in a bubble column
    • S.A. Patel, J.G. Daly, and D.B. Bukur Bubble size distribution in Fischer-Tropsch derived wases in a bubble column AIChE J. 36 1990 93 105
    • (1990) AIChE J. , vol.36 , pp. 93-105
    • Patel, S.A.1    Daly, J.G.2    Bukur, D.B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.