-
1
-
-
0345633594
-
3D reconstruction of high contrast objects using C-arm image intensifier projection data
-
M. Grass, R. Koppe, E. Klotz, R. Proksa, M.H. Kuhn, and H. Aerts 3D reconstruction of high contrast objects using C-arm image intensifier projection data Comput Med Imaging Graphics 23 6 1999 311 321
-
(1999)
Comput Med Imaging Graphics
, vol.23
, Issue.6
, pp. 311-321
-
-
Grass, M.1
Koppe, R.2
Klotz, E.3
Proksa, R.4
Kuhn, M.H.5
Aerts, H.6
-
2
-
-
0009472813
-
3D reconstruction and imaging based on C-arm systems
-
M. Grass, R. Koppe, E. Klotz, J. Op de Beek, and R. Kemkers 3D reconstruction and imaging based on C-arm systems Med Biol Eng Comput 37 2 1999 1520 1521
-
(1999)
Med Biol Eng Comput
, vol.37
, Issue.2
, pp. 1520-1521
-
-
Grass, M.1
Koppe, R.2
Klotz, E.3
Op De Beek, J.4
Kemkers, R.5
-
3
-
-
27744471304
-
-
Hermes Science Publications Paris
-
M. Grass, R. Guillemaud, R. Koppe, E. Klotz, V. Rasche, and J. Op de Beek La radiologie tridimensionelle, La tomographie medicale-Imagerie morphologique et imagerie fonctionelle 2002 Hermes Science Publications Paris
-
(2002)
La Radiologie Tridimensionelle, la Tomographie Medicale-Imagerie Morphologique et Imagerie Fonctionelle
-
-
Grass, M.1
Guillemaud, R.2
Koppe, R.3
Klotz, E.4
Rasche, V.5
Op De Beek, J.6
-
4
-
-
10044281022
-
Performance of image intensifier-equipped X-ray systems for three-dimensional imaging
-
London, UK: Elsevier;
-
Rasche V, Schreiber B, Graeff C, Istel T, Schomberg H, Grass M, et al. Performance of image intensifier-equipped X-ray systems for three-dimensional imaging. In: CARS 2003-computer assisted radiology and surgery: proceedings of the 17th international congress and exhibition. London, UK: Elsevier; 2003. p. 187-92.
-
(2003)
CARS 2003-computer Assisted Radiology and Surgery: Proceedings of the 17th International Congress and Exhibition
, pp. 187-192
-
-
Rasche, V.1
Schreiber, B.2
Graeff, C.3
Istel, T.4
Schomberg, H.5
Grass, M.6
-
5
-
-
0033057536
-
Comparison of methods for instantaneous angiographic blood flow measurement
-
S.D. Shpilfoygel, R. Jahan, R.A. Close, G.R. Duckwiler, and D.J. Valentino Comparison of methods for instantaneous angiographic blood flow measurement Med Phys 26 6 1999 862 871
-
(1999)
Med Phys
, vol.26
, Issue.6
, pp. 862-871
-
-
Shpilfoygel, S.D.1
Jahan, R.2
Close, R.A.3
Duckwiler, G.R.4
Valentino, D.J.5
-
6
-
-
0033805467
-
X-ray videodensitometric methods for blood flow and velocity measurement: A critical review of literature
-
S.D. Shpilfoygel, R.A. Close, D.J. Valentino, and G.R. Duckwiler X-ray videodensitometric methods for blood flow and velocity measurement: a critical review of literature Med Phys 27 9 2000 2008 2023
-
(2000)
Med Phys
, vol.27
, Issue.9
, pp. 2008-2023
-
-
Shpilfoygel, S.D.1
Close, R.A.2
Valentino, D.J.3
Duckwiler, G.R.4
-
7
-
-
84875568139
-
Real-time tracking of contrast bolus propagation in X-ray peripheral angiography
-
Santa Barbara, CA, USA;
-
Wu Z, Qian J.-Z. Real-time tracking of contrast bolus propagation in X-ray peripheral angiography. In: Proceedings of the IEEE workshop on biomedical image analysis. Santa Barbara, CA, USA; 1998. p. 164-71.
-
(1998)
Proceedings of the IEEE Workshop on Biomedical Image Analysis
, pp. 164-171
-
-
Wu, Z.1
Qian, J.-Z.2
-
8
-
-
0033682807
-
Validation of an optical flow algorithm to measure blood flow waveforms in arteries using dynamic digital X-ray images
-
San Diego, CA, USA;
-
Rhode K, Lambrou T, Hawkes DJ, Hamilton G, Seifalian AM. Validation of an optical flow algorithm to measure blood flow waveforms in arteries using dynamic digital X-ray images. In: proceedings of the SPIE medical imaging conference. San Diego, CA, USA; 2000. p. 1414-25.
-
(2000)
Proceedings of the SPIE Medical Imaging Conference
, pp. 1414-1425
-
-
Rhode, K.1
Lambrou, T.2
Hawkes, D.J.3
Hamilton, G.4
Seifalian, A.M.5
-
9
-
-
0036489383
-
An Xray-based method for the determination of the contrast agent propagation in 3-D vessel structures
-
H. Schmitt, M. Grass, V. Rasche, O. Schramm, S. Hähnel, and K. Sartor An Xray-based method for the determination of the contrast agent propagation in 3-D vessel structures IEEE Trans Med Imag 23 3 2002 251 262
-
(2002)
IEEE Trans Med Imag
, vol.23
, Issue.3
, pp. 251-262
-
-
Schmitt, H.1
Grass, M.2
Rasche, V.3
Schramm, O.4
Hähnel, S.5
Sartor, K.6
-
11
-
-
0028936347
-
Portal vein reconstruction based on topology
-
C. Zahlten, H. Jürgens, C.J. Evertsz, R. Leppek, H.O. Peitgen, and K.J. Klose Portal vein reconstruction based on topology Eur J Radiol 19 2 1995 96 100
-
(1995)
Eur J Radiol
, vol.19
, Issue.2
, pp. 96-100
-
-
Zahlten, C.1
Jürgens, H.2
Evertsz, C.J.3
Leppek, R.4
Peitgen, H.O.5
Klose, K.J.6
-
12
-
-
0035079378
-
Reduction of patient motion artifacts in digital subtraction angiography: Evaluation of a fast and fully automatic technique
-
E.H.W. Meijering, W.J. Niessen, J.B.A.J. van der Molen, G.A.P. de Kort, R.T.H. Lo, and W.P.T.M. Mali Reduction of patient motion artifacts in digital subtraction angiography: evaluation of a fast and fully automatic technique Radiology 219 2001 288 293
-
(2001)
Radiology
, vol.219
, pp. 288-293
-
-
Meijering, E.H.W.1
Niessen, W.J.2
Van Der Molen, J.B.A.J.3
De Kort, G.A.P.4
Lo, R.T.H.5
Mali, W.P.T.M.6
-
13
-
-
0347479219
-
Image stacking in X-ray angiography using entropy values - Initial experience
-
H. Schmitt, M. Grass, S. Heiland, S. Hähnel, and K. Sartor Image stacking in X-ray angiography using entropy values - initial experience Radiology 230 1 2004 294 298
-
(2004)
Radiology
, vol.230
, Issue.1
, pp. 294-298
-
-
Schmitt, H.1
Grass, M.2
Heiland, S.3
Hähnel, S.4
Sartor, K.5
-
14
-
-
27744494754
-
Bestimmung von retinalem Blutfluss und arterieller Blutgeschwindigkeit durch Videosequenzanalyse von Fluoreszenzangiographien
-
Springer: Munich, Germany;
-
Bräuer C, Vilser W. Bestimmung von retinalem Blutfluss und arterieller Blutgeschwindigkeit durch Videosequenzanalyse von Fluoreszenzangiographien. In: bildverarbeitung für die Medizin, Springer: Munich, Germany; 2000. p. 272-6.
-
(2000)
Bildverarbeitung für Die Medizin
, pp. 272-276
-
-
Bräuer, C.1
Vilser, W.2
-
15
-
-
0032231768
-
Evaluation of intraaneurysmal blood velcoity by time-density curve analysis and digital subtraction angiography
-
H. Tenjin, F. Asakura, Y. Nakahara, K. Matsumoto, T. Matsuo, and F. Urano Evaluation of intraaneurysmal blood velcoity by time-density curve analysis and digital subtraction angiography Am J Neuroradiol 19 2 1998 1303 1307
-
(1998)
Am J Neuroradiol
, vol.19
, Issue.2
, pp. 1303-1307
-
-
Tenjin, H.1
Asakura, F.2
Nakahara, Y.3
Matsumoto, K.4
Matsuo, T.5
Urano, F.6
-
19
-
-
0347881489
-
The "kissing vessel"-artifact: A problem occurring in the visualization of intracranial aneurysms using volume rendering and virtual endoscopy
-
B. Tomandl, P. Hastreiter, K. Eberhardt, C. Rezk-Salama, C. Nimsky, and M. Buchfelde The "kissing vessel"-artifact: a problem occurring in the visualization of intracranial aneurysms using volume rendering and virtual endoscopy Radiology 213 P 1999 311
-
(1999)
Radiology
, vol.213
, Issue.P
, pp. 311
-
-
Tomandl, B.1
Hastreiter, P.2
Eberhardt, K.3
Rezk-Salama, C.4
Nimsky, C.5
Buchfelde, M.6
-
20
-
-
0042739012
-
Estimation of bolus dispersion effects in perfusion MRI using image-based computational fluid dynamics
-
F. Calamante, P.J. Yim, and J.R. Cebral Estimation of bolus dispersion effects in perfusion MRI using image-based computational fluid dynamics Neuroimage 19 2 2003 341 353
-
(2003)
Neuroimage
, vol.19
, Issue.2
, pp. 341-353
-
-
Calamante, F.1
Yim, P.J.2
Cebral, J.R.3
-
21
-
-
0038275868
-
Hemodynamic analysis of an adult vein of Galen aneurysm malformation by use of 3D image-based computational fluid dynamics
-
T. Hassan, E.V. Timofeev, M. Ezura, T. Saito, A. Takahashi, and K. Takayama Hemodynamic analysis of an adult vein of Galen aneurysm malformation by use of 3D image-based computational fluid dynamics Am J Neuroradiol 24 2003 1075 1082
-
(2003)
Am J Neuroradiol
, vol.24
, pp. 1075-1082
-
-
Hassan, T.1
Timofeev, E.V.2
Ezura, M.3
Saito, T.4
Takahashi, A.5
Takayama, K.6
|