메뉴 건너뛰기




Volumn 20, Issue 5, 2005, Pages 422-426

A case of intravascular ultrasound catheter entrapment after radius stent implantation

Author keywords

Entrapment; Intravascular ultrasound; Stent

Indexed keywords

AGED; ANGINA PECTORIS; ARTICLE; BALLOON EMBOLIZATION; CASE REPORT; CATHETERIZATION; DISEASE ASSOCIATION; FEMALE; FOLLOW UP; HEART CATHETER; HUMAN; INTRAVASCULAR ULTRASOUND; RESTENOSIS; STENT; THORAX PAIN;

EID: 27744522971     PISSN: 09148922     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (2)

References (9)
  • 1
    • 0034255377 scopus 로고    scopus 로고
    • Final results of the can routine ultrasound influence stent expansion (CRUISE) study
    • Fitzgerald PJ, et al: Final results of the can routine ultrasound influence stent expansion (CRUISE) study. Circulation 102: 523-530, 2000.
    • (2000) Circulation , vol.102 , pp. 523-530
    • Fitzgerald, P.J.1
  • 2
    • 0035908974 scopus 로고    scopus 로고
    • Randomized comparison of coronary stent implantation under ultrasound or angiographic guidance to reduce stent restenosis (OPTICUS Study)
    • Mudra H, et al: Randomized comparison of coronary stent implantation under ultrasound or angiographic guidance to reduce stent restenosis (OPTICUS Study). Circulation 104: 1343-1349, 2001.
    • (2001) Circulation , vol.104 , pp. 1343-1349
    • Mudra, H.1
  • 3
    • 0028893411 scopus 로고
    • The safety of intracoronary ultrasound: A multicenter survey of 2207 examinations
    • Hausmann D, et al: The safety of intracoronary ultrasound: A multicenter survey of 2207 examinations. Circulation 91: 623-630, 1995.
    • (1995) Circulation , vol.91 , pp. 623-630
    • Hausmann, D.1
  • 4
    • 0031055074 scopus 로고    scopus 로고
    • Is intravascular ultrasound after coronary stenting a safe procedure? Three cases of stent damage attributable to ICUS in a tantalum coil stent
    • Nicosia A, et al: Is intravascular ultrasound after coronary stenting a safe procedure? Three cases of stent damage attributable to ICUS in a tantalum coil stent. Cathet Cardiovasc Diagn 40: 265-270, 1997.
    • (1997) Cathet Cardiovasc Diagn , vol.40 , pp. 265-270
    • Nicosia, A.1
  • 5
    • 0036791789 scopus 로고    scopus 로고
    • Intravascular ultrasound catheter entrapment after coronary artery stenting
    • Sasseen BM, et al: Intravascular ultrasound catheter entrapment after coronary artery stenting. Cathet Cardiovasc Intervent 57: 229-233, 2002.
    • (2002) Cathet Cardiovasc Intervent , vol.57 , pp. 229-233
    • Sasseen, B.M.1
  • 6
    • 6744248634 scopus 로고    scopus 로고
    • The ESSEX (European Scimed Stent Experience) study
    • Kay IP, et al: The ESSEX (European Scimed Stent Experience) study. Cathet Cardiovasc Intervent 50: 419-425, 2000.
    • (2000) Cathet Cardiovasc Intervent , vol.50 , pp. 419-425
    • Kay, I.P.1
  • 7
    • 0035421786 scopus 로고    scopus 로고
    • Comparison of self-expanding and balloon-expandable stents for the reduction of restenosis
    • Han RO, et al: Comparison of self-expanding and balloon-expandable stents for the reduction of restenosis. Am J Cardiol 88: 253-259, 2001.
    • (2001) Am J Cardiol , vol.88 , pp. 253-259
    • Han, R.O.1
  • 8
    • 27744562923 scopus 로고    scopus 로고
    • Influence of balloon pressure after Raidus stent deployment on long-term angiographic outcome
    • Kataoka K, et al: Influence of balloon pressure after Raidus stent deployment on long-term angiographic outcome. Cir J 68(suppl 1): 595, 2004.
    • (2004) Cir J , vol.68 , Issue.SUPPL. 1 , pp. 595
    • Kataoka, K.1
  • 9
    • 27744584412 scopus 로고    scopus 로고
    • Japanese source


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.