메뉴 건너뛰기




Volumn 113, Issue 9, 2005, Pages 541-544

InDuo®, a novel combined insulin injection and blood glucose monitoring device - Effective and save as other devices, and patient preference

Author keywords

Blood glucose monitoring devices; Diabetes; InDuo ; Patient preference

Indexed keywords

FRUCTOSAMINE; GLUCOSE; HEMOGLOBIN A1C; HUMINSULIN BASAL; INSULIN; INSULIN ASPART; INSULIN LISPRO; ISOPHANE INSULIN; RECOMBINANT HUMAN INSULIN; UNCLASSIFIED DRUG;

EID: 27744515459     PISSN: 09477349     EISSN: None     Source Type: Journal    
DOI: 10.1055/s-2005-865928     Document Type: Article
Times cited : (2)

References (13)
  • 1
    • 0028158543 scopus 로고
    • Self-monitoring of blood glucose
    • American Diabètes Association. Self-monitoring of blood glucose. Diabetes Care 1994; 17: 81-86
    • (1994) Diabetes Care , vol.17 , pp. 81-86
  • 2
    • 0022521715 scopus 로고
    • Patient perspective on factors contributing to nonadherence to diabetes regimen
    • Ary DV, Toobert D, Wilson W, Glasgow RE. Patient perspective on factors contributing to nonadherence to diabetes regimen. Diabetes Care 1986; 9: 168-172
    • (1986) Diabetes Care , vol.9 , pp. 168-172
    • Ary, D.V.1    Toobert, D.2    Wilson, W.3    Glasgow, R.E.4
  • 4
    • 0008912229 scopus 로고    scopus 로고
    • An open prospective randomized trial to reduce the pain of blood glucose testing: Ear versus thumb
    • Carley SD et al. An open prospective randomized trial to reduce the pain of blood glucose testing: ear versus thumb. BMJ 2000; 321: 7252
    • (2000) BMJ , vol.321 , pp. 7252
    • Carley, S.D.1
  • 5
    • 0034605788 scopus 로고    scopus 로고
    • Earlobes are less convenient than fingerpricks for blood glucose testing
    • Cohen M. Earlobes are less convenient than fingerpricks for blood glucose testing. BMJ 2000; 321: 1161
    • (2000) BMJ , vol.321 , pp. 1161
    • Cohen, M.1
  • 6
    • 0033542663 scopus 로고    scopus 로고
    • Frequency of blood glucose monitoring in relation to glycaemic control: Observational study with diabetes database
    • Evans JM, Newton RW, Ruta DA, MacDonald TM, Stevenson RJ, Morris AD. Frequency of blood glucose monitoring in relation to glycaemic control: observational study with diabetes database. BMJ 1999; 319: 83-86
    • (1999) BMJ , vol.319 , pp. 83-86
    • Evans, J.M.1    Newton, R.W.2    Ruta, D.A.3    MacDonald, T.M.4    Stevenson, R.J.5    Morris, A.D.6
  • 7
    • 9144269668 scopus 로고    scopus 로고
    • Self-monitoring of blood glucose significantly improves metabolic control in patients with type 2 diabetes mellitus: The auto-surveillance intervention active (ASIA) study
    • Guerci B, Drouin P, Grange V, Bougneres P, Fontaine P, Kerlan V, Passa P, Thivolet Ch, Vialettes B, Charbonnel B, ASIA Group. Self-monitoring of blood glucose significantly improves metabolic control in patients with type 2 diabetes mellitus: the Auto-Surveillance Intervention Active (ASIA) study. Diabetes Metab 2003; 29: 587-594
    • (2003) Diabetes Metab , vol.29 , pp. 587-594
    • Guerci, B.1    Drouin, P.2    Grange, V.3    Bougneres, P.4    Fontaine, P.5    Kerlan, V.6    Passa, P.7    Thivolet, C.8    Vialettes, B.9    Charbonnel, B.10
  • 8
    • 0027234313 scopus 로고
    • Self-monitoring of blood glucose by adults with diabetes in the United States population
    • Harris MI et al. Self-monitoring of blood glucose by adults with diabetes in the United States population. Diabetes Care 1993; 16: 1116-1123
    • (1993) Diabetes Care , vol.16 , pp. 1116-1123
    • Harris, M.I.1
  • 9
    • 0033546899 scopus 로고    scopus 로고
    • Assessment of the pain of blood sugar testing: A randomized controlled trial
    • Loveland ME et al. Assessment of the pain of blood sugar testing: a randomized controlled trial. Lancet 1999; 354: 921-922
    • (1999) Lancet , vol.354 , pp. 921-922
    • Loveland, M.E.1
  • 11
    • 16344382163 scopus 로고    scopus 로고
    • Self-monitoring of blood glucose as part of a multi-component therapy among non-insulin requiring type 2 diabetes patients: A meta-analysis (1966-2004)
    • Sarol JN Jr, Nicodemus NA Jr, Tan KM, Grava MB. Self-monitoring of blood glucose as part of a multi-component therapy among non-insulin requiring type 2 diabetes patients: a meta-analysis (1966-2004). Curr Med Res Opin 2005; 21: 173-184
    • (2005) Curr Med Res Opin , vol.21 , pp. 173-184
    • Sarol Jr., J.N.1    Nicodemus Jr., N.A.2    Tan, K.M.3    Grava, M.B.4
  • 12
    • 1642294648 scopus 로고    scopus 로고
    • Effects of health maintenance organization coverage of self-monitoring devices on diabetes self-care and glycemic control
    • Soumerai SB, Mah C, Zhang F, Adams A, Barton M, Fajtova V, Ross-Degnan D. Effects of health maintenance organization coverage of self-monitoring devices on diabetes self-care and glycemic control. Arch Intern Med 2004; 164: 645-652
    • (2004) Arch Intern Med , vol.164 , pp. 645-652
    • Soumerai, S.B.1    Mah, C.2    Zhang, F.3    Adams, A.4    Barton, M.5    Fajtova, V.6    Ross-Degnan, D.7
  • 13
    • 0038813665 scopus 로고    scopus 로고
    • Alternative site blood glucose testing: Do patients prefer it
    • Tiezen KL, New JP. Alternative site blood glucose testing: do patients prefer it. Diabetic Medicine 2003; 20: 325-328
    • (2003) Diabetic Medicine , vol.20 , pp. 325-328
    • Tiezen, K.L.1    New, J.P.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.