Volumn 17, Issue 9, 2005, Pages 469-472

Electrophysiology: A novel radiation protection drape reduces radiation exposure during fluroscopy-guided electrophysiology procedures

Author keywords

Dose reduction; Drape; Electrophysiology; Fluoroscopy; Radiation

Indexed keywords

ADULT; AGED; ARTICLE; ARTIFICIAL HEART PACEMAKER; CARDIOVERSION; CATHETER ABLATION; CLINICAL ARTICLE; CONTROLLED STUDY; DEFIBRILLATOR; DOSIMETRY; ELBOW; EVALUATION; FEMALE; FEMORAL VEIN; FLUOROSCOPY; HAND; HEART ELECTROPHYSIOLOGY; HEART FUNCTION TEST; HUMAN; LABORATORY PERSONNEL; MALE; RADIATION DOSE; RADIATION EXPOSURE; RADIATION PROTECTION; RADIATION SCATTERING; COMPARATIVE STUDY; EQUIPMENT DESIGN; INSTRUMENTATION; METHODOLOGY; MIDDLE AGED; RADIATION INJURY; RADIOMETRY;

EID: 27744515218     PISSN: 10423931     EISSN: 15572501     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (31)

References (13)
  • 1
    • 0036224440 scopus 로고    scopus 로고
    • X-ray dose and associated risks from radiofrequency catheter ablation procedures
    • McFadden SL, Mooney RB, Shepherd PH. X-ray dose and associated risks from radiofrequency catheter ablation procedures. Br J Radiol 2002;75:253-265.
    • (2002) Br J Radiol , vol.75 , pp. 253-265
    • McFadden, S.L.1    Mooney, R.B.2    Shepherd, P.H.3
  • 2
    • 0033635562 scopus 로고    scopus 로고
    • Reduction of radiation exposure in the cardiac electrophysiology laboratory
    • Wittkampf FHM, Wever EFD, Vos K, et al. Reduction of radiation exposure in the cardiac electrophysiology laboratory. Pacing Clin Electrophysiol 2000;23:1638-1644.
    • (2000) Pacing Clin Electrophysiol , vol.23 , pp. 1638-1644
    • Wittkampf, F.H.M.1    Wever, E.F.D.2    Vos, K.3
  • 4
    • 0032520325 scopus 로고    scopus 로고
    • Radiation safety in the practice of cardiology
    • ACC expert consensus document. American College of Cardiology
    • ACC expert consensus document. Radiation safety in the practice of cardiology. American College of Cardiology. J Am Coll Cardiol 1998;31:892-913.
    • (1998) J Am Coll Cardiol , vol.31 , pp. 892-913
  • 5
    • 0027426839 scopus 로고
    • Radiation hazards to the cardiologist. A report of a subcommittee of the British Cardiac Society
    • Radiation hazards to the cardiologist. A report of a subcommittee of the British Cardiac Society. Br Heart J 1993;70:489-496.
    • (1993) Br Heart J , vol.70 , pp. 489-496
  • 6
    • 0035403070 scopus 로고    scopus 로고
    • Fluoroscopy: Patient radiation exposure issues
    • Mahesh M. Fluoroscopy: Patient radiation exposure issues. Radiographics 2001;21:1033-1045.
    • (2001) Radiographics , vol.21 , pp. 1033-1045
    • Mahesh, M.1
  • 7
    • 0027435431 scopus 로고
    • Limitation of exposure to ionizing radiation
    • Bethesda, MD: NCRP
    • National Council on Radiation Protection, Measurements. NCRP Report 116. Limitation of exposure to ionizing radiation. Bethesda, MD: NCRP, 1993.
    • (1993) NCRP Report 116
  • 8
    • 0029050525 scopus 로고
    • Fluoroscopy and the skin: Implications for radiofrequency catheter ablation
    • Nahass GT. Fluoroscopy and the skin: Implications for radiofrequency catheter ablation. Am J Cardiol 1995;76:174-175.
    • (1995) Am J Cardiol , vol.76 , pp. 174-175
    • Nahass, G.T.1
  • 9
    • 0031845985 scopus 로고    scopus 로고
    • Predictors of fluoroscopy time and estimated radiation exposure during radiofrequency catheter ablation procedures
    • Rosenthal LS, Mahesh M, Beck TJ, et al. Predictors of fluoroscopy time and estimated radiation exposure during radiofrequency catheter ablation procedures. Am J Cardiol 1998;82:451-457.
    • (1998) Am J Cardiol , vol.82 , pp. 451-457
    • Rosenthal, L.S.1    Mahesh, M.2    Beck, T.J.3
  • 10
    • 0036147427 scopus 로고    scopus 로고
    • Significant reduction of radiation exposure to operator and staff during cardiac interventions by analysis of radiation leakage and improved lead shielding
    • Kuon E, Schmitt M, Dahm J. Significant reduction of radiation exposure to operator and staff during cardiac interventions by analysis of radiation leakage and improved lead shielding. Am J Cardiol 2002;89:44-49.
    • (2002) Am J Cardiol , vol.89 , pp. 44-49
    • Kuon, E.1    Schmitt, M.2    Dahm, J.3
  • 11
    • 0025008635 scopus 로고
    • Effect of pulsed progressive fluoroscopy on reduction of radiation dose in the cardiac catheterization laboratory
    • Holmes DR, Wondrow MA, Gray JE, et al. Effect of pulsed progressive fluoroscopy on reduction of radiation dose in the cardiac catheterization laboratory. J Am Coll Cardiol 1990;15:159-162.
    • (1990) J Am Coll Cardiol , vol.15 , pp. 159-162
    • Holmes, D.R.1    Wondrow, M.A.2    Gray, J.E.3
  • 12
    • 0028285830 scopus 로고
    • Reduction in radiation exposure while maintaining high-quality fluoroscopic images during interventional cardiology using novel x-ray tube technology with extra beam filtering
    • Den Boer A, De Feyter PJ, Hummel WA, et al. Reduction in radiation exposure while maintaining high-quality fluoroscopic images during interventional cardiology using novel x-ray tube technology with extra beam filtering. Circulation 1994;89:2710-2714.
    • (1994) Circulation , vol.89 , pp. 2710-2714
    • Den Boer, A.1    De Feyter, P.J.2    Hummel, W.A.3
  • 13
    • 0036135651 scopus 로고    scopus 로고
    • Using a sterile disposable protective surgical drape for reduction of radiation exposure to interventionalists
    • King JN, Champlin AM, Kelsey CA, Tripp DA. Using a sterile disposable protective surgical drape for reduction of radiation exposure to interventionalists. Am J Radiol 2002;178:153-157.
    • (2002) Am J Radiol , vol.178 , pp. 153-157
    • King, J.N.1    Champlin, A.M.2    Kelsey, C.A.3    Tripp, D.A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.