Initial clinical experience with a hand-held device (Thrombocheck©) for the detection of bileaflet prosthetic valve malfunction

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ARTICLE; CONTROLLED STUDY; DEVICE; FEMALE; HEART FUNCTION; HEART VALVE PROSTHESIS; HEART VALVE REPLACEMENT; HUMAN; MAJOR CLINICAL STUDY; MALE; PRIORITY JOURNAL; TRANSTHORACIC ECHOCARDIOGRAPHY; VALVULAR HEART DISEASE; AMBULATORY MONITORING; ECHOCARDIOGRAPHY; EVALUATION; FIBRINOLYTIC THERAPY; HEART AUSCULTATION; HEART VALVE; INSTRUMENTATION; MIDDLE AGED; PROGNOSIS; PROSTHESIS FAILURE; SENSITIVITY AND SPECIFICITY; THROMBOEMBOLISM;

EID: 27744504524     PISSN: 09668519     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (6)

References (11)
  • 1
    • 2442644342 scopus 로고    scopus 로고
    • Complications of prosthetic heart valves
    • Vesey JM, Otto CM. Complications of prosthetic heart valves. Curr Cardiol Rep 2004;6:106-111
    • (2004) Curr Cardiol Rep , vol.6 , pp. 106-111
    • Vesey, J.M.1    Otto, C.M.2
  • 2
    • 0020534839 scopus 로고
    • Sound spectrographic studies in the diagnosis of dysfunctions of mechanical heart valve prostheses (Björk-Shiley prostheses)
    • Ebner E, Sehner J, Eger H, Ursinus W. Sound spectrographic studies in the diagnosis of dysfunctions of mechanical heart valve prostheses (Björk-Shiley prostheses). Z Kardiol 1983;72:174-179
    • (1983) Z Kardiol , vol.72 , pp. 174-179
    • Ebner, E.1    Sehner, J.2    Eger, H.3    Ursinus, W.4
  • 4
    • 0032134176 scopus 로고    scopus 로고
    • Spectral analysis of heart valve sound for detection of prosthetic valve diseases
    • Kim SH, Lee HJ, Chang BC. Spectral analysis of heart valve sound for detection of prosthetic valve diseases. Yonsei Med J 1998;39:302-308
    • (1998) Yonsei Med J , vol.39 , pp. 302-308
    • Kim, S.H.1    Lee, H.J.2    Chang, B.C.3
  • 5
    • 0029002079 scopus 로고
    • Acoustic analysis of the closing sounds of implanted prosthetic heart valves
    • Reynolds KJ, Stephen RO. Acoustic analysis of the closing sounds of implanted prosthetic heart valves. J Acoust Soc Am 1995;98:69-77
    • (1995) J Acoust Soc Am , vol.98 , pp. 69-77
    • Reynolds, K.J.1    Stephen, R.O.2
  • 6
    • 4143144161 scopus 로고    scopus 로고
    • Home monitoring of patients after prosthetic valve surgery - experimental background and first clinical attempts
    • Fritzsche D, Eitz T, Grimmig O, Brensing A, Minami K, Korfer R. Home monitoring of patients after prosthetic valve surgery - experimental background and first clinical attempts. Thorac Cardiovasc Surg 2004;52:211-217
    • (2004) Thorac Cardiovasc Surg , vol.52 , pp. 211-217
    • Fritzsche, D.1    Eitz, T.2    Grimmig, O.3    Brensing, A.4    Minami, K.5    Korfer, R.6
  • 7
    • 0041561015 scopus 로고    scopus 로고
    • Acoustic phenomena and valve dysfunction in cardiac prostheses: Data acquisition and collection via the Internet
    • Eitz T, Fritzsche D, Grimmig O, et al. Acoustic phenomena and valve dysfunction in cardiac prostheses: Data acquisition and collection via the Internet. J Heart Valve Dis 2003;12:414-419
    • (2003) J Heart Valve Dis , vol.12 , pp. 414-419
    • Eitz, T.1    Fritzsche, D.2    Grimmig, O.3
  • 8
    • 0036315574 scopus 로고    scopus 로고
    • Feasibility of 2-dimensional bileaflet valve imaging: A prospective transthoracic echocardiographic study
    • Shapira Y, Vaturi M, Perlmuter M, Sagie A. Feasibility of 2-dimensional bileaflet valve imaging: A prospective transthoracic echocardiographic study. J Heart Valve Dis 2002;11:576-582
    • (2002) J Heart Valve Dis , vol.11 , pp. 576-582
    • Shapira, Y.1    Vaturi, M.2    Perlmuter, M.3    Sagie, A.4
  • 9
    • 0030975663 scopus 로고    scopus 로고
    • Hemodynamic evaluation of the CarboMedics R, St. Jude Medical HP and Sorin-Bicarbon valve in patients with small aortic annulus
    • Noera G, Pensa P, Lamarra M, Mascagni R, Cremonesi A, Balestra G. Hemodynamic evaluation of the CarboMedics R, St. Jude Medical HP and Sorin-Bicarbon valve in patients with small aortic annulus. Eur J Cardiothorac Surg 1997;11:473-476
    • (1997) Eur J Cardiothorac Surg , vol.11 , pp. 473-476
    • Noera, G.1    Pensa, P.2    Lamarra, M.3    Mascagni, R.4    Cremonesi, A.5    Balestra, G.6
  • 10
    • 9144272407 scopus 로고    scopus 로고
    • Prosthetic valve thrombolysis - Role of Transesophageal Echocardiography (PRO-TEE) Registry Investigators. Transesophageal echocardiography improves risk assessment of thrombolysis of prosthetic valve thrombosis: Results of the international PRO-TEE registry
    • Tong AT, Roudaut R, Ozkan M, et al. Prosthetic valve thrombolysis - Role of Transesophageal Echocardiography (PRO-TEE) Registry Investigators. Transesophageal echocardiography improves risk assessment of thrombolysis of prosthetic valve thrombosis: Results of the international PRO-TEE registry. J Am Coll Cardiol 2004;43:77-784
    • (2004) J Am Coll Cardiol , vol.43 , pp. 77-784
    • Tong, A.T.1    Roudaut, R.2    Ozkan, M.3
  • 11
    • 0033664161 scopus 로고    scopus 로고
    • Thrombolytic therapy for prosthetic valve thrombosis: Short- and long-term results
    • Gupta D, Kothari SS, Bahl VK, et al. Thrombolytic therapy for prosthetic valve thrombosis: Short- and long-term results. Am Heart J 2000;140:906-916
    • (2000) Am Heart J , vol.140 , pp. 906-916
    • Gupta, D.1    Kothari, S.S.2    Bahl, V.K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.