메뉴 건너뛰기




Volumn 73, Issue 2-4, 2005, Pages 181-186

Experimental study of DEMO helium cooled divertor target mock-ups to estimate their thermal and pumping efficiencies

Author keywords

DEMO divertor; Helium cooling; High heat flux experiments

Indexed keywords

COMPUTATIONAL FLUID DYNAMICS; COOLING; HELIUM; MASS TRANSFER; PLASMAS; TUNGSTEN;

EID: 27744451866     PISSN: 09203796     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.fusengdes.2005.06.349     Document Type: Article
Times cited : (17)

References (2)