메뉴 건너뛰기




Volumn 207, Issue 3, 2005, Pages 197-202

Clinical application of acceleration sensor to detect the swing phase of stroke gait in functional electrical stimulation

Author keywords

Foot drop; Functional electrical stimulation; Hemiplegia; Neural network; Sensor

Indexed keywords

ACCURACY; ADULT; AGED; ARTICLE; ARTIFICIAL NEURAL NETWORK; CEREBROVASCULAR ACCIDENT; CLINICAL ARTICLE; COMPUTER PROGRAM; CONTROLLED STUDY; ELECTRODE; ELECTROSTIMULATION; FUNCTIONAL ASSESSMENT; GAIT DISORDER; HEEL; HEMIPLEGIA; HUMAN; INTERMETHOD COMPARISON; MALE; NERVE STIMULATION; PERONEUS NERVE; SENSOR;

EID: 27744440187     PISSN: 00408727     EISSN: 13493329     Source Type: Journal    
DOI: 10.1620/tjem.207.197     Document Type: Article
Times cited : (47)

References (14)
  • 4
    • 1542409174 scopus 로고    scopus 로고
    • Evaluating robustness of gait event detection based on machine learning and natural sensors
    • Hansen, M., Haugland, M.K. & Sinkjaer, T. (2004) Evaluating robustness of gait event detection based on machine learning and natural sensors. IEEE Trans. Neural Systems Rehabil. Eng., 12, 81-88.
    • (2004) IEEE Trans. Neural Systems Rehabil. Eng. , vol.12 , pp. 81-88
    • Hansen, M.1    Haugland, M.K.2    Sinkjaer, T.3
  • 5
    • 27744521927 scopus 로고
    • Radio frequency switch, orthotic systems using functional electrical stimulation and myoelectric control
    • Final Report of Project 19-P-58391-F-01. Dept. Health, Education and Welfare, Washington
    • Jeglic, A., Vavken, E., Ursic, I. & Smolnik, M. (1971) Radio frequency switch, orthotic systems using functional electrical stimulation and myoelectric control. In: Final Report of Project 19-P-58391-F-01. Dept. Health, Education and Welfare, Washington, pp. 17-23.
    • (1971) , pp. 17-23
    • Jeglic, A.1    Vavken, E.2    Ursic, I.3    Smolnik, M.4
  • 7
    • 0033060645 scopus 로고    scopus 로고
    • Adaptive Restriction Rules Provide Functional and Safe Stimulation Pattern for Foot Drop Correction
    • Kostov, A., Hansen, M., Haugland, M. & Sinkjaer, T. (1999) Adaptive Restriction Rules Provide Functional and Safe Stimulation Pattern for Foot Drop Correction. Artificial Organs., 23, 443-446.
    • (1999) Artificial Organs , vol.23 , pp. 443-446
    • Kostov, A.1    Hansen, M.2    Haugland, M.3    Sinkjaer, T.4
  • 8
    • 73049136842 scopus 로고
    • Functional electrotherapy, stimulation of the peroneal nerve synchronized with the swing phase of the gait of hemiplegic patients
    • Liberson, W.T., Holmquest, H., Scott, D. & Dow, M. (1961) Functional electrotherapy, stimulation of the peroneal nerve synchronized with the swing phase of the gait of hemiplegic patients. Arch. Phys. Med. Rehabil., 42, 101-105.
    • (1961) Arch. Phys. Med. Rehabil. , vol.42 , pp. 101-105
    • Liberson, W.T.1    Holmquest, H.2    Scott, D.3    Dow, M.4
  • 9
    • 0242662564 scopus 로고    scopus 로고
    • The use of accelerometry to detect heel contact events for use as a sensor in FES assisted walking
    • Mansfield, A. & Lyons, G.M. (2003) The use of accelerometry to detect heel contact events for use as a sensor in FES assisted walking. Med. Eng. Physics, 25, 879-885.
    • (2003) Med. Eng. Physics , vol.25 , pp. 879-885
    • Mansfield, A.1    Lyons, G.M.2
  • 10
    • 0029859791 scopus 로고    scopus 로고
    • Clinical experience of functional electrical stimulation in complete paraplegia
    • Shimada, Y., Sato, K., Abe, E., Kagaya, H., Ebata, K., Oba, M. & Sato, M. (1996a) Clinical experience of functional electrical stimulation in complete paraplegia. Spinal Cord., 34, 615-619.
    • (1996) Spinal Cord , vol.34 , pp. 615-619
    • Shimada, Y.1    Sato, K.2    Abe, E.3    Kagaya, H.4    Ebata, K.5    Oba, M.6    Sato, M.7
  • 11
    • 0029847310 scopus 로고    scopus 로고
    • Clinical use of percutaneous intramuscular electrodes for functional electrical stimulation
    • Shimada, Y., Sato, K., Kagaya, H., Konishi, N., Miyamoto, S. & Matsunaga, T. (1996b) Clinical use of percutaneous intramuscular electrodes for functional electrical stimulation. Arch. Phys. Med. Rehabil., 77, 1014-1018.
    • (1996) Arch. Phys. Med. Rehabil. , vol.77 , pp. 1014-1018
    • Shimada, Y.1    Sato, K.2    Kagaya, H.3    Konishi, N.4    Miyamoto, S.5    Matsunaga, T.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.