메뉴 건너뛰기




Volumn 1, Issue 1, 2004, Pages 43-63

Review of robotic fixtures for minimally invasive surgery

Author keywords

active endoscopes; articulated end effectors; autonomous catheters; co robotic aids; miniature instruments; minimally invasive surgery; remote surgery

Indexed keywords

COPYRIGHTS; MEMS; PROBLEM SOLVING; ROBOTIC SURGERY; SURGICAL EQUIPMENT;

EID: 27744436840     PISSN: 14785951     EISSN: 1478596X     Source Type: Journal    
DOI: 10.1002/rcs.5     Document Type: Review
Times cited : (51)

References (46)
  • 1
    • 85163147419 scopus 로고    scopus 로고
    • Conception d'un micro robot à actionneur électropneumatique pour l'inspection intratubulaire (PhD thesis). Institut National des Sciences Appliques de Lyon, France;, Available from
    • Anthierens C. Conception d'un micro robot à actionneur électropneumatique pour l'inspection intratubulaire (PhD thesis). Institut National des Sciences Appliques de Lyon, France; 2000. Available from: http://csidoc.insa-lyon.fr/these/1999/anthierens/index.html
    • (2000)
    • Anthierens, C.1
  • 9
    • 0034246488 scopus 로고    scopus 로고
    • A Fully Autonomous Microrobotic Endoscopy System,''
    • Available from
    • Asari VK, Sanjiv K, Irwan MK. A Fully Autonomous Microrobotic Endoscopy System,'' Journal of Intelligent and Robotic Systems 1999; 28: 325–41. Available from: http://www.kluweronline.com/article.asp?PIPS=253914
    • (1999) Journal of Intelligent and Robotic Systems , vol.28 , pp. 325-341
    • Asari, V.K.1    Sanjiv, K.2    Irwan, M.K.3
  • 12
    • 0036473419 scopus 로고    scopus 로고
    • Science and Technology of Shape-Memory Alloys; New Developments
    • Feb. p., Available from
    • Otsuka K, Kakeshita T. Science and Technology of Shape-Memory Alloys; New Developments. MRS Bulletin; 2002 Feb. p. 95. Available from: http://www.mrs.org/publications/bulletin/2002/feb/Feb02_Intro.pdf
    • (2002) MRS Bulletin , pp. 95
    • Otsuka, K.1    Kakeshita, T.2
  • 14
    • 85163155742 scopus 로고    scopus 로고
    • Evaluation de Systemes Robotiques et Comportements Complexes par Algorithmes Evolutionnaires (PhD Thesis). University Pierre et Marie Curie, France;, Available from
    • Chapelle F. Evaluation de Systemes Robotiques et Comportements Complexes par Algorithmes Evolutionnaires (PhD Thesis). University Pierre et Marie Curie, France; 2002. Available from: http://perso.club-internet.fr/chapelle/These_Chapelle.pdf
    • (2002)
    • Chapelle, F.1
  • 15
    • 78650361976 scopus 로고    scopus 로고
    • Virtual Endoscopy: from simulation to optimization of an active endoscope
    • p., Available from
    • Kuhl C, Dumont G. Virtual Endoscopy: from simulation to optimization of an active endoscope. Proceedings of the Modelling & Simulation for Computer-aided Medicine and Surgery 2002; 12, p. 84–93. Available from: http://www.edpsciences.org/articlesproc/Vol.12/PDF/Kuhl.pdf
    • (2002) Proceedings of the Modelling & Simulation for Computer-aided Medicine and Surgery , vol.12 , pp. 84-93
    • Kuhl, C.1    Dumont, G.2
  • 17
    • 1342346346 scopus 로고    scopus 로고
    • Analytical modeling of a segmented unimorph actuator using electrostrictive (pvdf-trfe) copolymer
    • p
    • Frecker MI, Aguilera WM. Analytical modeling of a segmented unimorph actuator using electrostrictive (pvdf-trfe) copolymer. Smart material and structures. 2003; p. 82–91.
    • (2003) Smart material and structures , pp. 82-91
    • Frecker, M.I.1    Aguilera, W.M.2
  • 18
    • 85163161545 scopus 로고    scopus 로고
    • Study report—Neuro-endoscopic manipulator (PhD thesis). Mechanical Engineering Imperial College of London;, Available from
    • Starkie S. Study report—Neuro-endoscopic manipulator (PhD thesis). Mechanical Engineering Imperial College of London; 1998. Available from: http://www.me.ic.ac.uk/case/mim/projects/roboscope/Study_Report.pdf
    • (1998)
    • Starkie, S.1
  • 19
    • 0348040293 scopus 로고    scopus 로고
    • Proceedings of the IEEE/RSJ Intl. Conference on Intelligent Robots and Systems., p., Available from
    • Berkelman P, Boidard E, Cinquin P, Troccaz J. LER: The Light Endoscope Robot. Proceedings of the IEEE/RSJ Intl. Conference on Intelligent Robots and Systems. 2003; p. 2835–40. Available from: http://prism.mem.drexel.edu/desai/MRI/Paper26.pdf
    • (2003) LER: The Light Endoscope Robot , pp. 2835-2840
    • Berkelman, P.1    Boidard, E.2    Cinquin, P.3    Troccaz, J.4
  • 20
    • 85163219764 scopus 로고    scopus 로고
    • Proceedings of the 4th Japan-France Congress and 2nd Asia-Europe Congress on Mechatronics., 1 p
    • Kato S, Hirayama T. Fabrication of a High Speed In-Pipe Mobile Micro Machine. Proceedings of the 4th Japan-France Congress and 2nd Asia-Europe Congress on Mechatronics. 1998, 1: p. 429–32.
    • (1998) Fabrication of a High Speed In-Pipe Mobile Micro Machine , pp. 429-432
    • Kato, S.1    Hirayama, T.2
  • 23
    • 85163162250 scopus 로고    scopus 로고
    • Proceedings of the National Congress on Theoretical and Applied Mechanics;, p., Available from
    • Peirs J, Reynaerts D, Van Brussel H. Shape memory alloy micro- actuators for medical applications. Proceedings of the National Congress on Theoretical and Applied Mechanics; 1997. p. 389–92. Available from: http://www.mech.kuleuven.ac.be/pma/research/mpe/pub/medic/Nationaal_congres_mechanica.pdf
    • (1997) Shape memory alloy micro- actuators for medical applications , pp. 389-392
    • Peirs, J.1    Reynaerts, D.2    Van Brussel, H.3
  • 25
    • 85163174942 scopus 로고    scopus 로고
    • Proceedings of the 2001 IEEE/RSJ International Conference on Intelligent Robots and Systems;, p., Available from
    • Young ML, Jinhee L, Jisang P, Byungkyu K, Jong-Oh P, Soo Hyun K, Yeh-Sun H. A Self-Propelling Endoscopic System. Proceedings of the 2001 IEEE/RSJ International Conference on Intelligent Robots and Systems; 2001. p. 1117–22. Available from: http://microbot.kist.re.kr/publication/0412_lim.pdf
    • (2001) A Self-Propelling Endoscopic System , pp. 1117-1122
    • Young, M.L.1    Jinhee, L.2    Jisang, P.3    Byungkyu, K.4    Jong-Oh, P.5    Soo Hyun, K.6    Yeh-Sun, H.7
  • 27
    • 0034945671 scopus 로고    scopus 로고
    • From knife to needle to nothing: the waning of the wound
    • Available from
    • Clayman RV. From knife to needle to nothing: the waning of the wound. Official Journal of the Brazilian Society of Urology 2001; 27(3):209–14. Available from: http://www.brazjurol.com.br/maio_2001/Clayman_209_214.pdf
    • (2001) Official Journal of the Brazilian Society of Urology , vol.27 , Issue.3 , pp. 209-214
    • Clayman, R.V.1
  • 31
    • 85163165324 scopus 로고    scopus 로고
    • Available from
    • Imagyn (homepage on the Internet). Available from: http://www.cybelius.com/showcase/modles/articulator_cult/Model3.htm
    • Imagyn (homepage on the Internet)
  • 33
  • 36
    • 85163191605 scopus 로고    scopus 로고
    • Robot-Assisted Surgery: A Review
    • University of, Available from
    • Govindarajan. Robot-Assisted Surgery: A Review. University of Toronto Medical Journal 108. 2001; 78(2). Available from: http://www.utmj.org/issues/78.2/Surgery.pdf
    • (2001) Toronto Medical Journal , vol.108 , Issue.2
  • 37
    • 85163172181 scopus 로고    scopus 로고
    • Virtual Reality, Augmented Reality & Robotics for Computer Assisted Surgery in Laparoscopic Surgery (tutorial)
    • Available from
    • Soler L. Virtual Reality, Augmented Reality & Robotics for Computer Assisted Surgery in Laparoscopic Surgery (tutorial). Euron Summer School on Surgical Robotics; 2003. Available from: http://www.lirmm.fr/manifs/UEE/docs/slides/Soler.pdf
    • (2003) Euron Summer School on Surgical Robotics
    • Soler, L.1
  • 41
    • 85163185671 scopus 로고    scopus 로고
    • Motion Compensation in Minimally Invasive Robotic Surgery (PhD thesis). Technical University of Munich;, Available from
    • Ortmaier T. Motion Compensation in Minimally Invasive Robotic Surgery (PhD thesis). Technical University of Munich; 2003. Available from: http://www.robotic.dlr.de/Tobias.Ortmaier/
    • (2003)
    • Ortmaier, T.1
  • 44
    • 85163174895 scopus 로고    scopus 로고
    • Proceedings of the IEEE/RSJ International Conference on Intelligent Robots and Systems;, p., Available from
    • Dong-Soo K, Ki Young W, Se Kyong S, Wan Soo K, Hyung Suck C. Microsurgical telerobot system. Proceedings of the IEEE/RSJ International Conference on Intelligent Robots and Systems; 1998. p. 945–50. Available from: http://robot.kaist.ac.kr/∼songsk/paper/iros1998.pdf
    • (1998) Microsurgical telerobot system , pp. 945-950
    • Dong-Soo, K.1    Ki Young, W.2    Se Kyong, S.3    Wan Soo, K.4    Hyung Suck, C.5
  • 46
    • 0345412678 scopus 로고    scopus 로고
    • A family of co-robotic surgical set-ups
    • Available from
    • Cepolina F, Michelini RC. A family of co-robotic surgical set-ups. Industrial Robot: An International Journal 2003;30(6):564–74. Available from: http://iris.emeraldinsight.com/vl=655971/cl=51/nw=1/rpsv/cgi-bin/emeraldft doi:10.1108/01439910310506837
    • (2003) Industrial Robot: An International Journal , vol.30 , Issue.6 , pp. 564-574
    • Cepolina, F.1    Michelini, R.C.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.