메뉴 건너뛰기




Volumn 5, Issue 5, 2005, Pages 1120-1125

Microanalysis system for pO 2, pCO 2, and pH constructed with stacked modules

Author keywords

TAS; Bubble; Carbon dioxide; Diaphragm; Module; Oxygen; pH; Reference electrode; Sampling

Indexed keywords

ΜTAS; FLOW CHANNEL; MODULE; REFERENCE ELECTRODES;

EID: 27744434782     PISSN: 1530437X     EISSN: None     Source Type: Journal    
DOI: 10.1109/JSEN.2005.853596     Document Type: Article
Times cited : (7)

References (23)
  • 1
    • 0031812831 scopus 로고    scopus 로고
    • Electrochemical analysis of clinical blood-gases, gases and vapors
    • C. E. W. Hahn, "Electrochemical analysis of clinical blood-gases, gases and vapors," Analyst, vol. 123, pp. 57R-86R, 1998.
    • (1998) Analyst , vol.123
    • Hahn, C.E.W.1
  • 2
    • 0030088510 scopus 로고    scopus 로고
    • Pro: Is continuous intra-arterial blood gas and pH monitoring justifiable?
    • H. C. Gilbert and J. S. Vender, "Pro: is continuous intra-arterial blood gas and pH monitoring justifiable?," J. Clin. Monit., vol. 12, pp. 179-181, 1996.
    • (1996) J. Clin. Monit. , vol.12 , pp. 179-181
    • Gilbert, H.C.1    Vender, J.S.2
  • 3
    • 0030088509 scopus 로고    scopus 로고
    • Con: Is continuous intra-arterial blood gas and pH monitoring justifiable?
    • J. L. Hoffer and E. A. Norfleet, "Con: is continuous intra-arterial blood gas and pH monitoring justifiable?," J. Clin. Monit., vol. 12, pp. 183-189, 1996.
    • (1996) J. Clin. Monit. , vol.12 , pp. 183-189
    • Hoffer, J.L.1    Norfleet, E.A.2
  • 4
    • 0026868376 scopus 로고
    • Micro flow cell for blood-gas analysis realizing very small sample volume
    • S. Shoji and M. Esashi, "Micro flow cell for blood-gas analysis realizing very small sample volume," Sens. Actuators B, vol. 8, pp. 205-208, 1992.
    • (1992) Sens. Actuators B , vol.8 , pp. 205-208
    • Shoji, S.1    Esashi, M.2
  • 11
    • 27744591935 scopus 로고
    • Evaluation of blood-gas and pH methods on the i-STAT(TM) portable clinical analyzer
    • P. L. Bottjen and M. C. Haven, "Evaluation of blood-gas and pH methods on the i-STAT(TM) portable clinical analyzer," Clin. Chem., vol. 41, p. S196, 1995.
    • (1995) Clin. Chem. , vol.41
    • Bottjen, P.L.1    Haven, M.C.2
  • 12
    • 0032917896 scopus 로고    scopus 로고
    • The portable laboratory: An evaluation of the accuracy and reproducibility of i-STAT (c)
    • D. Bingham, J. Kendall, and M. Clancy, "The portable laboratory: an evaluation of the accuracy and reproducibility of i-STAT (c)," Ann. Clin. Biochem., vol. 36, pp. 66-71, 1999.
    • (1999) Ann. Clin. Biochem. , vol.36 , pp. 66-71
    • Bingham, D.1    Kendall, J.2    Clancy, M.3
  • 13
    • 0000455724 scopus 로고    scopus 로고
    • Thin-film Ag/AgCl structure and operational modes to realize long-term storage
    • H. Suzuki and T. Taura, "Thin-film Ag/AgCl structure and operational modes to realize long-term storage," J. Electrochem. Soc., vol. 148, pp. E468-E474, 2001.
    • (2001) J. Electrochem. Soc. , vol.148
    • Suzuki, H.1    Taura, T.2
  • 14
    • 0032732362 scopus 로고    scopus 로고
    • Microfabricated liquid junction Ag/AgCl reference electrode and its application to a one-chip potentiometric sensor
    • H. Suzuki, H. Shiroishi, S. Sasaki, and I. Karube, "Microfabricated liquid junction Ag/AgCl reference electrode and its application to a one-chip potentiometric sensor," Anal. Chem., vol. 71, pp. 5069-5075, 1999.
    • (1999) Anal. Chem. , vol.71 , pp. 5069-5075
    • Suzuki, H.1    Shiroishi, H.2    Sasaki, S.3    Karube, I.4
  • 15
    • 0001493816 scopus 로고
    • Rapid measurement of the tension of carbon dioxide in blood
    • R. W. Stow, R. F. Baer, and B. F. Randall, "Rapid measurement of the tension of carbon dioxide in blood," Arch. Phys. Med. Rehab., vol. 38, pp. 646-650, 1957.
    • (1957) Arch. Phys. Med. Rehab. , vol.38 , pp. 646-650
    • Stow, R.W.1    Baer, R.F.2    Randall, B.F.3
  • 17
    • 0036307674 scopus 로고    scopus 로고
    • The invention and development of blood gas analysis apparatus
    • J. W. Severinghaus, "The invention and development of blood gas analysis apparatus," Anesthesiol., vol. 97, pp. 253-256, 2002.
    • (2002) Anesthesiol. , vol.97 , pp. 253-256
    • Severinghaus, J.W.1
  • 18
    • 0028773039 scopus 로고
    • Simplified duallumen catheter design for simultaneous potentiometric monitoring of carbon-dioxide and pH
    • M. Telting-Diaz, M. E. Collison, and M. E. Meyerhoff, "Simplified duallumen catheter design for simultaneous potentiometric monitoring of carbon-dioxide and pH," Anal. Chem., vol. 66, pp. 576-583, 1994.
    • (1994) Anal. Chem. , vol.66 , pp. 576-583
    • Telting-Diaz, M.1    Collison, M.E.2    Meyerhoff, M.E.3
  • 19
    • 0035335916 scopus 로고    scopus 로고
    • Bubble-based micropump for electrically conducting liquids
    • X. Geng, H. Yuan, H. N. Oguz, and A. Prosperetti, "Bubble-based micropump for electrically conducting liquids," J. Micromech. Microeng., vol. 11, pp. 270-276, 2001.
    • (2001) J. Micromech. Microeng. , vol.11 , pp. 270-276
    • Geng, X.1    Yuan, H.2    Oguz, H.N.3    Prosperetti, A.4
  • 20
    • 0037115371 scopus 로고    scopus 로고
    • Microfluidic actuation using electrochemically generated bubbles
    • S. Z. Hua, F. Sachs, D. X. Yang, and H. D. Chopra, "Microfluidic actuation using electrochemically generated bubbles," Anal. Chem., vol. 74, pp. 6392-6396, 2002.
    • (2002) Anal. Chem. , vol.74 , pp. 6392-6396
    • Hua, S.Z.1    Sachs, F.2    Yang, D.X.3    Chopra, H.D.4
  • 21
    • 0036544174 scopus 로고    scopus 로고
    • Active microfluidic mixer and gas bubble filter driven by thermal bubble micropump
    • J.-H. Tsai and L. Lin, "Active microfluidic mixer and gas bubble filter driven by thermal bubble micropump," Sens. Actuators A, vol. 97-98, pp. 665-671, 2002.
    • (2002) Sens. Actuators A , vol.97-98 , pp. 665-671
    • Tsai, J.-H.1    Lin, L.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.