메뉴 건너뛰기




Volumn 54, Issue 5, 2005, Pages 1300-1304

Equivalent cross-relaxation rate imaging for sentinel lymph node biopsy in breast carcinoma

Author keywords

Breast cancer; Equivalent cross relaxation rate; Magnetic resonance imaging; Magnetization transfer; Sentinel lymph node

Indexed keywords

BIOPSY; MAGNETIC RESONANCE IMAGING; PATHOLOGY;

EID: 27644580341     PISSN: 07403194     EISSN: None     Source Type: Journal    
DOI: 10.1002/mrm.20685     Document Type: Article
Times cited : (9)

References (18)
  • 1
    • 0036174781 scopus 로고    scopus 로고
    • Clinical role of sentinel lymph node biopsy in breast cancer
    • Keshtgar MR, Ell PJ. Clinical role of sentinel lymph node biopsy in breast cancer. Lancet Oncol 2002;3:105-110.
    • (2002) Lancet Oncol , vol.3 , pp. 105-110
    • Keshtgar, M.R.1    Ell, P.J.2
  • 3
    • 0036892478 scopus 로고    scopus 로고
    • Combined MR lymphangiography and MR imaging-guided needle localization of sentinel lymph nodes using Gadomer-17
    • Torchia MG, Misselwitz B. Combined MR lymphangiography and MR imaging-guided needle localization of sentinel lymph nodes using Gadomer-17. AJR Am J Roentgenol 2002;179:1561-1565.
    • (2002) AJR Am J Roentgenol , vol.179 , pp. 1561-1565
    • Torchia, M.G.1    Misselwitz, B.2
  • 4
    • 0037240205 scopus 로고    scopus 로고
    • Localization of breast sentinel lymph nodes by MR lymphography with a conventional gadolinium contrast agent. Preliminary observations in dogs and humans
    • Suga K, Yuan Y, Ogasawara N, Okada M, Matsunaga N. Localization of breast sentinel lymph nodes by MR lymphography with a conventional gadolinium contrast agent. Preliminary observations in dogs and humans. Acta Radiol 2003;44:35-42.
    • (2003) Acta Radiol , vol.44 , pp. 35-42
    • Suga, K.1    Yuan, Y.2    Ogasawara, N.3    Okada, M.4    Matsunaga, N.5
  • 6
    • 0141506083 scopus 로고    scopus 로고
    • Comparison of dendrimer-based macromolecular contrast agents for dynamic micro-magnetic resonance lymphangiography
    • Kobayashi H, Kawamoto S, Choyke PL, Sato N, Brechbiel MW. Comparison of dendrimer-based macromolecular contrast agents for dynamic micro-magnetic resonance lymphangiography. Magn Reson Med 2003;50:758-766.
    • (2003) Magn Reson Med , vol.50 , pp. 758-766
    • Kobayashi, H.1    Kawamoto, S.2    Choyke, P.L.3    Sato, N.4    Brechbiel, M.W.5
  • 8
    • 0029983511 scopus 로고    scopus 로고
    • Magnetization transfer or spin lock? An investigation of off-resonance saturation pulse imaging with varying frequency offset
    • Ulmer JL, Mathews VP, Hamilton CA, Elster AD, Moran PR. Magnetization transfer or spin lock? An investigation of off-resonance saturation pulse imaging with varying frequency offset. AJNR Am J Neuroradiol 1996;17:805-819.
    • (1996) AJNR Am J Neuroradiol , vol.17 , pp. 805-819
    • Ulmer, J.L.1    Mathews, V.P.2    Hamilton, C.A.3    Elster, A.D.4    Moran, P.R.5
  • 12
    • 0032938485 scopus 로고    scopus 로고
    • The magnetization transfer characteristics of human breast tissues: An in vitro NMR study
    • Callicott C, Thomas JM, Goode AW. The magnetization transfer characteristics of human breast tissues: an in vitro NMR study. Phys Med Biol 1999;44:1147-1154.
    • (1999) Phys Med Biol , vol.44 , pp. 1147-1154
    • Callicott, C.1    Thomas, J.M.2    Goode, A.W.3
  • 13
    • 0001133187 scopus 로고
    • Proton spin relaxation in biopolymers at high magnetic field
    • Akasaka K, Ishima R, Shibata S. Proton spin relaxation in biopolymers at high magnetic field. Physica B: Condensed Matter 1990;164:163-179.
    • (1990) Physica B: Condensed Matter , vol.164 , pp. 163-179
    • Akasaka, K.1    Ishima, R.2    Shibata, S.3
  • 14
    • 0001818023 scopus 로고
    • Longitudinal relaxation of protons under cross saturation and spin diffusion
    • Akasaka K. Longitudinal relaxation of protons under cross saturation and spin diffusion. J Magn Reson 1981;45:337-343.
    • (1981) J Magn Reson , vol.45 , pp. 337-343
    • Akasaka, K.1
  • 15


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.