메뉴 건너뛰기




Volumn 178, Issue 1-3 SPEC. ISS., 2005, Pages 247-260

Basic options and two case studies for retrofitting hollow fiber elements by spiral-wound RO technology

Author keywords

Hollow fiber; Retrofitting; Reverse osmosis; Spiral wound

Indexed keywords

MEMBRANES; RETROFITTING; REVERSE OSMOSIS; SEAWATER; THERMAL EFFECTS; WATER FILTRATION; WATER TREATMENT PLANTS;

EID: 27644559086     PISSN: 00119164     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.desal.2004.12.021     Document Type: Article
Times cited : (8)

References (21)
  • 1
    • 33846436033 scopus 로고    scopus 로고
    • History, success and recent developments in seawater reverse osmosis desalting in Spain - Using DuPont reverse osmosis technology
    • M. Cirera C.P. Shields History, success and recent developments in seawater reverse osmosis desalting in Spain - using DuPont reverse osmosis technology IDA Proc., Madrid 2 1997 421-439
    • (1997) IDA Proc., Madrid , vol.2 , pp. 421-439
    • Cirera, M.1    Shields, C.P.2
  • 2
    • 84900661377 scopus 로고    scopus 로고
    • The Hollow-Fiber CartridgeTM development and commercialization of an entirely new reverse osmosis device/technology
    • T.J. Eckman C.P. Shields J.W. Stranz J.M. Wright III The Hollow-Fiber CartridgeTM development and commercialization of an entirely new reverse osmosis device/technology IDA Proc., Madrid 3 1997 441-458
    • (1997) IDA Proc., Madrid , vol.3 , pp. 441-458
    • Eckman, T.J.1    Shields, C.P.2    Stranz, J.W.3    Wright, J.M.4
  • 3
    • 8644232930 scopus 로고
    • The Malta seawater RO facility
    • First World Congress on Desalination and Water Re-use. Florence, Italy
    • W.T. Andrews R.A. Bergman The Malta seawater RO facility First World Congress on Desalination and Water Re-use Florence, Italy 1983
    • (1983)
    • Andrews, W.T.1    Bergman, R.A.2
  • 4
    • 0028450495 scopus 로고
    • The TWINTM permeator - Development and commercialization of a new RO device
    • Th.J. Eckman I. Moch C.P. Shields The TWINTM permeator - development and commercialization of a new RO device Desalination 96 1994 11-22
    • (1994) Desalination , vol.96 , pp. 11-22
    • Eckman, Th.J.1    Moch, I.2    Shields, C.P.3
  • 5
    • 0028450520 scopus 로고
    • Reliable supply of drinking water through use of high performance B-10 "TWIN" permeators. A one year case history at Das Island, UAE
    • H.W. Pohland A.B. Hamida K. Chida Reliable supply of drinking water through use of high performance B-10 "TWIN" permeators. A one year case history at Das Island, UAE Desahution 96 1994 303-310
    • (1994) Desahution , vol.96 , pp. 303-310
    • Pohland, H.W.1    Hamida, A.B.2    Chida, K.3
  • 7
    • 0002430765 scopus 로고
    • Design and operation of a 1.2 MGD (4542 CUMD) open sea intake plant in the Caribbean
    • W.Chr. Barendsen I. Moch Design and operation of a 1.2 MGD (4542 CUMD) open sea intake plant in the Caribbean IDE Proc., Abu Dhabi 3 1995 25-40
    • (1995) IDE Proc., Abu Dhabi , vol.3 , pp. 25-40
    • Barendsen, W.Chr.1    Moch, I.2
  • 8
    • 27644432091 scopus 로고
    • Holow fiber permeators and reverse osmosis
    • I. Moch Holow fiber permeators and reverse osmosis Desalination and Water Reuse 2/3 1992 30-37
    • (1992) Desalination and Water Reuse , vol.2 , Issue.3 , pp. 30-37
    • Moch, I.1
  • 9
    • 8644284185 scopus 로고    scopus 로고
    • Reducing energy consumption in seawater desalination
    • M. Busch W.E. Mickols Reducing energy consumption in seawater desalination Desalination 165 2004 299-312
    • (2004) Desalination , vol.165 , pp. 299-312
    • Busch, M.1    Mickols, W.E.2
  • 10
    • 8644277602 scopus 로고    scopus 로고
    • Innovaciones Tecnológicas en la Osmosis Inversa de Agua de Mar
    • IV Congreso nacional AEDyR, Desalación y Reutilización Mirando al Futuro Las Palmas de Gran Canaria
    • A. Gorenflo J.A. Redondo M. Busch A. Casañas J. Johnson Innovaciones Tecnológicas en la Osmosis Inversa de Agua de Mar IV Congreso nacional AEDyR, Desalación y Reutilización Mirando al Futuro Las Palmas de Gran Canaria 2003
    • (2003)
    • Gorenflo, A.1    Redondo, J.A.2    Busch, M.3    Casañas, A.4    Johnson, J.5
  • 11
    • 27644518228 scopus 로고    scopus 로고
    • Etapas de concentrador de salmuera de la Planta Desaladora del Sureste de Gran Canaria: Primer año de funcionamiento
    • IV Congreso nacional AEDyR, Desalación y Reutilización Mirando al Futuro Las Palmas de Gran Canaria
    • A. Casañas M. Busch M. Sanchez R.S. Ramirez Etapas de concentrador de salmuera de la Planta Desaladora del Sureste de Gran Canaria: Primer año de funcionamiento IV Congreso nacional AEDyR, Desalación y Reutilización Mirando al Futuro Las Palmas de Gran Canaria 2003
    • (2003)
    • Casañas, A.1    Busch, M.2    Sanchez, M.3    Ramirez, R.S.4
  • 12
    • 0035921786 scopus 로고    scopus 로고
    • Operation and reliability of very high-recovery seawater desalination technologies by brine conversion two-stage RO desalination system
    • M. Kurihara H. Yamamura T. Nakanishi S. Jinno Operation and reliability of very high-recovery seawater desalination technologies by brine conversion two-stage RO desalination system Desalination 138 2001 191-199
    • (2001) Desalination , vol.138 , pp. 191-199
    • Kurihara, M.1    Yamamura, H.2    Nakanishi, T.3    Jinno, S.4
  • 13
    • 0043267711 scopus 로고    scopus 로고
    • Conversion from hollow fiber to spiral technology in large seawater RO systems - Process design and economics
    • V. Polasek S. Talo T. Sharif Conversion from hollow fiber to spiral technology in large seawater RO systems - process design and economics Desalination 156 2003 239-247
    • (2003) Desalination , vol.156 , pp. 239-247
    • Polasek, V.1    Talo, S.2    Sharif, T.3
  • 14
    • 27644461734 scopus 로고    scopus 로고
    • The first successful operation of a single stage seawater RO plant exceeding 50% recovery in the Middle East
    • 6th Gulf Water Conference Riyadh, Saudi Arabia
    • S.A. Basha K. Chida M. Nishda N. Fujiwara A. Kumano The first successful operation of a single stage seawater RO plant exceeding 50% recovery in the Middle East, 6th Gulf Water Conference Riyadh, Saudi Arabia 2003
    • (2003)
    • Basha, S.A.1    Chida, K.2    Nishda, M.3    Fujiwara, N.4    Kumano, A.5
  • 15
    • 0033226351 scopus 로고    scopus 로고
    • Experimental test of TOYOBO membranes for seawater desalination at Las Palmas, Spain
    • A. Munoz Elguera A. Nunez M. Nishida Experimental test of TOYOBO membranes for seawater desalination at Las Palmas, Spain Desalination 125 1999 55-64
    • (1999) Desalination , vol.125 , pp. 55-64
    • Munoz Elguera, A.1    Nunez, A.2    Nishida, M.3
  • 17
    • 27644530834 scopus 로고    scopus 로고
    • The Dow Chemical literature archive, Membrane System Design Guidelines for 8-inch FILMTEC Elements
    • Form No. 609-21010-304, Midland 2004
    • The Dow Chemical literature archive, Membrane System Design Guidelines for 8-inch FILMTEC Elements, Form No. 609-21010-304, Midland 2004
    • (2004)
  • 18
    • 0034068911 scopus 로고    scopus 로고
    • Cost modeling and estimation of crossflow membrane filtration processes
    • S. Sethi M.R. Wiesner Cost modeling and estimation of crossflow membrane filtration processes Environ. Sci. Technol. 17 2000 61-79
    • (2000) Environ. Sci. Technol. , vol.17 , pp. 61-79
    • Sethi, S.1    Wiesner, M.R.2
  • 19
    • 27644510332 scopus 로고    scopus 로고
    • The Dow Chemical, Element Value Analysis, Reverse Osmosis System Analysis
    • (ROSA 6.0), Midland
    • The Dow Chemical, Element Value Analysis, Reverse Osmosis System Analysis (ROSA 6.0), Midland 2004
    • (2004)
  • 20
    • 27644554112 scopus 로고    scopus 로고
    • verbal information Membrane
    • Italia M. Arcari verbal information Membrane 2004
    • (2004)
    • Arcari, M.1
  • 21
    • 27644577233 scopus 로고    scopus 로고
    • The Dow Chemical, FT-Norm, Midland
    • The Dow Chemical, FT-Norm, Midland 2004
    • (2004)


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.