메뉴 건너뛰기




Volumn 15, Issue 4, 2005, Pages 673-686

Aids to insertion: Magnetic imaging, variable stiffness, and overtubes

Author keywords

[No Author keywords available]

Indexed keywords

ENEMA;

EID: 27644550887     PISSN: 10525157     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.giec.2005.08.011     Document Type: Review
Times cited : (17)

References (48)
  • 1
    • 0028784355 scopus 로고
    • Intraoperative measurement of colonic anatomy and attachments with relevance to colonoscopy
    • B.P. Saunders, R.K.S. Phillips, and C.B. Williams Intraoperative measurement of colonic anatomy and attachments with relevance to colonoscopy Br J Surg 82 1995 1491 1493
    • (1995) Br J Surg , vol.82 , pp. 1491-1493
    • Saunders, B.P.1    Phillips, R.K.S.2    Williams, C.B.3
  • 3
    • 84965202311 scopus 로고
    • Lectures on the anatomy of the intestinal canal and peritoneum in man
    • F. Treves Lectures on the anatomy of the intestinal canal and peritoneum in man BMJ 1 1885 415 583
    • (1885) BMJ , vol.1 , pp. 415-583
    • Treves, F.1
  • 4
    • 0004566417 scopus 로고
    • A statistical review of the variations in the anatomic positions of the caecum and the processus vermiformis in the infant
    • G.M. Smith A statistical review of the variations in the anatomic positions of the caecum and the processus vermiformis in the infant Anat Rec 5 1911 549 556
    • (1911) Anat Rec , vol.5 , pp. 549-556
    • Smith, G.M.1
  • 5
    • 0001448752 scopus 로고
    • What makes colonoscopy difficult?
    • B.P. Saunders, F.A. Macrae, and C.B. Williams What makes colonoscopy difficult? [abstract] Gut 1 1993 T179
    • (1993) Gut , vol.1 , pp. 179
    • Saunders, B.P.1    MacRae, F.A.2    Williams, C.B.3
  • 6
    • 0029006005 scopus 로고
    • Can barium enema indicate when colonoscopy will be difficult?
    • B.P. Saunders, S. Halligan, and C. Jobling Can barium enema indicate when colonoscopy will be difficult? Clin Radiol 50 1995 318 321
    • (1995) Clin Radiol , vol.50 , pp. 318-321
    • Saunders, B.P.1    Halligan, S.2    Jobling, C.3
  • 8
    • 0027284521 scopus 로고
    • The frequency of total colonoscopy and terminal ileal intubation in the 1990s
    • J.B. Marshall, and J.S. Barthel The frequency of total colonoscopy and terminal ileal intubation in the 1990s Gastrointest Endosc 39 4 1993 518 520
    • (1993) Gastrointest Endosc , vol.39 , Issue.4 , pp. 518-520
    • Marshall, J.B.1    Barthel, J.S.2
  • 9
    • 0031014334 scopus 로고    scopus 로고
    • Relative sensitivity of colonoscopy and barium enema for detection of colorectal cancer in clinical practice
    • D.K. Rex, E.Y. Rahmani, and J.H. Haseman Relative sensitivity of colonoscopy and barium enema for detection of colorectal cancer in clinical practice Gastroenterology 112 1 1997 17 23
    • (1997) Gastroenterology , vol.112 , Issue.1 , pp. 17-23
    • Rex, D.K.1    Rahmani, E.Y.2    Haseman, J.H.3
  • 10
    • 0000495186 scopus 로고
    • The national ASGE colonoscopy survey: Analysis of colonoscopic practices and yield [abstract]
    • D.A. Gilbert, S.L. Shaneyfelt, and F.E. Silverstein The national ASGE colonoscopy survey: analysis of colonoscopic practices and yield [abstract] Gastrointest Endosc 30 1984 143
    • (1984) Gastrointest Endosc , vol.30 , pp. 143
    • Gilbert, D.A.1    Shaneyfelt, S.L.2    Silverstein, F.E.3
  • 11
    • 0034934805 scopus 로고    scopus 로고
    • The impact of endoscopist's experience and learning curves and interendoscopist variation on colonoscopy completion rates
    • G. Dafnis, F. Granath, and L. Påhlman The impact of endoscopist's experience and learning curves and interendoscopist variation on colonoscopy completion rates Endoscopy 33 6 2001 511 517
    • (2001) Endoscopy , vol.33 , Issue.6 , pp. 511-517
    • Dafnis, G.1    Granath, F.2    Påhlman, L.3
  • 12
    • 0002493144 scopus 로고    scopus 로고
    • Intercollegiate BSG national colonoscopy (IBNC) audit: Methods used to identify the caecum and caecal intubation rate [abstract]
    • C.J.A. Bowles, R.J. Leicester, and E. Swarbrick Intercollegiate BSG national colonoscopy (IBNC) audit: methods used to identify the caecum and caecal intubation rate [abstract] Gut 48 Suppl 1 2001 A10 A11
    • (2001) Gut , vol.48 , Issue.1 SUPPL.
    • Bowles, C.J.A.1    Leicester, R.J.2    Swarbrick, E.3
  • 13
    • 0020057101 scopus 로고
    • A prospective study of diagnostic methods in adenoma follow-up
    • C.B. Williams, F.A. Macrae, and C.I. Bartram A prospective study of diagnostic methods in adenoma follow-up Endoscopy 14 1982 74 78
    • (1982) Endoscopy , vol.14 , pp. 74-78
    • Williams, C.B.1    MacRae, F.A.2    Bartram, C.I.3
  • 14
    • 0029003105 scopus 로고
    • Accuracy of colonoscopy in localisation of colorectal cancer
    • J.H. Hancock, and R.W. Talbot Accuracy of colonoscopy in localisation of colorectal cancer Int J Colorectal Dis 10 1995 140 141
    • (1995) Int J Colorectal Dis , vol.10 , pp. 140-141
    • Hancock, J.H.1    Talbot, R.W.2
  • 15
    • 0015776948 scopus 로고
    • Progress report: Colonoscopy
    • C.B. Williams, and R. Teague Progress report: colonoscopy Gut 14 1973 990 1003
    • (1973) Gut , vol.14 , pp. 990-1003
    • Williams, C.B.1    Teague, R.2
  • 16
    • 0015222177 scopus 로고
    • Colonofiberoscopy
    • W.I. Wolff, and H. Shinya Colonofiberoscopy JAMA 217 11 1971 1509 1512
    • (1971) JAMA , vol.217 , Issue.11 , pp. 1509-1512
    • Wolff, W.I.1    Shinya, H.2
  • 17
    • 0027410418 scopus 로고
    • Non-radiological technique for three-dimensional imaging of endoscopes
    • J.S. Bladen, A.P. Anderson, and G.D. Bell Non-radiological technique for three-dimensional imaging of endoscopes Lancet 341 1993 719 722
    • (1993) Lancet , vol.341 , pp. 719-722
    • Bladen, J.S.1    Anderson, A.P.2    Bell, G.D.3
  • 18
    • 0027477890 scopus 로고
    • Electronic three-dimensional imaging of intestinal endoscopy
    • C.B. Williams, C. Guy, and D. Gillies Electronic three-dimensional imaging of intestinal endoscopy Lancet 341 1993 724 725
    • (1993) Lancet , vol.341 , pp. 724-725
    • Williams, C.B.1    Guy, C.2    Gillies, D.3
  • 19
    • 0033929510 scopus 로고    scopus 로고
    • Magnetic imaging of colonoscopy: An audit of looping, accuracy and ancillary maneuvers
    • S.G. Shah, B.P. Saunders, and J.C. Brooker Magnetic imaging of colonoscopy: an audit of looping, accuracy and ancillary maneuvers Gastrointest Endosc 52 1 2000 1 8
    • (2000) Gastrointest Endosc , vol.52 , Issue.1 , pp. 1-8
    • Shah, S.G.1    Saunders, B.P.2    Brooker, J.C.3
  • 20
    • 0036275852 scopus 로고    scopus 로고
    • Patient pain during colonoscopy: An analysis using real-time magnetic endoscope imaging
    • S.G. Shah, J.C. Brooker, and C. Thapar Patient pain during colonoscopy: an analysis using real-time magnetic endoscope imaging Endoscopy 34 2002 435 440
    • (2002) Endoscopy , vol.34 , pp. 435-440
    • Shah, S.G.1    Brooker, J.C.2    Thapar, C.3
  • 21
    • 0034959903 scopus 로고    scopus 로고
    • Inadequacy of colonoscopy revealed by three-dimensional electromagnetic imaging
    • I.J. Adam, Z. Ali, and A.J. Shorthouse Inadequacy of colonoscopy revealed by three-dimensional electromagnetic imaging Dis Colon Rectum 44 7 2001 978 983
    • (2001) Dis Colon Rectum , vol.44 , Issue.7 , pp. 978-983
    • Adam, I.J.1    Ali, Z.2    Shorthouse, A.J.3
  • 22
    • 0036847888 scopus 로고    scopus 로고
    • Magnetic endoscope imaging: A new technique for localisation of colonic lesions
    • S.G. Shah, H.J. Pearson, and S. Moss Magnetic endoscope imaging: a new technique for localisation of colonic lesions Endoscopy 34 2002 900 904
    • (2002) Endoscopy , vol.34 , pp. 900-904
    • Shah, S.G.1    Pearson, H.J.2    Moss, S.3
  • 23
    • 0029075023 scopus 로고
    • First clinical results with a real time, electronic imager as an aid to colonoscopy
    • B.P. Saunders, G.D. Bell, and C.B. Williams First clinical results with a real time, electronic imager as an aid to colonoscopy Gut 36 6 1995 913 917
    • (1995) Gut , vol.36 , Issue.6 , pp. 913-917
    • Saunders, B.P.1    Bell, G.D.2    Williams, C.B.3
  • 24
    • 0034684444 scopus 로고    scopus 로고
    • Effect of magnetic endoscope imaging on colonoscopy performance: A randomised controlled trial
    • S.G. Shah, J.C. Brooker, and C.B. Williams Effect of magnetic endoscope imaging on colonoscopy performance: a randomised controlled trial Lancet 356 2000 1718 1722
    • (2000) Lancet , vol.356 , pp. 1718-1722
    • Shah, S.G.1    Brooker, J.C.2    Williams, C.B.3
  • 25
    • 0036617888 scopus 로고    scopus 로고
    • Effect of magnetic endoscope imaging on patient tolerance and sedation requirements during colonoscopy: A randomised controlled trial
    • S.G. Shah, J.C. Brooker, and C. Thapar Effect of magnetic endoscope imaging on patient tolerance and sedation requirements during colonoscopy: a randomised controlled trial Gastrointest Endosc 55 2002 832
    • (2002) Gastrointest Endosc , vol.55 , pp. 832
    • Shah, S.G.1    Brooker, J.C.2    Thapar, C.3
  • 26
    • 0038367927 scopus 로고    scopus 로고
    • Effect of real-time magnetic endoscope imaging on the teaching and acquisition of colonoscopy skills: Results from a single trainee
    • S.G. Shah, S. Thomas-Gibson, and M. Lockett Effect of real-time magnetic endoscope imaging on the teaching and acquisition of colonoscopy skills: results from a single trainee Endoscopy 35 2003 421 425
    • (2003) Endoscopy , vol.35 , pp. 421-425
    • Shah, S.G.1    Thomas-Gibson, S.2    Lockett, M.3
  • 27
    • 0036782722 scopus 로고    scopus 로고
    • Use of video and magnetic endoscope imaging for rating competence at colonoscopy: Validation of a measurement tool
    • S.G. Shah, S. Thomas-Gibson, and J.C. Brooker Use of video and magnetic endoscope imaging for rating competence at colonoscopy: validation of a measurement tool Gastrointest Endosc 56 2002 568 573
    • (2002) Gastrointest Endosc , vol.56 , pp. 568-573
    • Shah, S.G.1    Thomas-Gibson, S.2    Brooker, J.C.3
  • 28
    • 0015421895 scopus 로고
    • The technique of colonofiberoscopy
    • Y. Sakai The technique of colonofiberoscopy Dis Colon Rectum 15 1972 403 412
    • (1972) Dis Colon Rectum , vol.15 , pp. 403-412
    • Sakai, Y.1
  • 29
    • 0025976818 scopus 로고
    • Colonoscope damage from internal straightener use
    • T.A. Ruffolo, G.A. Lehman, and D. Rex Colonoscope damage from internal straightener use Gastrointest Endosc 37 1991 107 108
    • (1991) Gastrointest Endosc , vol.37 , pp. 107-108
    • Ruffolo, T.A.1    Lehman, G.A.2    Rex, D.3
  • 30
    • 0000920361 scopus 로고
    • Colonoscopy intubation techniques with fluoroscopy
    • R.H. Hunt J.D. Waye Chapman & Hall London
    • R.H. Hunt Colonoscopy intubation techniques with fluoroscopy R.H. Hunt J.D. Waye Colonoscopy: techniques, clinical practice, and colour atlas 1981 Chapman & Hall London 109 146
    • (1981) Colonoscopy: Techniques, Clinical Practice, and Colour Atlas , pp. 109-146
    • Hunt, R.H.1
  • 31
    • 0036232930 scopus 로고    scopus 로고
    • Novel three-channel and three-slit stiffening tube for total colonoscopy
    • M. Mukai, S. Mukohyama, and H. Nakazaki Novel three-channel and three-slit stiffening tube for total colonoscopy Endoscopy 34 2002 382 384
    • (2002) Endoscopy , vol.34 , pp. 382-384
    • Mukai, M.1    Mukohyama, S.2    Nakazaki, H.3
  • 32
    • 1542724576 scopus 로고    scopus 로고
    • A novel shape-locking guide for prevention of sigmoid looping during colonoscopy
    • G.S. Raju, D.K. Rex, and R.A. Kozarek A novel shape-locking guide for prevention of sigmoid looping during colonoscopy Gastrointest Endosc 59 2004 416 419
    • (2004) Gastrointest Endosc , vol.59 , pp. 416-419
    • Raju, G.S.1    Rex, D.K.2    Kozarek, R.A.3
  • 33
    • 27644592319 scopus 로고
    • A split overtube for easier colonoscopy [abstract]
    • C.B. Williams A split overtube for easier colonoscopy [abstract] Gastrointest Endosc 29 2 1983 188
    • (1983) Gastrointest Endosc , vol.29 , Issue.2 , pp. 188
    • Williams, C.B.1
  • 34
    • 0034074393 scopus 로고    scopus 로고
    • A new variable stiffness colonoscope makes colonoscopy easier: A randomised controlled trial
    • J.C. Brooker, B.P. Saunders, and S.G. Shah A new variable stiffness colonoscope makes colonoscopy easier: a randomised controlled trial Gut 46 2000 801 805
    • (2000) Gut , vol.46 , pp. 801-805
    • Brooker, J.C.1    Saunders, B.P.2    Shah, S.G.3
  • 35
    • 0001867733 scopus 로고    scopus 로고
    • Variable stiffness colonoscope versus standard colonoscope: Results of a European multi-centre randomised study [abstract]
    • T. Ameif, G. Barabara, and M. Bretthauer Variable stiffness colonoscope versus standard colonoscope: results of a European multi-centre randomised study [abstract] Endoscopy 31 Suppl 1 2000 E2
    • (2000) Endoscopy , vol.31 , Issue.1 SUPPL. , pp. 2
    • Ameif, T.1    Barabara, G.2    Bretthauer, M.3
  • 36
    • 0034960504 scopus 로고    scopus 로고
    • Clinical results and development of variable-stiffness video colonoscopes
    • T. Odori, H. Goto, and T. Arisawa Clinical results and development of variable-stiffness video colonoscopes Endoscopy 33 1 2001 65 69
    • (2001) Endoscopy , vol.33 , Issue.1 , pp. 65-69
    • Odori, T.1    Goto, H.2    Arisawa, T.3
  • 37
    • 0036895952 scopus 로고    scopus 로고
    • Variable stiffness colonoscopes are associated with less pain during colonoscopy in unsedated patients
    • I. Yoshikawa, H. Honda, and K. Nagata Variable stiffness colonoscopes are associated with less pain during colonoscopy in unsedated patients Am J Gastroenterol 97 2002 3052 3055
    • (2002) Am J Gastroenterol , vol.97 , pp. 3052-3055
    • Yoshikawa, I.1    Honda, H.2    Nagata, K.3
  • 38
    • 0035347248 scopus 로고    scopus 로고
    • Clinical application of a new colonoscope with variable insertion tube rigidity: A pilot study
    • D. Sorbi, C.D. Schleck, and A.R. Zinsmeister Clinical application of a new colonoscope with variable insertion tube rigidity: a pilot study Gastrointest Endosc 53 2001 638 642
    • (2001) Gastrointest Endosc , vol.53 , pp. 638-642
    • Sorbi, D.1    Schleck, C.D.2    Zinsmeister, A.R.3
  • 39
    • 0034948809 scopus 로고    scopus 로고
    • Effect of variable stiffness colonoscopes on cecal intubation times for routine colonoscopy by an experienced examiner in sedated patients
    • D.K. Rex Effect of variable stiffness colonoscopes on cecal intubation times for routine colonoscopy by an experienced examiner in sedated patients Endoscopy 33 2001 60 64
    • (2001) Endoscopy , vol.33 , pp. 60-64
    • Rex, D.K.1
  • 40
    • 0000083481 scopus 로고    scopus 로고
    • Variable rigidity colonoscopes: A randomized controlled study [abstract]
    • C.J. Gostout, D. Sorbi, and M.A. Knipschield Variable rigidity colonoscopes: a randomized controlled study [abstract] Gastrointest Endosc 53 2001 AB179
    • (2001) Gastrointest Endosc , vol.53 , pp. 179
    • Gostout, C.J.1    Sorbi, D.2    Knipschield, M.A.3
  • 41
    • 23044505030 scopus 로고    scopus 로고
    • A comparative trial of variable stiffness colonoscopes [abstract]
    • D.A. Howell, P.M. Ku, and D.J. Desilets A comparative trial of variable stiffness colonoscopes [abstract] Gastrointest Endosc 55 2001 AB58
    • (2001) Gastrointest Endosc , vol.55 , pp. 58
    • Howell, D.A.1    Ku, P.M.2    Desilets, D.J.3
  • 42
    • 0036480120 scopus 로고    scopus 로고
    • A randomized controlled trial in a training institution comparing a pediatric variable stiffness colonoscope, a pediatric colonoscope, and an adult colonoscope
    • D.A. Shumaker, A. Zaman, and R.M. Katon A randomized controlled trial in a training institution comparing a pediatric variable stiffness colonoscope, a pediatric colonoscope, and an adult colonoscope Gastrointest Endosc 55 2002 172 179
    • (2002) Gastrointest Endosc , vol.55 , pp. 172-179
    • Shumaker, D.A.1    Zaman, A.2    Katon, R.M.3
  • 43
    • 0036353572 scopus 로고    scopus 로고
    • Use of a variable-stiffness colonoscope allows completion of colonoscopy after failure with the standard adult colonoscope
    • D.A. Shumaker, A. Zaman, and R.M. Katon Use of a variable-stiffness colonoscope allows completion of colonoscopy after failure with the standard adult colonoscope Endoscopy 34 2002 711 714
    • (2002) Endoscopy , vol.34 , pp. 711-714
    • Shumaker, D.A.1    Zaman, A.2    Katon, R.M.3
  • 44
    • 0242541227 scopus 로고    scopus 로고
    • A prospective trial of variable stiffness pediatric vs. standard instrument colonoscopy
    • A.J. Kaffes, A. Mishra, and S.L. Ding A prospective trial of variable stiffness pediatric vs. standard instrument colonoscopy Gastrointest Endosc 58 2003 685 689
    • (2003) Gastrointest Endosc , vol.58 , pp. 685-689
    • Kaffes, A.J.1    Mishra, A.2    Ding, S.L.3
  • 45
    • 7044233586 scopus 로고    scopus 로고
    • Usefulness of a small-caliber, variable-stiffness colonoscope as a backup in patients with difficult or incomplete colonoscopy
    • A. Horiuchi, Y. Nakayama, and M. Kajiyama Usefulness of a small-caliber, variable-stiffness colonoscope as a backup in patients with difficult or incomplete colonoscopy Am J Gastroenterol 99 2004 1936 1940
    • (2004) Am J Gastroenterol , vol.99 , pp. 1936-1940
    • Horiuchi, A.1    Nakayama, Y.2    Kajiyama, M.3
  • 46
    • 0036673091 scopus 로고    scopus 로고
    • The variable stiffness colonoscope: Assessment of efficacy by magnetic endoscope imaging
    • S.G. Shah, J.C. Brooker, and C.B. Williams The variable stiffness colonoscope: assessment of efficacy by magnetic endoscope imaging Gastrointest Endosc 56 2002 196 201
    • (2002) Gastrointest Endosc , vol.56 , pp. 196-201
    • Shah, S.G.1    Brooker, J.C.2    Williams, C.B.3
  • 47
    • 4243282652 scopus 로고    scopus 로고
    • A randomized, controlled trial comparing the efficacy of three different techniques in the performance of variable-stiffness colonoscopy [abstract]
    • A. Kaynard, A. Zaman, and R.M. Katon A randomized, controlled trial comparing the efficacy of three different techniques in the performance of variable-stiffness colonoscopy [abstract] Gastrointest Endosc 55 2002 AB125
    • (2002) Gastrointest Endosc , vol.55 , pp. 125
    • Kaynard, A.1    Zaman, A.2    Katon, R.M.3
  • 48
    • 0032855624 scopus 로고    scopus 로고
    • Colonoscopy aided by magnetic 3D imaging: Assessing the routine use of a stiffening sigmoid overtube to speed up the procedure
    • G.D. Bell, R.S. Rowland, and M. Rutter Colonoscopy aided by magnetic 3D imaging: assessing the routine use of a stiffening sigmoid overtube to speed up the procedure Med Biol Eng Comput 37 1999 605 611
    • (1999) Med Biol Eng Comput , vol.37 , pp. 605-611
    • Bell, G.D.1    Rowland, R.S.2    Rutter, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.