메뉴 건너뛰기




Volumn 64, Issue 1, 2006, Pages 85-92

Development of a computer code using the EGS4 Monte Carlo simulation system to evaluate the response of a NaI(Tl) detector to photons with energies below 300 keV

Author keywords

EGS4; Monte Carlo simulation; NaI(Tl) detector; X rays

Indexed keywords

COMPUTER SIMULATION; CRYSTALLINE MATERIALS; GAMMA RAYS; MONTE CARLO METHODS; PARTICLE DETECTORS; PHOTONS; X RAYS;

EID: 27644498137     PISSN: 09698043     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.apradiso.2004.12.013     Document Type: Article
Times cited : (5)

References (18)
  • 1
    • 0344758344 scopus 로고    scopus 로고
    • EGS4 Monte Carlo simulation of a 90°geometry polarized X-ray fluorescence system
    • F.H.H. Al-Ghorabie EGS4 Monte Carlo simulation of a 90°geometry polarized X-ray fluorescence system Radiat. Phys. Chem. 55 1999 377 384
    • (1999) Radiat. Phys. Chem. , vol.55 , pp. 377-384
    • Al-Ghorabie, F.H.H.1
  • 2
    • 0035150394 scopus 로고    scopus 로고
    • A comparison between EGS4 and MCNP computer modeling of an in vivo X-ray fluorescence system
    • F.H.H. Al-Ghorabie, S.S.A. Natto, and S.H.A. Al-Lyhiani A comparison between EGS4 and MCNP computer modeling of an in vivo X-ray fluorescence system Comput. Biol. Med. 31 2001 73 83
    • (2001) Comput. Biol. Med. , vol.31 , pp. 73-83
    • Al-Ghorabie, F.H.H.1    Natto, S.S.A.2    Al-Lyhiani, S.H.A.3
  • 3
    • 0003658847 scopus 로고
    • The EGS4 code system: Computer programs for the Monte Carlo simulation of electromagnetic cascade showers
    • Ford, R.L., Nelson, W.R., 1978. The EGS4 code system: computer programs for the Monte Carlo simulation of electromagnetic cascade showers. Stanford Linear Accelerator Centre Report SLAC-210.
    • (1978) Stanford Linear Accelerator Centre Report SLAC-210
    • Ford, R.L.1    Nelson, W.R.2
  • 4
    • 0042637834 scopus 로고
    • Monte Carlo calculation of the energy loss spectra for gamma rays in cylindrical NaI(Tl) crystals
    • M. Giannini, P.R. Oliva, and M.C. Ramorino Monte Carlo calculation of the energy loss spectra for gamma rays in cylindrical NaI(Tl) crystals Nucl. Instrum. Meth. Phys. Res. A 81 1970 104 108
    • (1970) Nucl. Instrum. Meth. Phys. Res. a , vol.81 , pp. 104-108
    • Giannini, M.1    Oliva, P.R.2    Ramorino, M.C.3
  • 6
    • 0033002725 scopus 로고    scopus 로고
    • Comparisons between MCNP, EGS4 and experiment for clinical electron beams
    • R. Jeraj, P.J. Keall, and P.M. Ostwald Comparisons between MCNP, EGS4 and experiment for clinical electron beams Phys. Med. Biol. 44 1999 705 717
    • (1999) Phys. Med. Biol. , vol.44 , pp. 705-717
    • Jeraj, R.1    Keall, P.J.2    Ostwald, P.M.3
  • 9
    • 0010592840 scopus 로고
    • Adaptation of the EGS4 Monte Carlo code for the design of a polarized source for X-ray fluorescence analysis of platinum and other heavy metals in vivo
    • P.K. Predecki Plenum New York*et al.
    • D.G. Lewis, A. Kilic, and C.A. Ogg Adaptation of the EGS4 Monte Carlo code for the design of a polarized source for X-ray fluorescence analysis of platinum and other heavy metals in vivo P.K. Predecki Advances in X-ray Analysis vol. 38 1995 Plenum New York 579 583
    • (1995) Advances in X-ray Analysis , vol.38 , pp. 579-583
    • Lewis, D.G.1    Kilic, A.2    Ogg, C.A.3
  • 10
    • 0003030233 scopus 로고
    • Structure and operation of the EGS4 code system
    • T.M. Jenkins W.R. Nelson A. Rindi Plenum New York
    • W.R. Nelson, and D.W. Rogers Structure and operation of the EGS4 code system T.M. Jenkins W.R. Nelson A. Rindi Monte Carlo Transport of Electrons and Photons 1988 Plenum New York 287 310
    • (1988) Monte Carlo Transport of Electrons and Photons , pp. 287-310
    • Nelson, W.R.1    Rogers, D.W.2
  • 12
    • 0032793876 scopus 로고    scopus 로고
    • Comparison of EGS4 and MCNP4b Monte Carlo codes for generation of photon phase space distributions for a Varian 2100C
    • J.V. Siebers, P.J. Keall, B. Libby, and R. Mohan Comparison of EGS4 and MCNP4b Monte Carlo codes for generation of photon phase space distributions for a Varian 2100C Phys. Med. Biol. 44 1999 3009 3026
    • (1999) Phys. Med. Biol. , vol.44 , pp. 3009-3026
    • Siebers, J.V.1    Keall, P.J.2    Libby, B.3    Mohan, R.4
  • 16
    • 27644469691 scopus 로고
    • Monte Carlo calculation of photofractions and intrinsic efficiencies of cylindrical NaI(Tl) scintillation detectors
    • C. Weitkamp Monte Carlo calculation of photofractions and intrinsic efficiencies of cylindrical NaI(Tl) scintillation detectors Nucl. Instrum. Meth. Phys. Res. A 23 1963 13 18
    • (1963) Nucl. Instrum. Meth. Phys. Res. a , vol.23 , pp. 13-18
    • Weitkamp, C.1
  • 17
    • 0032916211 scopus 로고    scopus 로고
    • Relevance of accurate Monte Carlo modeling in nuclear medical imaging
    • H. Zaidi Relevance of accurate Monte Carlo modeling in nuclear medical imaging Med. Phys. 26 1999 574 608
    • (1999) Med. Phys. , vol.26 , pp. 574-608
    • Zaidi, H.1
  • 18
    • 0345140095 scopus 로고
    • Calculation of the pulse-height response of NaI(Tl) scintillation counters
    • C.D. Zerby, and H.S. Moran Calculation of the pulse-height response of NaI(Tl) scintillation counters Nucl. Instrum. Meth. Phys. Res. A 14 1962 115 124
    • (1962) Nucl. Instrum. Meth. Phys. Res. a , vol.14 , pp. 115-124
    • Zerby, C.D.1    Moran, H.S.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.