메뉴 건너뛰기




Volumn 66, Issue 3, 2005, Pages 397-399

Percutaneous atrial septal defect closure: Pushing the envelope but pushing it gently. Editorial comment

Author keywords

[No Author keywords available]

Indexed keywords

BALLOON CATHETER; BALLOON OCCLUSION; CONTRAST ENHANCEMENT; DEVICE; HEART ATRIUM SEPTUM DEFECT; HEART CATHETERIZATION; HUMAN; NOTE; TECHNIQUE; TRANSESOPHAGEAL ECHOCARDIOGRAPHY;

EID: 27644485634     PISSN: 15221946     EISSN: None     Source Type: Journal    
DOI: 10.1002/ccd.20509     Document Type: Note
Times cited : (4)

References (6)
  • 1
    • 0017300623 scopus 로고
    • Secundum atrial septal defect: Nonoperative closure during cardiac catheterization
    • King TD, Thompson SL, Steiner C, Mills NL. Secundum atrial septal defect: nonoperative closure during cardiac catheterization. JAMA 1976;235:2506-2509.
    • (1976) JAMA , vol.235 , pp. 2506-2509
    • King, T.D.1    Thompson, S.L.2    Steiner, C.3    Mills, N.L.4
  • 2
    • 0031467061 scopus 로고    scopus 로고
    • Transcatheter closure of secundum atrial septal defects using the new self-centering amplatzer septal occluder: Initial human experience
    • Masura J, Gavora P, Formanek A, Hijazi ZM. Transcatheter closure of secundum atrial septal defects using the new self-centering amplatzer septal occluder: initial human experience. Cathet Cardiovasc Diagn 1997;42:388-393.
    • (1997) Cathet Cardiovasc Diagn , vol.42 , pp. 388-393
    • Masura, J.1    Gavora, P.2    Formanek, A.3    Hijazi, Z.M.4
  • 3
    • 0033768488 scopus 로고    scopus 로고
    • Transcatheter retrieval and repositioning of an Amplatzer device embolized into the left atrium
    • Peuster M, Boekenkamp R, Kaulitz R, Fink C, Hausdorf G. Transcatheter retrieval and repositioning of an Amplatzer device embolized into the left atrium. Catheter Cardiovasc Interv 2000;51:297-300.
    • (2000) Catheter Cardiovasc Interv , vol.51 , pp. 297-300
    • Peuster, M.1    Boekenkamp, R.2    Kaulitz, R.3    Fink, C.4    Hausdorf, G.5
  • 4
    • 0037624939 scopus 로고    scopus 로고
    • Successful repositioning of an Amplatzer duct occluder immediately after inadvertent embolization in the descending aorta
    • Pfammatter JP, Meier B. Successful repositioning of an Amplatzer duct occluder immediately after inadvertent embolization in the descending aorta. Catheter Cardiovasc Interv 2003;59:83-85.
    • (2003) Catheter Cardiovasc Interv , vol.59 , pp. 83-85
    • Pfammatter, J.P.1    Meier, B.2
  • 5
    • 1842531953 scopus 로고    scopus 로고
    • Embolization and retrieval of the Amplatzer septal occluder
    • Levi DS, Moore JW. Embolization and retrieval of the Amplatzer septal occluder. Catheter Cardiovasc Interv 2004;61:543-547.
    • (2004) Catheter Cardiovasc Interv , vol.61 , pp. 543-547
    • Levi, D.S.1    Moore, J.W.2
  • 6
    • 9644275542 scopus 로고    scopus 로고
    • Erosion of Amplatzer septal occluder device after closure of secundum atrial septal defects: Review of registry of complications and recommendations to minimize future risk
    • Amin Z, Hijazi ZM, Bass JL, Cheatham JP, Hellenbrand WE, Kleinman CS. Erosion of Amplatzer septal occluder device after closure of secundum atrial septal defects: review of registry of complications and recommendations to minimize future risk. Catheter Cardiovasc Interv 2004;63:496-502.
    • (2004) Catheter Cardiovasc Interv , vol.63 , pp. 496-502
    • Amin, Z.1    Hijazi, Z.M.2    Bass, J.L.3    Cheatham, J.P.4    Hellenbrand, W.E.5    Kleinman, C.S.6