메뉴 건너뛰기




Volumn 96, Issue 10, 2005, Pages 1456-1459

Comparative accuracy of color M-mode and tissue doppler echocardiography in the emergency diagnosis of congestive heart failure in chronic hypertensive patients with normal left ventricular ejection fraction

Author keywords

[No Author keywords available]

Indexed keywords

ANTIHYPERTENSIVE AGENT; DIURETIC AGENT; NITRATE;

EID: 27644442001     PISSN: 00029149     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.amjcard.2005.07.051     Document Type: Article
Times cited : (19)

References (20)
  • 1
    • 0032192138 scopus 로고    scopus 로고
    • New Doppler echocardiographic applications for the study of diastolic function
    • M.J. Garcia, J.D. Thomas, A.L. Klein New Doppler echocardiographic applications for the study of diastolic function J Am Coll Cardiol 32 1998 865 875
    • (1998) J Am Coll Cardiol , vol.32 , pp. 865-875
    • Garcia, M.J.1    Thomas, J.D.2    Klein, A.L.3
  • 2
    • 0037443576 scopus 로고    scopus 로고
    • Impact of left ventricular ejection fraction on estimation of left ventricular filling pressures using tissue Doppler and flow propagation velocity
    • C. Rivas-Gotz, M. Manolios, V. Thohan, S.F. Nagueh Impact of left ventricular ejection fraction on estimation of left ventricular filling pressures using tissue Doppler and flow propagation velocity Am J Cardiol 91 2003 780 784
    • (2003) Am J Cardiol , vol.91 , pp. 780-784
    • Rivas-Gotz, C.1    Manolios, M.2    Thohan, V.3    Nagueh, S.F.4
  • 3
    • 15244349240 scopus 로고    scopus 로고
    • Usefulness of tissue Doppler imaging for estimation of left ventricular filling pressures in patients with systolic and diastolic heart failure
    • C. Bruch, M. Grude, J. Muller, G. Breithardt, T. Wichter Usefulness of tissue Doppler imaging for estimation of left ventricular filling pressures in patients with systolic and diastolic heart failure Am J Cardiol 95 2005 892 895
    • (2005) Am J Cardiol , vol.95 , pp. 892-895
    • Bruch, C.1    Grude, M.2    Muller, J.3    Breithardt, G.4    Wichter, T.5
  • 4
    • 16844381602 scopus 로고    scopus 로고
    • Comparison of tissue Doppler and propagation velocity to invasive measures for measuring left ventricular filling pressures
    • J.L. Dorosz, K.G. Lehmann, J.R. Stratton Comparison of tissue Doppler and propagation velocity to invasive measures for measuring left ventricular filling pressures Am J Cardiol 95 2005 1017 1020
    • (2005) Am J Cardiol , vol.95 , pp. 1017-1020
    • Dorosz, J.L.1    Lehmann, K.G.2    Stratton, J.R.3
  • 6
    • 1942468005 scopus 로고    scopus 로고
    • Comparative accuracy of B-type natriuretic peptide and tissue Doppler echocardiography in the diagnosis of congestive heart failure
    • H. Dokainish, W.A. Zoghbi, N.M. Lakkis, M.A. Quinones, S.F. Nagueh Comparative accuracy of B-type natriuretic peptide and tissue Doppler echocardiography in the diagnosis of congestive heart failure Am J Cardiol 93 2004 1130 1135
    • (2004) Am J Cardiol , vol.93 , pp. 1130-1135
    • Dokainish, H.1    Zoghbi, W.A.2    Lakkis, N.M.3    Quinones, M.A.4    Nagueh, S.F.5
  • 7
    • 27644577750 scopus 로고    scopus 로고
    • Accuracy of tissue Doppler echocardiography in the emergency diagnosis of decompensated heart failure with preserved left ventricular systolic function. Comparison with B-Type natriuretic peptide measurement
    • S. Arques, E. Roux, P. Sbragia, P. Ambrosi, L. Taieb, B. Pieri, R. Gelisse, R. Luccioni Accuracy of tissue Doppler echocardiography in the emergency diagnosis of decompensated heart failure with preserved left ventricular systolic function. Comparison with B-Type natriuretic peptide measurement Echocardiography 22 2005 657 664
    • (2005) Echocardiography , vol.22 , pp. 657-664
    • Arques, S.1    Roux, E.2    Sbragia, P.3    Ambrosi, P.4    Taieb, L.5    Pieri, B.6    Gelisse, R.7    Luccioni, R.8
  • 8
    • 16244402639 scopus 로고    scopus 로고
    • Left heart failure with a normal ejection fraction: Identification of different pathophysiologic mechanisms
    • M.S. Maurer, D.L. King, L. El-Khoury Rumbarger, M. Packer, D. Burkhoff Left heart failure with a normal ejection fraction identification of different pathophysiologic mechanisms J Card Fail 11 2005 177 187
    • (2005) J Card Fail , vol.11 , pp. 177-187
    • Maurer, M.S.1    King, D.L.2    El-Khoury Rumbarger, L.3    Packer, M.4    Burkhoff, D.5
  • 9
    • 0034595310 scopus 로고    scopus 로고
    • Defining diastolic heart failure: A call for standardized diagnostic criteria
    • R.S. Vasan, D. Levy Defining diastolic heart failure a call for standardized diagnostic criteria Circulation 101 2000 2118 2121
    • (2000) Circulation , vol.101 , pp. 2118-2121
    • Vasan, R.S.1    Levy, D.2
  • 11
    • 0031019476 scopus 로고    scopus 로고
    • An index of early left ventricular filling that combined with pulsed Doppler peak e velocity may estimate capillary wedge pressure
    • M.J. Garcia, M.A. Ares, C. Asher, L. Rodriguez, P. Vandervoort, J.D. Thomas An index of early left ventricular filling that combined with pulsed Doppler peak E velocity may estimate capillary wedge pressure J Am Coll Cardiol 29 1997 448 454
    • (1997) J Am Coll Cardiol , vol.29 , pp. 448-454
    • Garcia, M.J.1    Ares, M.A.2    Asher, C.3    Rodriguez, L.4    Vandervoort, P.5    Thomas, J.D.6
  • 12
    • 0030698732 scopus 로고    scopus 로고
    • Doppler tissue imaging: A noninvasive technique for evaluation of left ventricular relaxation and estimation of filling pressures
    • S.F. Nagueh, K.J. Middleton, H.A. Kopelen, W.A. Zoghbi, M.A. Quinones Doppler tissue imaging a noninvasive technique for evaluation of left ventricular relaxation and estimation of filling pressures J Am Coll Cardiol 30 1997 1527 1533
    • (1997) J Am Coll Cardiol , vol.30 , pp. 1527-1533
    • Nagueh, S.F.1    Middleton, K.J.2    Kopelen, H.A.3    Zoghbi, W.A.4    Quinones, M.A.5
  • 13
    • 0031543101 scopus 로고    scopus 로고
    • Determination of left ventricular filling pressure by Doppler echocardiography in patients with coronary artery disease: Critical role of left ventricular systolic function
    • K. Yamamoto, R.A. Nishimura, H.P. Chaliki, C.P. Appleton, D.R. Holmes Jr, M.M. Redfield Determination of left ventricular filling pressure by Doppler echocardiography in patients with coronary artery disease critical role of left ventricular systolic function J Am Coll Cardiol 30 1997 1819 1826
    • (1997) J Am Coll Cardiol , vol.30 , pp. 1819-1826
    • Yamamoto, K.1    Nishimura, R.A.2    Chaliki, H.P.3    Appleton, C.P.4    Holmes Jr., D.R.5    Redfield, M.M.6
  • 14
    • 1842738499 scopus 로고    scopus 로고
    • Potentials and limitations of color M-Mode and tissue Doppler indexes in identifying pseudonormal mitral filling pattern in patients with acute symptoms of heart failure and preserved left ventricular systolic function
    • S. Arques, P. Ambrosi, E. Roux, G. Habib Potentials and limitations of color M-Mode and tissue Doppler indexes in identifying pseudonormal mitral filling pattern in patients with acute symptoms of heart failure and preserved left ventricular systolic function Am J Cardiol 93 2004 1057 1060
    • (2004) Am J Cardiol , vol.93 , pp. 1057-1060
    • Arques, S.1    Ambrosi, P.2    Roux, E.3    Habib, G.4
  • 17
    • 5044226625 scopus 로고    scopus 로고
    • Which echocardiographic Doppler left ventricular diastolic function measurements are most feasible in the clinical echocardiographic laboratory?
    • S. Khan, R.L. Bess, H.S. Rosman, C.K. Nordstrom, G.I. Cohen, J.M. Gardin Which echocardiographic Doppler left ventricular diastolic function measurements are most feasible in the clinical echocardiographic laboratory? Am J Cardiol 94 2004 1099 1101
    • (2004) Am J Cardiol , vol.94 , pp. 1099-1101
    • Khan, S.1    Bess, R.L.2    Rosman, H.S.3    Nordstrom, C.K.4    Cohen, G.I.5    Gardin, J.M.6
  • 18
    • 18944362701 scopus 로고    scopus 로고
    • Abnormal septal motion affects early diastolic velocities at the septal and lateral mitral annulus, and impacts on estimation of the pulmonary capillary wedge pressure
    • K.A. D'Souza, D.J. Mooney, A.E. Russell, A.I. MacIsaac, P.E. Aylward, D.L. Prior Abnormal septal motion affects early diastolic velocities at the septal and lateral mitral annulus, and impacts on estimation of the pulmonary capillary wedge pressure J Am Soc Echocardiogr 18 2005 445 453
    • (2005) J Am Soc Echocardiogr , vol.18 , pp. 445-453
    • D'Souza, K.A.1    Mooney, D.J.2    Russell, A.E.3    MacIsaac, A.I.4    Aylward, P.E.5    Prior, D.L.6
  • 19
    • 16844382720 scopus 로고    scopus 로고
    • Effects of age, gender, and left ventricular mass on septal mitral annulus velocity (E′) and the ratio of transmitral early peak velocity to E′ (E/E′)
    • J. De Sutter, J. De Backer, N. Van de Veire, A. Velghe, M. De Buyzere, T.C. Gillebert Effects of age, gender, and left ventricular mass on septal mitral annulus velocity (E′) and the ratio of transmitral early peak velocity to E′ (E/E′) Am J Cardiol 95 2005 1020 1023
    • (2005) Am J Cardiol , vol.95 , pp. 1020-1023
    • De Sutter, J.1    De Backer, J.2    Van De Veire, N.3    Velghe, A.4    De Buyzere, M.5    Gillebert, T.C.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.