메뉴 건너뛰기




Volumn 25, Issue 6, 2005, Pages 798-803

Biomechanics of olive wire positioning and tensioning characteristics

Author keywords

External fixation; Olive wires

Indexed keywords

ARTICLE; BIOMECHANICS; BODY POSITION; COMPOSITE MATERIAL; COMPRESSION; DATA ANALYSIS; FRACTURE EXTERNAL FIXATION; HARDNESS; HUMAN; HUMAN TISSUE; KINEMATICS; MEDICAL DECISION MAKING; OSTEOSYNTHESIS; PRIORITY JOURNAL; RIGIDITY; TORSION; WIRE FIXATION;

EID: 27544476050     PISSN: 02716798     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.bpo.0000184646.03981.ec     Document Type: Article
Times cited : (13)

References (33)
  • 2
    • 0036523513 scopus 로고    scopus 로고
    • Basic frame construction: Building fixation block and designing working length mechanism
    • Hutson JJ Jr. Basic frame construction: building fixation block and designing working length mechanism. Tech Orthop. 2002;17:26-33.
    • (2002) Tech Orthop , vol.17 , pp. 26-33
    • Hutson Jr., J.J.1
  • 3
    • 0001889934 scopus 로고
    • The treatment of fractures: Theoretical considerations, experimental studies and clinical application of the apparatus
    • Ilizarov GA, Green SA, eds. Berlin: Springer-Verlag
    • Ilizarov GA. The treatment of fractures: theoretical considerations, experimental studies and clinical application of the apparatus. In: Ilizarov GA, Green SA, eds. Transosseous Osteosynthesis: Theoretical and Clinical Aspects of the Regeneration and Growth of Tissue. Berlin: Springer-Verlag, 1992:369-452.
    • (1992) Transosseous Osteosynthesis: Theoretical and Clinical Aspects of the Regeneration and Growth of Tissue , pp. 369-452
    • Ilizarov, G.A.1
  • 4
    • 27544442033 scopus 로고    scopus 로고
    • The effect of transfixion wires positioning within the bone on the stiffness of proximal tibia external fixation: A biomechanical study
    • Antoci V, Voor MJ, Antoci V Jr, et al. The effect of transfixion wires positioning within the bone on the stiffness of proximal tibia external fixation: a biomechanical study. J Orthop Trauma. 2004;18:51.
    • (2004) J Orthop Trauma , vol.18 , pp. 51
    • Antoci, V.1    Voor, M.J.2    Antoci Jr., V.3
  • 5
    • 16644380643 scopus 로고    scopus 로고
    • Biomechanics of external fixation of distal tibial extra-articular fractures: Is spanning the ankle with a foot plate desirable?
    • Antoci V, Voor MJ, Seligson D, et al. Biomechanics of external fixation of distal tibial extra-articular fractures: is spanning the ankle with a foot plate desirable? J Orthop Trauma. 2004;18:665-673.
    • (2004) J Orthop Trauma , vol.18 , pp. 665-673
    • Antoci, V.1    Voor, M.J.2    Seligson, D.3
  • 6
    • 0034056297 scopus 로고    scopus 로고
    • The Ilizarov fixator for pediatric and adolescent supracondylar fracture variants
    • Gugenheim JJ Jr. The Ilizarov fixator for pediatric and adolescent supracondylar fracture variants. J Pediatr Orthop. 2000;20:177-182.
    • (2000) J Pediatr Orthop , vol.20 , pp. 177-182
    • Gugenheim Jr., J.J.1
  • 7
    • 12344333524 scopus 로고    scopus 로고
    • The effect of wire plane tilt and olive wires on proximal tibia fragment stability and fracture site motion
    • Voor MJ, Antoci V, Antoci V Jr, et al. The effect of wire plane tilt and olive wires on proximal tibia fragment stability and fracture site motion. J Biomech. 2005;38:537-541.
    • (2005) J Biomech , vol.38 , pp. 537-541
    • Voor, M.J.1    Antoci, V.2    Antoci Jr., V.3
  • 8
    • 27544442033 scopus 로고    scopus 로고
    • Ankle-spanning external fixation of distal tibia periarticular fractures
    • Antoci V Jr. Roberts CS, Antoci V, et al. Ankle-spanning external fixation of distal tibia periarticular fractures. J Orthop Trauma. 2004;18:51.
    • (2004) J Orthop Trauma , vol.18 , pp. 51
    • Antoci Jr., V.1    Roberts, C.S.2    Antoci, V.3
  • 9
    • 0032132489 scopus 로고    scopus 로고
    • Use of modified Ilizarov olive wires as pushing wires
    • Atkins RM, Sudhakar JE, Porteous AJ. Use of modified Ilizarov olive wires as pushing wires. J Orthop Trauma. 1998;12:436-438.
    • (1998) J Orthop Trauma , vol.12 , pp. 436-438
    • Atkins, R.M.1    Sudhakar, J.E.2    Porteous, A.J.3
  • 11
    • 0036196784 scopus 로고    scopus 로고
    • Hybrid external fixation for tibial plateau fractures. Clinical and biomechanical correlation
    • Watson JT, Ripple S, Hoshaw SJ, et al. Hybrid external fixation for tibial plateau fractures. Clinical and biomechanical correlation. Orthop Clin North Am. 2002;33:199-209.
    • (2002) Orthop Clin North Am , vol.33 , pp. 199-209
    • Watson, J.T.1    Ripple, S.2    Hoshaw, S.J.3
  • 12
    • 0026674037 scopus 로고
    • Biomechanics of the Ilizarov fixator for fracture fixation
    • Calhoun JH, Li F, Ledbetter BR, et al. Biomechanics of the Ilizarov fixator for fracture fixation. Clin Orthop. 1992;280:15-22.
    • (1992) Clin Orthop , vol.280 , pp. 15-22
    • Calhoun, J.H.1    Li, F.2    Ledbetter, B.R.3
  • 13
    • 0024516018 scopus 로고
    • A biomechanical analysis of the Ilizarov external fixator
    • Fleming B, Paley D, Kristiansen T, et al. A biomechanical analysis of the Ilizarov external fixator. Clin Orthop. 1989;241:95-105.
    • (1989) Clin Orthop , vol.241 , pp. 95-105
    • Fleming, B.1    Paley, D.2    Kristiansen, T.3
  • 14
    • 0026719736 scopus 로고
    • The effect of wire configuration on the stability of the Ilizarov external fixator
    • Orbay GL, Frankel VH, Kummer FJ. The effect of wire configuration on the stability of the Ilizarov external fixator. Clin Orthop. 1992;279:299-302.
    • (1992) Clin Orthop , vol.279 , pp. 299-302
    • Orbay, G.L.1    Frankel, V.H.2    Kummer, F.J.3
  • 15
    • 16244385009 scopus 로고    scopus 로고
    • The effect of transfixion wire number and spacing between two levels of fixation on the stiffness of proximal tibial external fixation
    • Antoci V, Roberts CS, Antoci V Jr, et al. The effect of transfixion wire number and spacing between two levels of fixation on the stiffness of proximal tibial external fixation. J Orthop Trauma. 2005;19:180-186.
    • (2005) J Orthop Trauma , vol.19 , pp. 180-186
    • Antoci, V.1    Roberts, C.S.2    Antoci Jr., V.3
  • 16
    • 1642368932 scopus 로고    scopus 로고
    • The stable functional osteosynthesis with the external fixator in the treatment of fractures, dislocations, and their consequences
    • Antoci V, Betisor V. The stable functional osteosynthesis with the external fixator in the treatment of fractures, dislocations, and their consequences. J Orthop Traumat Romania. 1996;4:177-185.
    • (1996) J Orthop Traumat Romania , vol.4 , pp. 177-185
    • Antoci, V.1    Betisor, V.2
  • 17
    • 0036523594 scopus 로고    scopus 로고
    • Practical biomechanics for the application of Ilizarov fixators to fractures of the tibia
    • Hutson JJ Jr. Practical biomechanics for the application of Ilizarov fixators to fractures of the tibia. Tech Orthop. 2002;17:15-25.
    • (2002) Tech Orthop , vol.17 , pp. 15-25
    • Hutson Jr., J.J.1
  • 18
    • 0025610710 scopus 로고
    • Techniques of fracture reduction: The llizarov method
    • Schwartsman V, Schwartsman R. Techniques of fracture reduction: the llizarov method. Tech Orthop. 1990;5:53-59.
    • (1990) Tech Orthop , vol.5 , pp. 53-59
    • Schwartsman, V.1    Schwartsman, R.2
  • 20
    • 0037305233 scopus 로고    scopus 로고
    • Tibial fractures treated with circular fixation: Does the use of olive wires at the fracture site improve healing?
    • Metcalfe AJ, Branfoot T, Shelbrooke K, et al. Tibial fractures treated with circular fixation: does the use of olive wires at the fracture site improve healing? Injury. 2003;34:145-149.
    • (2003) Injury , vol.34 , pp. 145-149
    • Metcalfe, A.J.1    Branfoot, T.2    Shelbrooke, K.3
  • 21
    • 0025668569 scopus 로고
    • Components of the llizarov system
    • Green SA. Components of the llizarov system. Tech Orthop. 1990;5:1-11.
    • (1990) Tech Orthop , vol.5 , pp. 1-11
    • Green, S.A.1
  • 22
    • 1642393215 scopus 로고    scopus 로고
    • The accuracy of fine tensioners. A comparison of five tensioners used in hybrid and ring external fixation
    • Roberts CS, Antoci V, Antoci V Jr, et al. The accuracy of fine tensioners. A comparison of five tensioners used in hybrid and ring external fixation. J Orthop Trauma. 2004;18:158-162.
    • (2004) J Orthop Trauma , vol.18 , pp. 158-162
    • Roberts, C.S.1    Antoci, V.2    Antoci Jr., V.3
  • 23
    • 0030011495 scopus 로고    scopus 로고
    • Management of complex tibial plateau fractures with the Ilizarov external fixator
    • Morandi MM, Pearse MF. Management of complex tibial plateau fractures with the Ilizarov external fixator. Tech Orthop. 1996;11:125-131.
    • (1996) Tech Orthop , vol.11 , pp. 125-131
    • Morandi, M.M.1    Pearse, M.F.2
  • 24
  • 25
    • 0032169775 scopus 로고    scopus 로고
    • Stability of external circular fixation: A multi-variable biomechanical analysis
    • Bronson DG, Samchukov ML, Birch JG, et al. Stability of external circular fixation: a multi-variable biomechanical analysis. Clin Biomech. 1998;13:441-448.
    • (1998) Clin Biomech , vol.13 , pp. 441-448
    • Bronson, D.G.1    Samchukov, M.L.2    Birch, J.G.3
  • 26
    • 0036523517 scopus 로고    scopus 로고
    • Reduction techniques used for Ilizarov treatment of tibial fractures
    • Hutson JJ Jr. Reduction techniques used for Ilizarov treatment of tibial fractures. Tech Orthop. 2002;17:34-45.
    • (2002) Tech Orthop , vol.17 , pp. 34-45
    • Hutson Jr., J.J.1
  • 28
    • 0031904941 scopus 로고    scopus 로고
    • Treatment of complex lateral plateau fractures using llizarov techniques
    • Watson JT, Coufal C. Treatment of complex lateral plateau fractures using llizarov techniques. Clin Orthop. 1998;353:97-106.
    • (1998) Clin Orthop , vol.353 , pp. 97-106
    • Watson, J.T.1    Coufal, C.2
  • 29
    • 0032748496 scopus 로고    scopus 로고
    • Tibial pilon fractures: A comparison of treatment methods
    • Pugh KJ, Wolinsky PR, McAndrew MR et al. Tibial pilon fractures: a comparison of treatment methods. J Trauma. 1999;47:937-941.
    • (1999) J Trauma , vol.47 , pp. 937-941
    • Pugh, K.J.1    Wolinsky, P.R.2    McAndrew, M.R.3
  • 30
    • 0028222064 scopus 로고
    • Mechanical forces as predictors of healing during tibial lengthening by distraction osteogcnesis
    • Aronson J, Harp JH Jr. Mechanical forces as predictors of healing during tibial lengthening by distraction osteogcnesis. Clin Orthop. 1994;301:73.
    • (1994) Clin Orthop , vol.301 , pp. 73
    • Aronson, J.1    Harp Jr., J.H.2
  • 31
    • 0024555042 scopus 로고
    • The tension-stress effect on the genesis and grouth of tissues. Part 1: The influence of stability of fixation and soft-tissue preservation
    • Ilizarov GA. The tension-stress effect on the genesis and grouth of tissues. Part 1: the influence of stability of fixation and soft-tissue preservation. Clin Orthop. 1989;238:249-281.
    • (1989) Clin Orthop , vol.238 , pp. 249-281
    • Ilizarov, G.A.1
  • 32
    • 0025073322 scopus 로고
    • Clinical application of the tension-stress effect for limb lengthening
    • Ilizarov G. Clinical application of the tension-stress effect for limb lengthening. Clin Orthop. 1990;250:8-26.
    • (1990) Clin Orthop , vol.250 , pp. 8-26
    • Ilizarov, G.1
  • 33


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.