Modern wireless telecommunication technologies and their electromagnetic compatibility with life-supporting equipment

Author keywords

[No Author keywords available]

Indexed keywords

ANESTHETIC EQUIPMENT; ARTICLE; ARTIFICIAL KIDNEY; DEFIBRILLATOR; DEVICE; DOPPLER ECHOGRAPHY; ELECTRIC FIELD; ELECTROCARDIOGRAM; ELECTROMAGNETIC RADIATION; ELECTRONICS; ELECTROSURGERY; HOSPITAL EQUIPMENT; HUMAN; INCUBATOR; INFUSION PUMP; INTENSIVE CARE UNIT; LABORATORY TEST; LAPAROSCOPY; LIGHT; MASS COMMUNICATION; MEDICAL INSTRUMENTATION; MEDICAL TECHNOLOGY; MOBILE PHONE; MONITOR; OPERATING ROOM; PRIORITY JOURNAL; SAFETY; SUCTION; SURGICAL EQUIPMENT; SWEDEN; TELECOMMUNICATION; TELEMETRY; VENTILATOR; X RAY;

EID: 27444440611     PISSN: 00032999     EISSN: None     Source Type: Journal    
DOI: 10.1213/01.ANE.0000180216.83554.00     Document Type: Article
Times cited : (49)

References (18)
  • 1
    • 85030743754 scopus 로고    scopus 로고
    • Available at: http://www.wirelessmessaging.org/media/info2.0.html. Accessed September 16, 2005.
  • 2
    • 0002587509 scopus 로고
    • Performance degradation of electronic medical devices due to electromagnetic interference
    • Silberberg JL. Performance degradation of electronic medical devices due to electromagnetic interference. Compliance Engineering 1993;10:1-8.
    • (1993) Compliance Engineering , vol.10 , pp. 1-8
    • Silberberg, J.L.1
  • 3
    • 0037385939 scopus 로고    scopus 로고
    • Mobile phones in the hospitals: Past, present and future
    • Klein AA, Djaiani GN. Mobile phones in the hospitals: past, present and future. Anaesthesia 2003;58:353-7.
    • (2003) Anaesthesia , vol.58 , pp. 353-357
    • Klein, A.A.1    Djaiani, G.N.2
  • 5
    • 0033740820 scopus 로고    scopus 로고
    • Electromagnetic interference by GSM cellular phones and UHF radios with intensive care and operating room ventilators
    • Barbaro V, Bartolini P, Baenassi M, et al. Electromagnetic interference by GSM cellular phones and UHF radios with intensive care and operating room ventilators. Biomed Instrum Technol 2000;34:361-9.
    • (2000) Biomed Instrum Technol , vol.34 , pp. 361-369
    • Barbaro, V.1    Bartolini, P.2    Baenassi, M.3
  • 6
    • 0036133650 scopus 로고    scopus 로고
    • Characterization of electromagnetic interference of medical devices due to cell phones
    • Morrisey JJ, Swicord M, Balanzo Q. Characterization of electromagnetic interference of medical devices due to cell phones. Health Phys 2002;82:45-51.
    • (2002) Health Phys , vol.82 , pp. 45-51
    • Morrisey, J.J.1    Swicord, M.2    Balanzo, Q.3
  • 7
    • 0002470979 scopus 로고    scopus 로고
    • Experimental study of electromagnetic interference from cellular phones with electronic medical equipment
    • Baba I, Furuhata H, Kano T, et al. Experimental study of electromagnetic interference from cellular phones with electronic medical equipment. J Clin Engl 1998;23:122-34.
    • (1998) J Clin Engl , vol.23 , pp. 122-134
    • Baba, I.1    Furuhata, H.2    Kano, T.3
  • 8
    • 2942677170 scopus 로고    scopus 로고
    • Mobile phones in the hospital: Improved mobile communication and mitigation of EMI concerns can lead to an overall benefit to healthcare
    • Morrissey JJ. Mobile phones in the hospital: improved mobile communication and mitigation of EMI concerns can lead to an overall benefit to healthcare. Health Phys 2004;87:82-8.
    • (2004) Health Phys , vol.87 , pp. 82-88
    • Morrissey, J.J.1
  • 9
    • 0000932253 scopus 로고    scopus 로고
    • 2.4 GHz WLAN EMI in medical devices
    • Rice WP. 2.4 GHz WLAN EMI in medical devices. J Clin Engl 2000;25:260-4.
    • (2000) J Clin Engl , vol.25 , pp. 260-264
    • Rice, W.P.1
  • 10
    • 0034026962 scopus 로고    scopus 로고
    • Effects of wireless local area network (LAN) system, a telemetry system, and electrosurgical devices on medical devices in a hospital environment
    • Tan KS, Hinberg I. Effects of wireless local area network (LAN) system, a telemetry system, and electrosurgical devices on medical devices in a hospital environment. Biomed Instrum Technol 2000;34:115-8.
    • (2000) Biomed Instrum Technol , vol.34 , pp. 115-118
    • Tan, K.S.1    Hinberg, I.2
  • 12
    • 85030746283 scopus 로고    scopus 로고
    • GSM mobile phone output power distribution by network analysis of all calls in some urban, rural and in-office networks, complemented by test phone measurements
    • Quebec City, Quebec, Canada, June 23-27
    • Persson T, Törnevik C, Larsson LE, Lovén J. GSM mobile phone output power distribution by network analysis of all calls in some urban, rural and in-office networks, complemented by test phone measurements. Bioelectromagnetics (BEMS) Abstract book (p 182) from the Twenty-Fourth Annual Meeting, Quebec City, Quebec, Canada, June 23-27, 2002.
    • (2002) Bioelectromagnetics (BEMS) Abstract Book (P 182) from the Twenty-Fourth Annual Meeting
    • Persson, T.1    Törnevik, C.2    Larsson, L.E.3    Lovén, J.4
  • 15
    • 84970863292 scopus 로고
    • 14,000 Preventable deaths in Australian hospitals
    • Zinn C. 14,000 preventable deaths in Australian hospitals. BMJ 1995;310:1487.
    • (1995) BMJ , vol.310 , pp. 1487
    • Zinn, C.1
  • 17
    • 0037385939 scopus 로고    scopus 로고
    • A response to "Mobile phones in the hospital: Past, present and future"
    • Klein AA, Djaiani GN
    • Halkes M. A response to "Mobile phones in the hospital: past, present and future", Klein AA, Djaiani GN, Anaesthesia 2003;58:353-7.
    • (2003) Anaesthesia , vol.58 , pp. 353-357
    • Halkes, M.1
  • 18
    • 0242301138 scopus 로고    scopus 로고
    • Anaesthesia 2003;58:1147.
    • (2003) Anaesthesia , vol.58 , pp. 1147


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.