메뉴 건너뛰기




Volumn 52, Issue 1, 2005, Pages 11-17

Regulatory measures for implementing new medical devices. Recalling Boneloc®

Author keywords

[No Author keywords available]

Indexed keywords

BONE CEMENT; METHACRYLIC ACID METHYL ESTER; POLY(METHYL METHACRYLATE);

EID: 27344446527     PISSN: 16039629     EISSN: 16039629     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (10)

References (57)
  • 1
    • 0030225634 scopus 로고    scopus 로고
    • Medical devices: Factors adversely affecting innovation
    • Citron P. Medical devices: factors adversely affecting innovation. J Biomed Mat Res 1996; 32 (1): 1-2.
    • (1996) J. Biomed. Mat. Res. , vol.32 , Issue.1 , pp. 1-2
    • Citron, P.1
  • 2
    • 0027284795 scopus 로고
    • The Hydroflex penile prosthesis: A test case for the introduction of new urological technology
    • Riehmann M, Gasser TC, Bruskewitz RC. The Hydroflex penile prosthesis: a test case for the introduction of new urological technology. J Urol 1993; 149 (5): 1304-7.
    • (1993) J. Urol. , vol.149 , Issue.5 , pp. 1304-1307
    • Riehmann, M.1    Gasser, T.C.2    Bruskewitz, R.C.3
  • 3
    • 0032428357 scopus 로고    scopus 로고
    • Absence of longitudinal changes in rheumatologic parameters after silicone breast implantation: A prospective 13-year study
    • Miller AS, Willard V, Kline K, Tarpley S, Guilotte J, Lawler FH, Pendell GM. Absence of longitudinal changes in rheumatologic parameters after silicone breast implantation: a prospective 13-year study. Plast Reconstr Surg 1998; 102 (7): 2299-303.
    • (1998) Plast. Reconstr. Surg. , vol.102 , Issue.7 , pp. 2299-2303
    • Miller, A.S.1    Willard, V.2    Kline, K.3    Tarpley, S.4    Guilotte, J.5    Lawler, F.H.6    Pendell, G.M.7
  • 4
    • 0026743436 scopus 로고
    • Additional mechanical tests of bone cements
    • Hansen D, Jensen JS. Additional mechanical tests of bone cements. Acta Orthop Belg 1992; 58 (3): 268-71.
    • (1992) Acta Orthop. Belg. , vol.58 , Issue.3 , pp. 268-271
    • Hansen, D.1    Jensen, J.S.2
  • 7
    • 0016651077 scopus 로고
    • Side-effects of acrylic cement implanted into bone. A histological, (micro)angiographic, fluorescence-microscopic and autoradiographic study in the rabbit femur
    • Feith R. Side-effects of acrylic cement implanted into bone. A histological, (micro)angiographic, fluorescence-microscopic and autoradiographic study in the rabbit femur. Acta Orthop Scand Suppl 1975; 61: 3-136.
    • (1975) Acta Orthop. Scand. Suppl. , vol.61 , pp. 3-136
    • Feith, R.1
  • 8
    • 0016752522 scopus 로고
    • The influence of acrylic cement on the femur of the dog. A histological study
    • Lindwer J, van den Hooff A. The influence of acrylic cement on the femur of the dog. A histological study. Acta Orthop Scand 1975; 46 (4): 657-71.
    • (1975) Acta Orthop. Scand. , vol.46 , Issue.4 , pp. 657-761
    • Lindwer, J.1    van den Hooff, A.2
  • 9
    • 0017344948 scopus 로고
    • The bone-cement interface temperature during total joint replacement
    • Reckling FW, Dillon WL. The bone-cement interface temperature during total joint replacement. J Bone Joint Surg [Am] 1977; 59 (1): 80-2.
    • (1977) J. Bone Joint Surg. [Am.] , vol.59 , Issue.1 , pp. 80-82
    • Reckling, F.W.1    Dillon, W.L.2
  • 10
    • 0017347569 scopus 로고
    • Reaction of bone to the acute chemical trauma of bone cement
    • Linder L. Reaction of bone to the acute chemical trauma of bone cement. J Bone Joint Surg [Am] 1977; 59 (1): 82-7.
    • (1977) J. Bone Joint Surg. [Am.] , vol.59 , Issue.1 , pp. 82-87
    • Linder, L.1
  • 11
    • 0018349629 scopus 로고
    • Monomer release from methacrylate bone cements during simulated in vivo polymerization
    • Schoenfeld CM, Conard GJ, Lautenschlager EP. Monomer release from methacrylate bone cements during simulated in vivo polymerization. J Biomed Mater Res 1979; 13 (1): 135-47.
    • (1979) J. Biomed. Mater. Res. , vol.13 , Issue.1 , pp. 135-147
    • Schoenfeld, C.M.1    Conard, G.J.2    Lautenschlager, E.P.3
  • 12
    • 84907139157 scopus 로고
    • Loosening of the Cemented Hip Prosthesis
    • Mjöberg B. Loosening of the Cemented Hip Prosthesis. Acta Orthop Scand Suppl 1986; 57 (221): 3-40.
    • (1986) Acta Orthop. Scand. Suppl. , vol.57 , Issue.221 , pp. 3-40
    • Mjöberg, B.1
  • 13
    • 0022346097 scopus 로고
    • Corneal ulcer after exposure to vapours from bone cement (methyl methacrylate and hydroquinone)
    • Nissen J N, Corydon L. Corneal ulcer after exposure to vapours from bone cement (methyl methacrylate and hydroquinone). Int Arch Occup Environ Health 1985; 56 (2): 161-5.
    • (1985) Int. Arch. Occup. Environ. Health , vol.56 , Issue.2 , pp. 161-165
    • Nissen, J.N.1    Corydon, L.2
  • 14
    • 0026744096 scopus 로고
    • Breathing zone concentrations of methylmethacrylate monomer during joint replacement operations
    • Darre E, Jørgensen LG, Vedel P, Jensen JS. Breathing zone concentrations of methylmethacrylate monomer during joint replacement operations. Pharmacol Toxicol 1992; 71 (3): 198-200.
    • (1992) Pharmacol. Toxicol. , vol.71 , Issue.3 , pp. 198-200
    • Darre, E.1    Jørgensen, L.G.2    Vedel, P.3    Jensen, J.S.4
  • 15
    • 0029257107 scopus 로고
    • Innovations in acrylic bone cement and application equipment
    • Kindt-Larsen T, Smith DB, Jensen JS. Innovations in acrylic bone cement and application equipment. J Appl Biomat 1995; 6 (1): 75-83.
    • (1995) J. Appl. Biomat. , vol.6 , Issue.1 , pp. 75-83
    • Kindt-Larsen, T.1    Smith, D.B.2    Jensen, J.S.3
  • 16
    • 0030000333 scopus 로고    scopus 로고
    • Gastroenterology in the last decennia and initiatives in medical ethics: Coincidence or linkage?
    • Thomsen OØ, Riis P. Gastroenterology in the last decennia and initiatives in medical ethics: coincidence or linkage? Scand J Gastroenterol Suppl 1996; 216: 208-17.
    • (1996) Scand. J. Gastroenterol. Suppl. , vol.216 , pp. 208-217
    • Thomsen, O.Ø.1    Riis, P.2
  • 17
    • 0017318635 scopus 로고
    • Forskning under etisk kontrol
    • Riis P. Forskning under etisk kontrol. Ugeskr Læger 1976; 138 (36): 2195-200.
    • (1976) Ugeskr Læger , vol.138 , Issue.36 , pp. 2195-2200
    • Riis, P.1
  • 18
    • 0003491131 scopus 로고    scopus 로고
    • Recommendations guiding physicians in biomedical research involving human subjects
    • World Medical Association (WMA) Declaration of Helsinki. Adopted by the 18th World Medical Assembly in Helsinki, Finland in June 1964, and amended by the 29th World Medical Assembly in Tokyo, Japan in October 1975, and the 35th World Medical Assembly in Venice, Italy in October 1983, the 41th World Medical Assembly in Hong Kong in September 1989, the 48th General Assembly in Somerset West, the Republic of South Africa in October 1996, and 52nd General Assembly in Edinburgh, Scotland, October 7th
    • World Medical Association (WMA) Declaration of Helsinki. Recommendations guiding physicians in biomedical research involving human subjects. Adopted by the 18th World Medical Assembly in Helsinki, Finland in June 1964, and amended by the 29th World Medical Assembly in Tokyo, Japan in October 1975, and the 35th World Medical Assembly in Venice, Italy in October 1983, the 41th World Medical Assembly in Hong Kong in September 1989, the 48th General Assembly in Somerset West, the Republic of South Africa in October 1996, and 52nd General Assembly in Edinburgh, Scotland, October 7th, 2000.
    • (2000)
  • 19
    • 0027304799 scopus 로고
    • European directives on medical devices
    • Ludgate SM, Potter DC. European directives on medical devices. Br Med J 1993; 307 (6902): 459-60.
    • (1993) Br. Med. J. , vol.307 , Issue.6902 , pp. 459-460
    • Ludgate, S.M.1    Potter, D.C.2
  • 20
    • 0030344822 scopus 로고    scopus 로고
    • The medical device directives and their impact on the development and manufacturing of medical implants
    • Crisp S. The medical device directives and their impact on the development and manufacturing of medical implants. Proc Inst Mech Eng H 1996; 210 (4): 233-9.21.
    • (1996) Proc. Inst. Mech. Eng. H. , vol.210 , Issue.4 , pp. 233-921
    • Crisp, S.1
  • 21
    • 27344460899 scopus 로고
    • Council Directive 90/385/EEC of 20 June 1990, on the approximation of the laws of the Member States relating to Active Implantable Medical Devices Directive
    • Commission of the European Communities
    • Council Directive 90/385/EEC of 20 June 1990, on the approximation of the laws of the Member States relating to Active Implantable Medical Devices Directive. Commission of the European Communities. Off J Eur Comm 1990; L 189.
    • (1990) Off J. Eur. Comm. , vol.50 , pp. 189
  • 22
    • 26344471341 scopus 로고
    • Council Directive 93/42/EEC of 14 June 1993, concerning Medical Devices
    • Commission of the European Communities
    • Council Directive 93/42/EEC of 14 June 1993, concerning Medical Devices. Commission of the European Communities. Off J Eur Comm 1993; L 169.
    • (1993) Off J. Eur. Comm. , vol.50 , pp. 169
  • 23
    • 27344458876 scopus 로고    scopus 로고
    • Directive 98/79/EC of the European Parliament and of the Council of October 27, on In-vitro Diagnostic Medical Devices
    • Directive 98/79/EC of the European Parliament and of the Council of October 27, 1998 on In-vitro Diagnostic Medical Devices.
    • (1998)
  • 24
    • 0030605756 scopus 로고    scopus 로고
    • What does the Danish population know about research ethical committees?
    • Holm S, Rossel P. What does the Danish population know about research ethical committees? Ugeskr Læger 1996; 158 (31): 4383-4.
    • (1996) Ugeskr Læger , vol.158 , Issue.31 , pp. 4383-4384
    • Holm, S.1    Rossel, P.2
  • 25
    • 0028989434 scopus 로고
    • Evaluation of Boneloc® Chemical and mechanical properties, and a randomized clinical study of 30 total hip arthroplasties
    • Thanner J, Freij-Larsson C, Kärrholm J, Malchau H, Wesslen B. Evaluation of Boneloc® Chemical and mechanical properties, and a randomized clinical study of 30 total hip arthroplasties. Acta Orthop Scand 1995; 66 (3): 207-14.
    • (1995) Acta Orthop. Scand. , vol.66 , Issue.3 , pp. 207-214
    • Thanner, J.1    Freij-Larsson, C.2    Kärrholm, J.3    Malchau, H.4    Wesslen, B.5
  • 26
    • 0026497237 scopus 로고
    • Acetabular cement temperature in arthroplasty. Effect of water cooling in 19 cases
    • Wykman AGM. Acetabular cement temperature in arthroplasty. Effect of water cooling in 19 cases. Acta Orthop Scand 1992; 63 (5): 543-4.
    • (1992) Acta Orthop. Scand. , vol.63 , Issue.5 , pp. 543-544
    • Wykman, A.G.M.1
  • 27
    • 0029018608 scopus 로고
    • Low polymerization temperature with Boneloc®. In vivo measurements in 11 hip replacements
    • Wykman AGM, Sandersjoo G A. Low polymerization temperature with Boneloc®. In vivo measurements in 11 hip replacements. Acta Orthop Scand 1995; 66 (3): 218-9.
    • (1995) Acta Orthop. Scand. , vol.66 , Issue.3 , pp. 218-219
    • Wykman, A.G.M.1    Sandersjoo, G.A.2
  • 28
    • 0008304447 scopus 로고
    • Clinical results after 2-4 years with a new MMA/DMA/IBMA bone cement used for fixation of the femoral stem
    • Jensen JS, Bødtker S, Kramhøft M, Thomsen PB, Pedersen D, Nielsen K. Clinical results after 2-4 years with a new MMA/DMA/IBMA bone cement used for fixation of the femoral stem. Hip Intern 1995; 5 (1): 31-6.
    • (1995) Hip. Intern. , vol.5 , Issue.1 , pp. 31-36
    • Jensen, J.S.1    Bødtker, S.2    Kramhøft, M.3    Thomsen, P.B.4    Pedersen, D.5    Nielsen, K.6
  • 30
    • 84907139048 scopus 로고
    • Delayed contact hypersensitivity and surgical penetration with acrylic bone cement
    • Jensen JS, Trap B, Skydsgaard K. Delayed contact hypersensitivity and surgical penetration with acrylic bone cement. Acta Orthop Scand 1991; 62 (1): 24-8.
    • (1991) Acta Orthop. Scand. , vol.62 , Issue.1 , pp. 24-28
    • Jensen, J.S.1    Trap, B.2    Skydsgaard, K.3
  • 31
    • 0003054278 scopus 로고
    • Acrylic bone cements: Residuals and extractability of methacrylate monomers and aromatic amines
    • Trap B, Wolff P, Jensen JS. Acrylic bone cements: residuals and extractability of methacrylate monomers and aromatic amines. J Appl Biomat 1992; 3 (1): 51-7.
    • (1992) J. Appl. Biomat. , vol.3 , Issue.1 , pp. 51-57
    • Trap, B.1    Wolff, P.2    Jensen, J.S.3
  • 33
    • 0031465334 scopus 로고    scopus 로고
    • Exeter and Charnley arthroplasties with Boneloc® or high viscosity cement. Comparison of 1,127 arthroplasties followed for 5 years in the Norwegian Arthroplasty Register
    • Furnes O, Lie SA, Havelin LI, Vollset SE, Engesæter LB. Exeter and Charnley arthroplasties with Boneloc® or high viscosity cement. Comparison of 1,127 arthroplasties followed for 5 years in the Norwegian Arthroplasty Register. Acta Orthop Scand 1997; 68 (6): 515-20.
    • (1997) Acta Orthop. Scand. , vol.68 , Issue.6 , pp. 515-520
    • Furnes, O.1    Lie, S.A.2    Havelin, L.I.3    Vollset, S.E.4    Engesæter, L.B.5
  • 34
    • 0028802391 scopus 로고
    • The effect of the type of cement on early revision of cement total hip of Charnley total hip prostheses: A review of eight thousand five hundred and seventy-nine primary arthroplasties from the Norwegian Arthroplasty Register
    • Havelin LI, Espehaug B, Vollset SE, Engesæter LB. The effect of the type of cement on early revision of cement total hip of Charnley total hip prostheses: a review of eight thousand five hundred and seventy-nine primary arthroplasties from the Norwegian Arthroplasty Register. J Bone Joint Surg [Am] 1995; 77 (10): 1543-50.
    • (1995) J. Bone Joint Surg. [Am.] , vol.77 , Issue.10 , pp. 1543-1550
    • Havelin, L.I.1    Espehaug, B.2    Vollset, S.E.3    Engesæter, L.B.4
  • 35
    • 27344441389 scopus 로고
    • The effect of the type of cement on the survival of total hip prostheses
    • Proceedings of the annual meeting of the Norwegian Orthopedic Association, Oslo, Norway. October
    • Havelin LI, Espehaug B, Engesæter LB, Vollset SE. The effect of the type of cement on the survival of total hip prostheses. Proceedings of the annual meeting of the Norwegian Orthopedic Association, Oslo, Norway. October 1994.
    • (1994)
    • Havelin, L.I.1    Espehaug, B.2    Engesæter, L.B.3    Vollset, S.E.4
  • 36
    • 0028989433 scopus 로고
    • Boneloc® - The Christiansen experience revisited
    • Linder L. Boneloc® - The Christiansen experience revisited. Acta Orthop Scand 1995; 66 (3): 205-6.
    • (1995) Acta Orthop. Scand. , vol.66 , Issue.3 , pp. 205-206
    • Linder, L.1
  • 37
    • 0028914203 scopus 로고
    • Early failure with Boneloc® bone cement. 4/8 femoral stems loose within 3 years
    • Suominen S. Early failure with Boneloc® bone cement. 4/8 femoral stems loose within 3 years. Acta Orthop Scand 1995; 66 (1): 13.
    • (1995) Acta Orthop. Scand. , vol.66 , Issue.1 , pp. 13
    • Suominen, S.1
  • 40
    • 0006580242 scopus 로고    scopus 로고
    • Aseptic loosening and clinical result in total hip replacement with the use of Boneloc®, Simplex or Palacos® cement
    • Abstract
    • Daubjerg K, Kaltoft M. Aseptic loosening and clinical result in total hip replacement with the use of Boneloc®, Simplex or Palacos® cement. Abstract. Danish Orthopedic Society Bulletin 1997; 26 (3): 46.
    • (1997) Danish Orthopedic Society Bulletin , vol.26 , Issue.3 , pp. 46
    • Daubjerg, K.1    Kaltoft, M.2
  • 42
    • 0030042735 scopus 로고    scopus 로고
    • Total hip arthroplasty with Boneloc®. Loosening in 102/157 cases after 0.5-3 years
    • Nilsen AR, Wiig M. Total hip arthroplasty with Boneloc®. Loosening in 102/157 cases after 0.5-3 years. Acta Orthop Scand 1996; 67 (1): 57-9.
    • (1996) Acta Orthop. Scand. , vol.67 , Issue.1 , pp. 57-59
    • Nilsen, A.R.1    Wiig, M.2
  • 43
    • 0029935657 scopus 로고    scopus 로고
    • The economic impact of failures in total hip replacement surgery: 28,997 cases from the Norwegian Arthroplasty Register, 1987-1993
    • Furnes A, Lie SA, Havelin LI, Engesæter LB, Vollset SE. The economic impact of failures in total hip replacement surgery: 28,997 cases from the Norwegian Arthroplasty Register, 1987-1993. Acta Orthop Scand 1996; 67 (2): 115-21.
    • (1996) Acta Orthop. Scand. , vol.67 , Issue.2 , pp. 115-121
    • Furnes, A.1    Lie, S.A.2    Havelin, L.I.3    Engesæter, L.B.4    Vollset, S.E.5
  • 45
    • 0031757919 scopus 로고    scopus 로고
    • Inferior performance of Boneloc® bone cement in total knee arthroplasty. A prospective randomized study comparing Boneloc® with Palacos® using radiostereometry (RSA) in 19 patients
    • Nilsson KG, Dalen T. Inferior performance of Boneloc® bone cement in total knee arthroplasty. A prospective randomized study comparing Boneloc® with Palacos® using radiostereometry (RSA) in 19 patients. Acta Orthop Scand 1998; 69 (5): 479-83.
    • (1998) Acta Orthop. Scand. , vol.69 , Issue.5 , pp. 479-483
    • Nilsson, K.G.1    Dalen, T.2
  • 46
    • 0027605123 scopus 로고
    • Improved cortical histology after cementation with a new MMA-DMA-IBMA bone cement: An animal study
    • Nimb L, Stürup J, Jensen JS. Improved cortical histology after cementation with a new MMA-DMA-IBMA bone cement: an animal study. J Biomed Mater Res 1993; 27 (5): 565-74.
    • (1993) J. Biomed. Mater. Res. , vol.27 , Issue.5 , pp. 565-574
    • Nimb, L.1    Stürup, J.2    Jensen, J.S.3
  • 47
    • 0029329097 scopus 로고
    • Blood perfusion and remodelling activity in canine tibial diaphysis after filling with a new bone cement compared to bone wax and poly (methyl methacrylate) cement
    • Stürup J, Nimb L, Jensen JS. Blood perfusion and remodelling activity in canine tibial diaphysis after filling with a new bone cement compared to bone wax and poly (methyl methacrylate) cement. Biomaterials 1995; 16 (11): 845-8.
    • (1995) Biomaterials , vol.16 , Issue.11 , pp. 845-848
    • Stürup, J.1    Nimb, L.2    Jensen, J.S.3
  • 48
    • 0026795145 scopus 로고
    • A quantitative evaluation of periprosthetic bone-remodeling after cementless total hip arthroplasty
    • Engh CA, McGovern TF, Bobyn JD, Harris WH. A quantitative evaluation of periprosthetic bone-remodeling after cementless total hip arthroplasty. J Bone Joint Surg [Am] 1992; 74 (7): 1009-20.
    • (1992) J. Bone Joint Surg. [Am.] , vol.74 , Issue.7 , pp. 1009-1020
    • Engh, C.A.1    McGovern, T.F.2    Bobyn, J.D.3    Harris, W.H.4
  • 49
    • 0022542239 scopus 로고
    • Micromotion in knee arthroplasty. A roentgen stereophotogrammetric analysis of tibial component fixation
    • Ryd L. Micromotion in knee arthroplasty. A roentgen stereophotogrammetric analysis of tibial component fixation. Acta Orthop Scand Suppl 1986; 57 (220): 1-80.
    • (1986) Acta Orthop. Scand. Suppl. , vol.57 , Issue.220 , pp. 1-80
    • Ryd, L.1
  • 51
    • 0027938815 scopus 로고
    • Micromotion of femoral stems in total hip arthroplasty. A randomized study of cemented, hydroxyapatite-coated and porous-coated stems with roentgen stereophotogrammetric analysis
    • Kärrholm J, Malchau H, Snorrason F, Herberts P. Micromotion of femoral stems in total hip arthroplasty. A randomized study of cemented, hydroxyapatite-coated and porous-coated stems with roentgen stereophotogrammetric analysis. J Bone Joint Surg [Am] 1994; 76: 1692-705.
    • (1994) J. Bone Joint Surg. [Am.] , vol.76 , pp. 1692-1705
    • Kärrholm, J.1    Malchau, H.2    Snorrason, F.3    Herberts, P.4
  • 52
    • 0028034860 scopus 로고
    • Does early micromotion of femoral stem prostheses matter? 4-7-year stereoradiographic follow-up of 84 cemented prostheses
    • Kärrholm J, Borssen B, Lowenhielm G, Snorrason F. Does early micromotion of femoral stem prostheses matter? 4-7-year stereoradiographic follow-up of 84 cemented prostheses. J Bone Joint Surg [Br] 1994; 76: 912-7.
    • (1994) J. Bone Joint Surg. [Br.] , vol.76 , pp. 912-917
    • Kärrholm, J.1    Borssen, B.2    Lowenhielm, G.3    Snorrason, F.4
  • 53
    • 27344458216 scopus 로고
    • Personnel communication
    • The Danish Orthopedic Society Meeting, Copenhagen, October 29-30
    • Riegels-Nielsen P. Personnel communication. The Danish Orthopedic Society Meeting, Copenhagen, October 29-30, 1993.
    • (1993)
    • Riegels-Nielsen, P.1
  • 55
    • 27344453532 scopus 로고    scopus 로고
    • Rapport on the role of the Danish National Board of Health in the Boneloc® case
    • May
    • Nielsen LN. Rapport on the role of the Danish National Board of Health in the Boneloc® case. May 1998.
    • (1998)
    • Nielsen, L.N.1
  • 56
    • 0035174918 scopus 로고    scopus 로고
    • Post-marketing surveillance and vigilance for medical devices: The European approach
    • Randall H. Post-marketing surveillance and vigilance for medical devices: the European approach. Drug Saf 2001; 24 (12): 869-72.
    • (2001) Drug Saf. , vol.24 , Issue.12 , pp. 869-872
    • Randall, H.1
  • 57
    • 0003834105 scopus 로고
    • On the Importance of Stepwise Introduction of New Hip Implant Technology
    • Assessment of Total Hip Replacement Using Clinical Evaluation, Radiostereometry, Digitized Radiography, and a National Hip Registry. Thesis. Göteborg
    • Malchau H. On the Importance of Stepwise Introduction of New Hip Implant Technology. Assessment of Total Hip Replacement Using Clinical Evaluation, Radiostereometry, Digitized Radiography, and a National Hip Registry. Thesis. Göteborg 1995.
    • (1995)
    • Malchau, H.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.