Sterile water is unnecessary in a continuous positive airway pressure convection-type humidifier in the treatment of obstructive sleep apnea syndrome

Author keywords

Humidifier; Nasal continuous positive airway pressure; Nonsterile water

Indexed keywords

OXYGEN; PENTETATE TECHNETIUM TC 99M; STERILE WATER; UNCLASSIFIED DRUG; WATER;

EID: 27144495201     PISSN: 00123692     EISSN: None     Source Type: Journal    
DOI: 10.1378/chest.128.4.2138     Document Type: Article
Times cited : (14)

References (9)
  • 1
    • 0021275019 scopus 로고
    • Contaminated condensate in mechanical ventilator circuits: A risk factor for nosocomial pneumonia?
    • Craven DE, Goularte TA, Make BJ. Contaminated condensate in mechanical ventilator circuits: a risk factor for nosocomial pneumonia? Am Rev Respir Dis 1984; 129:625-628
    • (1984) Am Rev Respir Dis , vol.129 , pp. 625-628
    • Craven, D.E.1    Goularte, T.A.2    Make, B.J.3
  • 2
    • 0028968722 scopus 로고
    • Mechanical ventilation with heated humidifiers or heat and moisture exchangers: Effects on patients colonization and incidence of nosocomial pneumonia
    • Dreyfuss D, Djedaini K, Gros I, et al. Mechanical ventilation with heated humidifiers or heat and moisture exchangers: effects on patients colonization and incidence of nosocomial pneumonia. Am J Respir Crit Care Med 1995; 151:986-992
    • (1995) Am J Respir Crit Care Med , vol.151 , pp. 986-992
    • Dreyfuss, D.1    Djedaini, K.2    Gros, I.3
  • 3
    • 0022527566 scopus 로고
    • Bubbling humidifiers produce microaerosols which can carry bacteria
    • Rhame FS, Streifel A, McComb C, et al. Bubbling humidifiers produce microaerosols which can carry bacteria. Am J Infect Control 1986; 7:403-407
    • (1986) Am J Infect Control , vol.7 , pp. 403-407
    • Rhame, F.S.1    Streifel, A.2    McComb, C.3
  • 4
    • 0022512567 scopus 로고
    • Potential in-hospital modes of transmission of Legionella pneumophila: Demonstration experiments for dissemination by showers, humidifiers, and rinsing of ventilation bag apparatus
    • Woo AH, Yu VL, Goetz A. Potential in-hospital modes of transmission of Legionella pneumophila: demonstration experiments for dissemination by showers, humidifiers, and rinsing of ventilation bag apparatus. Am J Med 1986; 80:567-573
    • (1986) Am J Med , vol.80 , pp. 567-573
    • Woo, A.H.1    Yu, V.L.2    Goetz, A.3
  • 5
    • 0028968062 scopus 로고
    • The effects of circuit and humidifier type on contamination potential during mechanical ventilation: A laboratory study
    • Gilmour IJ, Boyle MJ, Streifel A, et al. The effects of circuit and humidifier type on contamination potential during mechanical ventilation: a laboratory study. Am J Infect Control 1995; 23:65-72
    • (1995) Am J Infect Control , vol.23 , pp. 65-72
    • Gilmour, I.J.1    Boyle, M.J.2    Streifel, A.3
  • 6
    • 27144450769 scopus 로고
    • Aerosol generation
    • Mordén F, Newhouse MT, Dolovich MB, eds. Amsterdam, Holland: Elsevier Science Publishers B.V. (Biomedical Division)
    • Swift D. Aerosol generation. In: Mordén F, Newhouse MT, Dolovich MB, eds. Aerosols in medicine: principles, diagnosis and therapy. Amsterdam, Holland: Elsevier Science Publishers B.V. (Biomedical Division), 1985; 64-76
    • (1985) Aerosols in Medicine: Principles, Diagnosis and Therapy , pp. 64-76
    • Swift, D.1
  • 7
    • 0022531991 scopus 로고
    • Lack of bacterial aerosols associated with heat and moisture exchangers
    • Saravolatz LD, Pohlod DJ, Conway W, et al. Lack of bacterial aerosols associated with heat and moisture exchangers. Am Rev Respir Dis 1986; 134:214-216
    • (1986) Am Rev Respir Dis , vol.134 , pp. 214-216
    • Saravolatz, L.D.1    Pohlod, D.J.2    Conway, W.3
  • 8
    • 0034786303 scopus 로고    scopus 로고
    • Bacterial/viral filtration: Let the breather beware!
    • Deniers RR. Bacterial/viral filtration: let the breather beware! Chest 2001; 120:1377-1389
    • (2001) Chest , vol.120 , pp. 1377-1389
    • Deniers, R.R.1
  • 9
    • 0026582722 scopus 로고
    • A comparison of the filtration properties of heat and moisture exchangers
    • Hedley RM, Allt-Graham J, A comparison of the filtration properties of heat and moisture exchangers. Anaesthesia 1992; 47:414-420
    • (1992) Anaesthesia , vol.47 , pp. 414-420
    • Hedley, R.M.1    Allt-Graham, J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.