메뉴 건너뛰기




Volumn 3, Issue , 2005, Pages 2237-2242

Power system subharmonics

Author keywords

Effects; Modeling and simulation; Subharmonics

Indexed keywords

CORE SATURATION; LIGHTNING SYSTEMS; SUBHARMONICS; THERMAL AGING;

EID: 27144475333     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (40)

References (14)
  • 1
    • 0004251094 scopus 로고    scopus 로고
    • IEEE Interharmonic Task Force, "Interharmonic in Power System", http://grouper.ieee.org/groups/harmonic/iharm/docs/.
    • Interharmonic in Power System
  • 3
    • 0346707417 scopus 로고    scopus 로고
    • On the processing of harmonics and interharmonics: Using harming window in standard framework
    • Jan.
    • D.Gallo, R.Langella, A.Testa, "On the Processing of Harmonics and Interharmonics: Using Harming Window in Standard Framework", IEEE Transaction on Power Delivery. Vol. 19 Issue: 1, Jan. 2004.
    • (2004) IEEE Transaction on Power Delivery , vol.19 , Issue.1
    • Gallo, D.1    Langella, R.2    Testa, A.3
  • 4
    • 13244265761 scopus 로고    scopus 로고
    • Issues related to interharmonics
    • invited paper, Denver, USA, June
    • A. Testa, "Issues Related to Interharmonics", invited paper at IEEE Annual Power Meeting 2004, Denver, USA, June 2004.
    • (2004) IEEE Annual Power Meeting 2004
    • Testa, A.1
  • 6
    • 27144547036 scopus 로고    scopus 로고
    • On the effects of voltage subharmonics on power transformers: A preliminary study IEC flickermeter response to interharmonic pollution
    • Lake Placid, U.S.A., Sept. 12-15
    • D. Gallo, R. Langella, A. Testa, A. Emanuel, "On the Effects of Voltage Subharmonics on Power Transformers: A preliminary study IEC Flickermeter Response to Interharmonic Pollution", ICHQP 2004, Lake Placid, U.S.A., Sept. 12-15, 2004.
    • (2004) ICHQP 2004
    • Gallo, D.1    Langella, R.2    Testa, A.3    Emanuel, A.4
  • 7
    • 82955224780 scopus 로고    scopus 로고
    • The need to limit subharmonic injection
    • Orlando, USA, Oct.
    • J. A. Emanuel: "The Need to Limit Subharmonic Injection", ICHQP 2000, Orlando, USA, Oct.2000.
    • (2000) ICHQP 2000
    • Emanuel, J.A.1
  • 8
    • 27144449036 scopus 로고    scopus 로고
    • Proposed steady-state limits for turbine-generator torsional response
    • invited paper Chicago, USA, July grouper.ieee.org/groups/harmonic/iharm/ docs
    • C. Bowler, "Proposed Steady-State Limits for Turbine-Generator Torsional Response", invited paper at IEEE Summer Power Meeting 2002, Chicago, USA, July 2002, grouper.ieee.org/groups/harmonic/iharm/docs/.
    • (2002) IEEE Summer Power Meeting 2002
    • Bowler, C.1
  • 10
    • 0012849519 scopus 로고
    • Flicker caused by interharmonic
    • W. Mombauer, etz Archiv BD.12 (1990) H. 12, S.391-396, "Flicker Caused by Interharmonic".
    • (1990) Etz Archiv , vol.12 , Issue.12 , pp. 391-396
    • Mombauer, W.1
  • 12
    • 27144522595 scopus 로고    scopus 로고
    • Test protocol of IEC Flickermeter use in power system voltage monitoring
    • Draft 8 May
    • CCU2 WG on Voltage Quality: "Test protocol of IEC Flickermeter use in power system voltage monitoring", Draft 8 May 2003.
    • (2003) CCU2 WG on Voltage Quality
  • 13
    • 0036255431 scopus 로고    scopus 로고
    • Induction motor thermal aging caused by voltage distortion and imbalance: Loss of useful life and its estimated cost
    • January/February
    • J. Policarpo G. de Abreu and A. E. Emanuel, "Induction Motor Thermal Aging Caused by Voltage Distortion and Imbalance: Loss of Useful Life and Its Estimated Cost", IEEE Trans. On Ind. App., vol. 38, n. 1, January/February 2002.
    • (2002) IEEE Trans. on Ind. App. , vol.38 , Issue.1
    • Policarpo, J.1    De Abreu, G.2    Emanuel, A.E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.