메뉴 건너뛰기




Volumn 27, Issue SUPPL. 1, 2005, Pages

Influence of stent properties on the alteration of cerebral intra-aneurysmal haemodynamics: Flow quantification in elastic sidewall aneurysm models

Author keywords

Aneurysm; Cerebral; Haemodynamics; In vitro; Stent

Indexed keywords

GLASS; SILICONE;

EID: 27144457658     PISSN: 01616412     EISSN: None     Source Type: Journal    
DOI: 10.1179/016164105X35477     Document Type: Article
Times cited : (49)

References (38)
  • 1
    • 0026808426 scopus 로고
    • Endovascular treatment of posterior circulation aneurysms by electrothrombosis using electrically detachable coils
    • Guglielmi G, Vinuela F, Duckwiler G, et al. Endovascular treatment of posterior circulation aneurysms by electrothrombosis using electrically detachable coils. J Neurosurg 1992; 77: 515-524
    • (1992) J Neurosurg , vol.77 , pp. 515-524
    • Guglielmi, G.1    Vinuela, F.2    Duckwiler, G.3
  • 2
    • 0036141143 scopus 로고    scopus 로고
    • Endovascular treatment of intracranial aneurysms with Guglielmi detachable coils: Analysis of midterm angiographic and clinical outcomes
    • Ng P, Khangure MS, Phatouros CC, et al. Endovascular treatment of intracranial aneurysms with Guglielmi detachable coils: analysis of midterm angiographic and clinical outcomes. Stroke 2002; 33: 210-217
    • (2002) Stroke , vol.33 , pp. 210-217
    • Ng, P.1    Khangure, M.S.2    Phatouros, C.C.3
  • 3
    • 0034433325 scopus 로고    scopus 로고
    • Natural history of the neck remnant of a cerebral aneurysm treated with the Guglielmi detachable coil system
    • Hayakawa M, Murayama Y, Duckwiler GR, et al. Natural history of the neck remnant of a cerebral aneurysm treated with the Guglielmi detachable coil system. J Neurosurg 2000; 93: 561-568
    • (2000) J Neurosurg , vol.93 , pp. 561-568
    • Hayakawa, M.1    Murayama, Y.2    Duckwiler, G.R.3
  • 4
    • 0037673806 scopus 로고
    • Changes in arterial distensibility as a cause of poststenotic dilatation
    • Roach MR. Changes in arterial distensibility as a cause of poststenotic dilatation. Am J Cardiol 1963; 802-815
    • (1963) Am J Cardiol , pp. 802-815
    • Roach, M.R.1
  • 5
    • 0036263073 scopus 로고    scopus 로고
    • Partially clipped intracranial aneurysm obliterated with combined stent and coil implantation
    • Lylyk P, Cohen JE, Ferrario A, et al. Partially clipped intracranial aneurysm obliterated with combined stent and coil implantation. J Endovasc Ther 2002; 9: 160-164
    • (2002) J Endovasc Ther , vol.9 , pp. 160-164
    • Lylyk, P.1    Cohen, J.E.2    Ferrario, A.3
  • 6
    • 0034871096 scopus 로고    scopus 로고
    • Combined endovascular treatment of dissecting vertebral artery aneurysms by using stents and coils
    • Lylyk P, Cohen JE, Ceratto R, et al. Combined endovascular treatment of dissecting vertebral artery aneurysms by using stents and coils. J Neurosurg 2001; 94: 427-432
    • (2001) J Neurosurg , vol.94 , pp. 427-432
    • Lylyk, P.1    Cohen, J.E.2    Ceratto, R.3
  • 7
    • 0031752794 scopus 로고    scopus 로고
    • Stenting and secondary coiling of intracranial internal carotid artery aneurysm: Technical case report
    • Mericle RA, Lanzino G, Wakhloo AK, et al. Stenting and secondary coiling of intracranial internal carotid artery aneurysm: technical case report. Neurosurgery 1998; 43: 1229-1234
    • (1998) Neurosurgery , vol.43 , pp. 1229-1234
    • Mericle, R.A.1    Lanzino, G.2    Wakhloo, A.K.3
  • 8
    • 0029101345 scopus 로고
    • Endovascular stent placement for multiple aneurysms of the extracranial internal carotid artery: Technical case report
    • Mase M, Banno T, Yamada K, et al. Endovascular stent placement for multiple aneurysms of the extracranial internal carotid artery: technical case report. Neurosurgery 1995; 37: 832-835
    • (1995) Neurosurgery , vol.37 , pp. 832-835
    • Mase, M.1    Banno, T.2    Yamada, K.3
  • 9
    • 0034879696 scopus 로고    scopus 로고
    • Intravascular stent placement for a fusiform aneurysm of the posterior cerebral artery: Case report
    • Brassel F, Rademaker J, Haupt C, et al. Intravascular stent placement for a fusiform aneurysm of the posterior cerebral artery: case report. Eur Radiol 2001; 11: 1250-1253.
    • (2001) Eur Radiol , vol.11 , pp. 1250-1253
    • Brassel, F.1    Rademaker, J.2    Haupt, C.3
  • 10
    • 0028302797 scopus 로고
    • Combined use of stents and coils to treat experimental wide-necked carotid aneurysms: Preliminary results
    • Szikora I, Guterman LR, Wells KM, et al. Combined use of stents and coils to treat experimental wide-necked carotid aneurysms: preliminary results. Am J Neurol Res Am J Neuroradiol 1994; 15: 1091-1102
    • (1994) Am J Neurol Res Am J Neuroradiol , vol.15 , pp. 1091-1102
    • Szikora, I.1    Guterman, L.R.2    Wells, K.M.3
  • 11
    • 0036629467 scopus 로고    scopus 로고
    • Changes of flow characteristics by stenting in aneurysm models: Influence of aneurysm geometry and stent porosity
    • Rhee K, Han MH, Cha SH. Changes of flow characteristics by stenting in aneurysm models: influence of aneurysm geometry and stent porosity. Ann Biomed Eng 2002; 30: 894-904
    • (2002) Ann Biomed Eng , vol.30 , pp. 894-904
    • Rhee, K.1    Han, M.H.2    Cha, S.H.3
  • 12
    • 0035982808 scopus 로고    scopus 로고
    • Particle image velocimetry assessment of stent design influence on intra-aneurysmal flow
    • Lieber BB, Livescu V, Hopkins LN, et al. Particle image velocimetry assessment of stent design influence on intra-aneurysmal flow. Ann Biomed Eng 2002; 30: 768-777
    • (2002) Ann Biomed Eng , vol.30 , pp. 768-777
    • Lieber, B.B.1    Livescu, V.2    Hopkins, L.N.3
  • 13
    • 0033494069 scopus 로고    scopus 로고
    • Efficacy and current limitations of intravascular stents for intracranial internal carotid, vertebral, and basilar artery aneurysms
    • Lanzino G, Wakhloo AK, Fessler RD, et al. Efficacy and current limitations of intravascular stents for intracranial internal carotid, vertebral, and basilar artery aneurysms. J Neurosurg 1999; 91: 538-546
    • (1999) J Neurosurg , vol.91 , pp. 538-546
    • Lanzino, G.1    Wakhloo, A.K.2    Fessler, R.D.3
  • 14
    • 0002751522 scopus 로고    scopus 로고
    • Effective medium approximation and deposition of colloidal particles in fibrous and granular media
    • Li Y, Park CW. Effective medium approximation and deposition of colloidal particles in fibrous and granular media. Advances in Colloid and Interface Science 2000; 87: 1-74
    • (2000) Advances in Colloid and Interface Science , vol.87 , pp. 1-74
    • Li, Y.1    Park, C.W.2
  • 15
    • 0029166823 scopus 로고
    • Computer modeling of intracranial saccular and lateral aneurysms for the study of their hemodynamics
    • discussion 782-784
    • Burleson AC, Strother CM, Turitto VT. Computer modeling of intracranial saccular and lateral aneurysms for the study of their hemodynamics. Neurosurgery 1995; 37: 774-782; discussion 782-784
    • (1995) Neurosurgery , vol.37 , pp. 774-782
    • Burleson, A.C.1    Strother, C.M.2    Turitto, V.T.3
  • 16
    • 0001545264 scopus 로고    scopus 로고
    • LDV measurements in lateral model aneurysms of various sizes
    • Liou TM, Chang WC, Liao CC. LDV measurements in lateral model aneurysms of various sizes. Exp Fluids 1997; 23: 317-324
    • (1997) Exp Fluids , vol.23 , pp. 317-324
    • Liou, T.M.1    Chang, W.C.2    Liao, C.C.3
  • 17
    • 0001040921 scopus 로고
    • Observations on the relationship between the volume and the size of the orifice of experimental aneurysms
    • SPW Black, German WJ. Observations on the relationship between the volume and the size of the orifice of experimental aneurysms. J Neurosurg 1960; 60: 984-990
    • (1960) J Neurosurg , vol.60 , pp. 984-990
    • Black, S.P.W.1    German, W.J.2
  • 18
    • 0027361852 scopus 로고
    • Hemodynamics in rigid and distensible saccular aneurysms: A numerical study of pulsatile flow characteristics
    • Low M, Perktold K, Raunig R. Hemodynamics in rigid and distensible saccular aneurysms: a numerical study of pulsatile flow characteristics. Biorheology 1993; 30: 287-298
    • (1993) Biorheology , vol.30 , pp. 287-298
    • Low, M.1    Perktold, K.2    Raunig, R.3
  • 19
    • 0021636725 scopus 로고
    • Pulsatile flow of non-Newtonian fluid in distensible models of human arteries
    • Liepsch D, Moravec S. Pulsatile flow of non-Newtonian fluid in distensible models of human arteries. Biorheology 1984; 21: 571-586
    • (1984) Biorheology , vol.21 , pp. 571-586
    • Liepsch, D.1    Moravec, S.2
  • 20
    • 0042492119 scopus 로고
    • The relation of hypertension to arterial aneurysms of the brain
    • Black B.K, Hicks, SP. The relation of hypertension to arterial aneurysms of the brain. US Armed Forces Med J 1952; 3: 1813-1818
    • (1952) US Armed Forces Med J , vol.3 , pp. 1813-1818
    • Black, B.K.1    Hicks, S.P.2
  • 21
    • 0034209818 scopus 로고    scopus 로고
    • Intracranial aneurysms and arterial hypertension: A review and hypothesis
    • discussion 540-542
    • Inci S, Spetzler RF. Intracranial aneurysms and arterial hypertension: a review and hypothesis. Surg Neurol 2000; 53: 530-540; discussion 540-542
    • (2000) Surg Neurol , vol.53 , pp. 530-540
    • Inci, S.1    Spetzler, R.F.2
  • 22
    • 0242587785 scopus 로고
    • Hemodynamic stress in lateral saccular aneurysms
    • Liepsch DW, Steiger HJ, Poll A, et al. Hemodynamic stress in lateral saccular aneurysms. Biorheology 1987; 24: 689-710
    • (1987) Biorheology , vol.24 , pp. 689-710
    • Liepsch, D.W.1    Steiger, H.J.2    Poll, A.3
  • 23
    • 0023223076 scopus 로고
    • Haemodynamic stress in lateral saccular aneurysms. An experimental study
    • Steiger HJ, Poll A, Liepsch D, Reulen HJ. Haemodynamic stress in lateral saccular aneurysms. An experimental study. Acta Neurochir (Wien) 1987; 86: 98-105
    • (1987) Acta Neurochir (Wien) , vol.86 , pp. 98-105
    • Steiger, H.J.1    Poll, A.2    Liepsch, D.3    Reulen, H.J.4
  • 24
    • 0026521382 scopus 로고
    • Flow dynamics of lateral carotid artery aneurysms and their effects on coils and balloons: An experimental study in dogs
    • Graves VB, Strother CM, Partington CR, et al. Flow dynamics of lateral carotid artery aneurysms and their effects on coils and balloons: an experimental study in dogs. Am J Neurol Res Am J Neuroradiol 1992; 13: 189-196
    • (1992) Am J Neurol Res Am J Neuroradiol , vol.13 , pp. 189-196
    • Graves, V.B.1    Strother, C.M.2    Partington, C.R.3
  • 25
    • 0028136558 scopus 로고
    • Embolization of experimentally created aneurysms with intravascular stent devices
    • Geremia G, Haklin M, Brennecke L. Embolization of experimentally created aneurysms with intravascular stent devices. Am J Neurol Res Am J Neuroradiol 1994; 15: 1223-1231
    • (1994) Am J Neurol Res Am J Neuroradiol , vol.15 , pp. 1223-1231
    • Geremia, G.1    Haklin, M.2    Brennecke, L.3
  • 26
    • 0031148733 scopus 로고    scopus 로고
    • Alteration of hemodynamics in aneurysm models by stenting: Influence of stent porosity
    • Lieber BB, Stancampiano AP, Wakhloo AK. Alteration of hemodynamics in aneurysm models by stenting: influence of stent porosity. Ann Biomed Eng 1997; 25: 460-469
    • (1997) Ann Biomed Eng , vol.25 , pp. 460-469
    • Lieber, B.B.1    Stancampiano, A.P.2    Wakhloo, A.K.3
  • 27
    • 16644374127 scopus 로고    scopus 로고
    • Anatomically shaped internal carotid artery aneurysm in vitro model for flow analysis to evaluate stent effect
    • Baráth K, Cassot F, Rüfenacht DA, et al. Anatomically shaped internal carotid artery aneurysm in vitro model for flow analysis to evaluate stent effect. Am J Neuroradiol 2004; 25: 1750-1759
    • (2004) Am J Neuroradiol , vol.25 , pp. 1750-1759
    • Baráth, K.1    Cassot, F.2    Rüfenacht, D.A.3
  • 28
    • 0021238192 scopus 로고
    • Calculation of pulsatile flow and particle paths in an aneurysm-model
    • Perktold K, Gruber K, Kenner T, et al. Calculation of pulsatile flow and particle paths in an aneurysm-model. Basic Res Cardiol 1984; 79: 253-261
    • (1984) Basic Res Cardiol , vol.79 , pp. 253-261
    • Perktold, K.1    Gruber, K.2    Kenner, T.3
  • 29
    • 0032773494 scopus 로고    scopus 로고
    • A steady flow analysis on the stented and nonstented sidewall aneurysm models
    • Yu SC, Zhao JB. A steady flow analysis on the stented and nonstented sidewall aneurysm models. Med Eng Phys 1999; 21: 133-141
    • (1999) Med Eng Phys , vol.21 , pp. 133-141
    • Yu, S.C.1    Zhao, J.B.2
  • 30
    • 0037393677 scopus 로고    scopus 로고
    • Image-based computational simulation of flow dynamics in a giant intracranial aneurysm
    • Steinman DA, Milner JS, Norley CJ, et al. Image-based computational simulation of flow dynamics in a giant intracranial aneurysm. Am J Neurol Res Am J Neuroradiol 2003; 24: 559-566
    • (2003) Am J Neurol Res Am J Neuroradiol , vol.24 , pp. 559-566
    • Steinman, D.A.1    Milner, J.S.2    Norley, C.J.3
  • 31
    • 0026607672 scopus 로고
    • Intracranial aneurysms: Flow analysis of their origin and progression
    • Gonzales CF, Cho YI, Ortega HV, et al. Intracranial aneurysms: flow analysis of their origin and progression. Am J Neurol Res Am J Neuroradiol 1992; 13: 181-188
    • (1992) Am J Neurol Res Am J Neuroradiol , vol.13 , pp. 181-188
    • Gonzales, C.F.1    Cho, Y.I.2    Ortega, H.V.3
  • 32
    • 0031148814 scopus 로고    scopus 로고
    • Modeling of flow in a straight stented and nonstented side wall aneurysm model
    • Aenis M, Stancampiano AP, Wakhloo AK, et al. Modeling of flow in a straight stented and nonstented side wall aneurysm model. J Biomech Eng 1997; 119: 206-212
    • (1997) J Biomech Eng , vol.119 , pp. 206-212
    • Aenis, M.1    Stancampiano, A.P.2    Wakhloo, A.K.3
  • 34
    • 0015868665 scopus 로고
    • Postoperative angiography and the 'slipped' clip
    • Drake CG, Allcock JM. Postoperative angiography and the 'slipped' clip. J Neurosurg 1973; 39: 683-689
    • (1973) J Neurosurg , vol.39 , pp. 683-689
    • Drake, C.G.1    Allcock, J.M.2
  • 35
    • 0024514716 scopus 로고
    • Regrowth of aneurysm sacs from residual neck following aneurysm clipping
    • Lin T, Fox AJ, Drake CG. Regrowth of aneurysm sacs from residual neck following aneurysm clipping. J Neurosurg 1989; 70: 556-560
    • (1989) J Neurosurg , vol.70 , pp. 556-560
    • Lin, T.1    Fox, A.J.2    Drake, C.G.3
  • 36
    • 0035052532 scopus 로고    scopus 로고
    • Analysis of slipstream flow in a wide-necked basilar artery aneurysm: Evaluation of potential treatment regimens
    • Imbesi SG, Kerber CW. Analysis of slipstream flow in a wide-necked basilar artery aneurysm: evaluation of potential treatment regimens. Am J Neurol Res Am J Neuroradiol 2001; 22: 721-724
    • (2001) Am J Neurol Res Am J Neuroradiol , vol.22 , pp. 721-724
    • Imbesi, S.G.1    Kerber, C.W.2
  • 37
    • 0028224513 scopus 로고
    • Self-expanding and balloon-expandable stents in the treatment of carotid aneurysms: An experimental study in a canine model
    • Wakhloo AK, Schellhammer F, de Vries J, et al. Self-expanding and balloon-expandable stents in the treatment of carotid aneurysms: an experimental study in a canine model. Am J Neurol Res Am J Neuroradiol 1994; 15: 493-502
    • (1994) Am J Neurol Res Am J Neuroradiol , vol.15 , pp. 493-502
    • Wakhloo, A.K.1    Schellhammer, F.2    De Vries, J.3
  • 38
    • 0036286337 scopus 로고    scopus 로고
    • The physics of endoluminal stenting in the treatment of cerebrovascular aneurysms
    • Lieber BB, Gounis MJ. The physics of endoluminal stenting in the treatment of cerebrovascular aneurysms. Neurol Res 2002; 24 Suppl 1: S33-42
    • (2002) Neurol Res , vol.24 , Issue.SUPPL. 1
    • Lieber, B.B.1    Gounis, M.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.