메뉴 건너뛰기




Volumn 52, Issue 2, 2005, Pages 101-107

Hand circulation after radial artery harvest for coronary artery bypass grafting

Author keywords

Coronary artery bypass grafting; Radial artery

Indexed keywords

BLOOD FLOW; CORONARY ARTERY BYPASS GRAFT; DOPPLER FLOWMETRY; ECHOGRAPHY; FOREARM; HAND; HAND GRIP; HUMAN; ISCHEMIA; PLETHYSMOGRAPHY; RADIAL ARTERY; REVIEW; TRANSPLANTATION; ULNAR ARTERY; VASCULARIZATION;

EID: 26944462770     PISSN: 13428810     EISSN: 13428810     Source Type: Journal    
DOI: None     Document Type: Review
Times cited : (22)

References (45)
  • 1
    • 0015704705 scopus 로고
    • The aorta-to-coronary radial artery bypass graft: a technique avoiding pathological changes in grafts
    • Carpentier A, Guermonprez JL, Deloche A, et al. The aorta-to-coronary radial artery bypass graft: a technique avoiding pathological changes in grafts. Ann Thorac Surg 1973;16:111-121
    • (1973) Ann Thorac Surg , vol.16 , pp. 111-121
    • Carpentier, A.1    Guermonprez, J.L.2    Deloche, A.3
  • 2
    • 0016827392 scopus 로고
    • Selection of coronary bypass: anatomic, physiologic, and angiographic considerations of vein and mammary artery grafts
    • Carpentier A. Discussion of Geha AS, Krone RJ, McCormick JR, et al. Selection of coronary bypass: anatomic, physiologic, and angiographic considerations of vein and mammary artery grafts. J Thorac Cardiovasc Surg 1975;70:414-431
    • (1975) J Thorac Cardiovasc Surg , vol.70 , pp. 414-431
    • Carpentier, A.1    Discussion of Geha, A.S.2    Krone, R.J.3    McCormick, J.R.4
  • 3
    • 0026480558 scopus 로고
    • Revival of the radial artery for coronary artery bypass grafting
    • Acar C, Jebara VA, Portoghese M, et al. Revival of the radial artery for coronary artery bypass grafting. Ann Thorac Surg 1992;54:652-660
    • (1992) Ann Thorac Surg , vol.54 , pp. 652-660
    • Acar, C.1    Jebara, V.A.2    Portoghese, M.3
  • 4
    • 9244237570 scopus 로고    scopus 로고
    • A randomized comparison of radial-artery and saphenous-vein coronary bypass grafs
    • Desai ND, Cohen EA, Naylor CD, et al. A randomized comparison of radial-artery and saphenous-vein coronary bypass grafs. N Engl J Med 2004;351:2302-2309
    • (2004) N Engl J Med , vol.351 , pp. 2302-2309
    • Desai, N.D.1    Cohen, E.A.2    Naylor, C.D.3
  • 5
    • 14244265934 scopus 로고    scopus 로고
    • Effects of postoperative administration of diltiazem on renal function following coronary artery bypass grafting
    • Manabe S, Tanaka H, Yoshizaki T, et al. Effects of postoperative administration of diltiazem on renal function following coronary artery bypass grafting. Ann Thorac Surg 2005;79:831-836
    • (2005) Ann Thorac Surg , vol.79 , pp. 831-836
    • Manabe, S.1    Tanaka, H.2    Yoshizaki, T.3
  • 6
    • 0036147974 scopus 로고    scopus 로고
    • The radial artery in coronary surgery: 5-year experience-clinical and angiographic results
    • Tatoulis J, Royse AG, Buxton BF, et al. The radial artery in coronary surgery: 5-year experience-clinical and angiographic results. Ann Thorac Surg 2002;73:143-148
    • (2002) Ann Thorac Surg , vol.73 , pp. 143-148
    • Tatoulis, J.1    Royse, A.G.2    Buxton, B.F.3
  • 7
    • 0032943440 scopus 로고    scopus 로고
    • Acute upper limb ischemia: a complication of coronary artery bypass grafting
    • Fox AD, Whiteley MS, Phillips-Hughes J, et al. Acute upper limb ischemia: a complication of coronary artery bypass grafting. Ann Thorac Surg 1999;67:535-537
    • (1999) Ann Thorac Surg , vol.67 , pp. 535-537
    • Fox, A.D.1    Whiteley, M.S.2    Phillips-Hughes, J.3
  • 8
    • 0032169229 scopus 로고    scopus 로고
    • An unexpected complication after harvesting of the radial artery for coronary artery bypass grafting
    • Nunoo-Mensah J. An unexpected complication after harvesting of the radial artery for coronary artery bypass grafting. Ann Thorac Surg 1998;66:929-931
    • (1998) Ann Thorac Surg , vol.66 , pp. 929-931
    • Nunoo-Mensah, J.1
  • 9
    • 0036905568 scopus 로고    scopus 로고
    • Measurement of ulnar flow is helpful in predicting ischemia after radial artery harvest
    • Manabe S, Tabuchi N, Toyama M, et al. Measurement of ulnar flow is helpful in predicting ischemia after radial artery harvest. Thorac Cardiovasc Surg 2002;50:325-328
    • (2002) Thorac Cardiovasc Surg , vol.50 , pp. 325-328
    • Manabe, S.1    Tabuchi, N.2    Toyama, M.3
  • 10
    • 0036634834 scopus 로고    scopus 로고
    • An evaluation of the potential ischemia of the forearm after harvesting of radial artery by near infrared spectroscopy
    • (in Japanese, English abstract)
    • Fukada Y, Matsui Y, Yamauchi H, et al. An evaluation of the potential ischemia of the forearm after harvesting of radial artery by near infrared spectroscopy. (in Japanese, English abstract) Kyobu geka 2002;55:549-553
    • (2002) Kyobu geka , vol.55 , pp. 549-553
    • Fukada, Y.1    Matsui, Y.2    Yamauchi, H.3
  • 12
    • 0029909188 scopus 로고    scopus 로고
    • Safe removal of the radial artery for myocardial revascularization: Doppler study to prevent ischemic complications to the hand
    • Pola P, Serricchio M, Flore R, et al. Safe removal of the radial artery for myocardial revascularization: Doppler study to prevent ischemic complications to the hand. J Thorac Cardiovasc Surg 1996;112:737-744
    • (1996) J Thorac Cardiovasc Surg , vol.112 , pp. 737-744
    • Pola, P.1    Serricchio, M.2    Flore, R.3
  • 13
    • 0032851418 scopus 로고    scopus 로고
    • New noninvasive test alternative to Allen's test: snuff-box technique
    • Kochi K, Sueda T, Orihashi K, et al. New noninvasive test alternative to Allen's test: snuff-box technique. J Thorac Cardiovasc Surg 1999;118:756-758
    • (1999) J Thorac Cardiovasc Surg , vol.118 , pp. 756-758
    • Kochi, K.1    Sueda, T.2    Orihashi, K.3
  • 14
    • 0037393985 scopus 로고    scopus 로고
    • The snuffbox technique: reliable color Doppler method to assess hand circulation
    • Kochi K, Orihashi K, Sueda T. The snuffbox technique: reliable color Doppler method to assess hand circulation. J Thorac Cardiovasc Surg 2003;125:821-825
    • (2003) J Thorac Cardiovasc Surg , vol.125 , pp. 821-825
    • Kochi, K.1    Orihashi, K.2    Sueda, T.3
  • 15
    • 0034170310 scopus 로고    scopus 로고
    • Duplex scanning to assess radial artery suitability for coronary artery bypass grafting
    • Hosono M, Suehiro S, Shibata T, et al. Duplex scanning to assess radial artery suitability for coronary artery bypass grafting. Jpn J Thorac Cardiovasc Surg 2000;48:217-221
    • (2000) Jpn J Thorac Cardiovasc Surg , vol.48 , pp. 217-221
    • Hosono, M.1    Suehiro, S.2    Shibata, T.3
  • 16
    • 0035069596 scopus 로고    scopus 로고
    • Preoperative assessment of hand circulation by means of doppler ultrasonography and the modified Allen test
    • Ruengsakulrach P, Brooks M, Hare DL, et al. Preoperative assessment of hand circulation by means of doppler ultrasonography and the modified Allen test. J Thorac Cardiovasc Surg 2001;121:526-531
    • (2001) J Thorac Cardiovasc Surg , vol.121 , pp. 526-531
    • Ruengsakulrach, P.1    Brooks, M.2    Hare, D.L.3
  • 17
    • 0032905056 scopus 로고    scopus 로고
    • Noninvasive evaluation of hand circulation before radial artery harvest for coronary artery bypass grafting
    • Starnes SL, Wolk SW, Lampman RM, et al. Noninvasive evaluation of hand circulation before radial artery harvest for coronary artery bypass grafting. J Thorac Cardiovasc Surg 1999;117:261-266
    • (1999) J Thorac Cardiovasc Surg , vol.117 , pp. 261-266
    • Starnes, S.L.1    Wolk, S.W.2    Lampman, R.M.3
  • 18
    • 0035128732 scopus 로고    scopus 로고
    • The role of preoperative radial artery ultrasound and digital plethysmography prior to coronary artery bypass grafting
    • Rodriguez E, Ormont ML, Lambert EH, et al. The role of preoperative radial artery ultrasound and digital plethysmography prior to coronary artery bypass grafting. Eur J Cardiothorac Surg 2001;19:135-139
    • (2001) Eur J Cardiothorac Surg , vol.19 , pp. 135-139
    • Rodriguez, E.1    Ormont, M.L.2    Lambert, E.H.3
  • 19
    • 0032076458 scopus 로고    scopus 로고
    • Radial artery use in bypass grafting does not change digital blood flow or hand function
    • Dumanian GA, Segalman K, Mispireta LA, et al. Radial artery use in bypass grafting does not change digital blood flow or hand function. Ann Thorac Surg 1998;65:1284-1287
    • (1998) Ann Thorac Surg , vol.65 , pp. 1284-1287
    • Dumanian, G.A.1    Segalman, K.2    Mispireta, L.A.3
  • 20
    • 0036521126 scopus 로고    scopus 로고
    • Effect of radial artery harvest on collateral forearm blood flow and digital perfusion
    • Brodman RF, Hirsh LE, Frame R. Effect of radial artery harvest on collateral forearm blood flow and digital perfusion. J Thorac Cardiovasc Surg 2002;123:512-516
    • (2002) J Thorac Cardiovasc Surg , vol.123 , pp. 512-516
    • Brodman, R.F.1    Hirsh, L.E.2    Frame, R.3
  • 21
    • 0029071142 scopus 로고
    • Anomalies of forearm vascular anatomy encountered during elevation of the radial forearm flap
    • Funk GF, Valentino J, McCulloch TM, et al. Anomalies of forearm vascular anatomy encountered during elevation of the radial forearm flap. Head Neck 1995;17:284-292
    • (1995) Head Neck , vol.17 , pp. 284-292
    • Funk, G.F.1    Valentino, J.2    McCulloch, T.M.3
  • 22
    • 0021846956 scopus 로고
    • Acute ischaemia of the hand resulting from elevation of a radial forearm flap
    • Jones BM, O'Brien CJ. Acute ischaemia of the hand resulting from elevation of a radial forearm flap. Br J Plas surg 1985;38:396-397
    • (1985) Br J Plas surg , vol.38 , pp. 396-397
    • Jones, B.M.1    O'Brien, C.J.2
  • 23
    • 0029129427 scopus 로고
    • Hand ischemia in patients with hemodialysis access grafts: angiographic diagnosis and treatment
    • Valji K, Hye RJ, Roberts AC, et al. Hand ischemia in patients with hemodialysis access grafts: angiographic diagnosis and treatment. Radiology 1995;196:697-701
    • (1995) Radiology , vol.196 , pp. 697-701
    • Valji, K.1    Hye, R.J.2    Roberts, A.C.3
  • 24
    • 0039191565 scopus 로고    scopus 로고
    • Surgical implications of variations in hand collateral circulation: Anatomy revisited
    • Ruengsakulrach P, Eizenberg N, Fahrer C, et al. Surgical implications of variations in hand collateral circulation: Anatomy revisited. J Thorac Cardiovasc Surg 2001;122:682-686
    • (2001) J Thorac Cardiovasc Surg , vol.122 , pp. 682-686
    • Ruengsakulrach, P.1    Eizenberg, N.2    Fahrer, C.3
  • 25
    • 0037349230 scopus 로고    scopus 로고
    • Complications after radial artery harvesting for coronary artery bypass grafting: our experience
    • Budillon AM, Nicolini F, Agostinelli A, et al. Complications after radial artery harvesting for coronary artery bypass grafting: our experience. Surgery 2003;133:283-287
    • (2003) Surgery , vol.133 , pp. 283-287
    • Budillon, A.M.1    Nicolini, F.2    Agostinelli, A.3
  • 26
    • 0035168452 scopus 로고    scopus 로고
    • Functional status of the hand after radial artery harvesting: results in 3977 cases
    • Meharwal ZS, Trehan N. Functional status of the hand after radial artery harvesting: results in 3977 cases. Ann Thorac Surg 2001;72:1557-1561
    • (2001) Ann Thorac Surg , vol.72 , pp. 1557-1561
    • Meharwal, Z.S.1    Trehan, N.2
  • 27
    • 0036731770 scopus 로고    scopus 로고
    • Post radial artery harvest hand perception: postoperative 12-month follow-up results
    • Hata M, Raman J, Seevanayagam S, et al. Post radial artery harvest hand perception: postoperative 12-month follow-up results. Circ J 2002;66:816-818
    • (2002) Circ J , vol.66 , pp. 816-818
    • Hata, M.1    Raman, J.2    Seevanayagam, S.3
  • 28
    • 0035110159 scopus 로고    scopus 로고
    • Does routine use of the radial artery increase complexity or morbidity of coronary bypass surgery?
    • Anyanwu AC, Saeed I, Bustani M, et al. Does routine use of the radial artery increase complexity or morbidity of coronary bypass surgery? Ann Thorac Surg 2001;71:555-560
    • (2001) Ann Thorac Surg , vol.71 , pp. 555-560
    • Anyanwu, A.C.1    Saeed, I.2    Bustani, M.3
  • 29
    • 2542437670 scopus 로고    scopus 로고
    • Oxygen pressure measurement during grip exercise reveals exercise intolerance after radial harvest
    • Manabe S, Tabuchi N, Toyama M, et al. Oxygen pressure measurement during grip exercise reveals exercise intolerance after radial harvest. Ann Thorac Surg 2004;77:2066-2070
    • (2004) Ann Thorac Surg , vol.77 , pp. 2066-2070
    • Manabe, S.1    Tabuchi, N.2    Toyama, M.3
  • 30
    • 3242742801 scopus 로고    scopus 로고
    • Harvest of the radial artery for coronary artery surgery preserves maximal blood flow of the forearm
    • Royse AG, Royse CF, Maleskar A, et al. Harvest of the radial artery for coronary artery surgery preserves maximal blood flow of the forearm. Ann Thorac Surg 2004;78:539-542
    • (2004) Ann Thorac Surg , vol.78 , pp. 539-542
    • Royse, A.G.1    Royse, C.F.2    Maleskar, A.3
  • 31
    • 0037384030 scopus 로고    scopus 로고
    • Effects of radial artery harvesting on forearm function and blood flow
    • Chong WC, Ong PJL, Hayward CS, et al. Effects of radial artery harvesting on forearm function and blood flow. Ann Thorac Surg 2003;75:1171-1174
    • (2003) Ann Thorac Surg , vol.75 , pp. 1171-1174
    • Chong, W.C.1    Ong, P.J.L.2    Hayward, C.S.3
  • 32
    • 33645232818 scopus 로고    scopus 로고
    • Forearm problems after CABG using radial artery grafts
    • (in Japanese, English abstract)
    • Nakamura K, Hata T, Tsushima M, et al. Forearm problems after CABG using radial artery grafts. (in Japanese, English abstract). Jpn J Cardiovasc Surg 2000;29:368-372
    • (2000) Jpn J Cardiovasc Surg , vol.29 , pp. 368-372
    • Nakamura, K.1    Hata, T.2    Tsushima, M.3
  • 33
    • 0032588101 scopus 로고    scopus 로고
    • No change in O2 satu-ration but measurable difference in thenar flexor power after radial artery harvest
    • Grossebner M, Arifi A, Bourov Y, et al. No change in O2 saturation but measurable difference in thenar flexor power after radial artery harvest. Eur J Cardiovasc Surg 1999;16:160-162.
    • (1999) Eur J Cardiovasc Surg , vol.16 , pp. 160-162
    • Grossebner, M.1    Arifi, A.2    Bourov, Y.3
  • 34
    • 0033979506 scopus 로고    scopus 로고
    • Upper extremity hemodynamic changes after radial artery harvest for coronary artery bypass grafting
    • Lohr JM, Paget DS, Smith M, et al. Upper extremity hemodynamic changes after radial artery harvest for coronary artery bypass grafting. Ann Vasc Surg 2000;14:56-62
    • (2000) Ann Vasc Surg , vol.14 , pp. 56-62
    • Lohr, J.M.1    Paget, D.S.2    Smith, M.3
  • 35
    • 2542483415 scopus 로고    scopus 로고
    • Digital blood flow after radial artery harvest for coronary artery bypass grafting
    • Lee HS, Chang BC, Heo YJ. Digital blood flow after radial artery harvest for coronary artery bypass grafting. Ann Thorac Surg 2004;77:2071-2075
    • (2004) Ann Thorac Surg , vol.77 , pp. 2071-2075
    • Lee, H.S.1    Chang, B.C.2    Heo, Y.J.3
  • 36
    • 0032723088 scopus 로고    scopus 로고
    • Hemodynamic and functional consequences of radial artery removal for coronary artery bypass grafting
    • Serricchio M, Gaudino M, Tondi P, et al. Hemodynamic and functional consequences of radial artery removal for coronary artery bypass grafting. Am J Cardiol 1999;84:1353-1356
    • (1999) Am J Cardiol , vol.84 , pp. 1353-1356
    • Serricchio, M.1    Gaudino, M.2    Tondi, P.3
  • 37
    • 85005877159 scopus 로고    scopus 로고
    • Effect of radial artery harvesting on tissue perfusion and function of the hand
    • Sadaba JR, Conroy JL, Burniston M, et al. Effect of radial artery harvesting on tissue perfusion and function of the hand. Cardiovasc Surg 2001;9:378-382
    • (2001) Cardiovasc Surg , vol.9 , pp. 378-382
    • Sadaba, J.R.1    Conroy, J.L.2    Burniston, M.3
  • 38
    • 33645219939 scopus 로고    scopus 로고
    • Clinical and thermographic findings in the late postoperative period after coronary artery bypass surgery using the radial artery
    • (in Japanese, English abstract)
    • Takahashi S, Sadahiro M, Yamaya K, et al. Clinical and thermographic findings in the late postoperative period after coronary artery bypass surgery using the radial artery. (in Japanese, English abstract). Jpn J Cardiovasc Surg 2003;32:220-223
    • (2003) Jpn J Cardiovasc Surg , vol.32 , pp. 220-223
    • Takahashi, S.1    Sadahiro, M.2    Yamaya, K.3
  • 39
    • 11144283170 scopus 로고    scopus 로고
    • Long-term digital blood flow after radial artery harvesting for coronary artery bypass grafting
    • Lee HS, Heo YJ, Chang BC. Long-term digital blood flow after radial artery harvesting for coronary artery bypass grafting. Eur J Cardiothoracic Surg 2005;27:99-103
    • (2005) Eur J Cardiothoracic Surg , vol.27 , pp. 99-103
    • Lee, H.S.1    Heo, Y.J.2    Chang, B.C.3
  • 40
    • 1642441585 scopus 로고    scopus 로고
    • Duplex ultrasonography predicts safety of radial artery harvest in the presence of an abnormal Allen test
    • Abu-Omar Y, Mussa S, Anastasiadis K, et al. Duplex ultrasonography predicts safety of radial artery harvest in the presence of an abnormal Allen test. Ann Thorac Surg 2004;77:116-119
    • (2004) Ann Thorac Surg , vol.77 , pp. 116-119
    • Abu-Omar, Y.1    Mussa, S.2    Anastasiadis, K.3
  • 41
    • 0031727689 scopus 로고    scopus 로고
    • The radial artery for coronary artery bypass grafting: clinical and angiographic results at five years
    • Acar C, Ramsheyi A, Pagny JY, et al. The radial artery for coronary artery bypass grafting: clinical and angiographic results at five years. J Thorac Cardiovasc Surg 1998;116:981-989
    • (1998) J Thorac Cardiovasc Surg , vol.116 , pp. 981-989
    • Acar, C.1    Ramsheyi, A.2    Pagny, J.Y.3
  • 42
    • 0029063727 scopus 로고
    • Radial artery graft for coronary revascularization: Technical considerations
    • Dietl CA, Benoit CH. Radial artery graft for coronary revascularization: Technical considerations. Ann Thorac Surg 1995;60:102-110
    • (1995) Ann Thorac Surg , vol.60 , pp. 102-110
    • Dietl, C.A.1    Benoit, C.H.2
  • 43
    • 0036118768 scopus 로고    scopus 로고
    • The radial hyperaemic response: a new and objective assessment of ulnar collateral supply to the hand
    • Roberts N, Ghosh S, Boehm M, et al. The radial hyperaemic response: a new and objective assessment of ulnar collateral supply to the hand. Eur J Cardiothorac Surg 2002;21:549-552.
    • (2002) Eur J Cardiothorac Surg , vol.21 , pp. 549-552
    • Roberts, N.1    Ghosh, S.2    Boehm, M.3
  • 44
    • 0019313406 scopus 로고
    • False positive and negative results in Allen test
    • Hirai M, Kawai S. False positive and negative results in Allen test. J Cardiovasc Surg 1980;21:353-360
    • (1980) J Cardiovasc Surg , vol.21 , pp. 353-360
    • Hirai, M.1    Kawai, S.2
  • 45
    • 0035412831 scopus 로고    scopus 로고
    • Anatomic assessment of hand circulation in harvesting the radial artery
    • Ruengsakulrach P, Buxton BF, Eizenberg N, et al. Anatomic assessment of hand circulation in harvesting the radial artery. J Thorac Cardiovasc Surg 2001;122:178-180
    • (2001) J Thorac Cardiovasc Surg , vol.122 , pp. 178-180
    • Ruengsakulrach, P.1    Buxton, B.F.2    Eizenberg, N.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.