-
1
-
-
0036267186
-
Toward direct mapping of neuronal activity: MRI detection of ultraweak, transient magnetic field changes
-
Bodurka J, Bandiettini PA. Toward direct mapping of neuronal activity: MRI detection of ultraweak, transient magnetic field changes. Magn Reson Med 2002; 47:1052-1058.
-
(2002)
Magn Reson Med
, vol.47
, pp. 1052-1058
-
-
Bodurka, J.1
Bandiettini, P.A.2
-
2
-
-
0042329673
-
Directly mapping magnetic field effects of neuronal activity by magnetic resonance imaging
-
Xiong J, Fox PT, Gao JH. Directly mapping magnetic field effects of neuronal activity by magnetic resonance imaging. Hum Brain Mapp 2003; 20:41-49.
-
(2003)
Hum Brain Mapp
, vol.20
, pp. 41-49
-
-
Xiong, J.1
Fox, P.T.2
Gao, J.H.3
-
3
-
-
0038601502
-
MRI detection of weak magnetic fields due to an extended current dipole in a conducting sphere: A model for direct detection of neuronal currents in the brain
-
Konn D, Gowland P, Bowtell R. MRI detection of weak magnetic fields due to an extended current dipole in a conducting sphere: a model for direct detection of neuronal currents in the brain. Magn Reson Med 2003; 50:40-49.
-
(2003)
Magn Reson Med
, vol.50
, pp. 40-49
-
-
Konn, D.1
Gowland, P.2
Bowtell, R.3
-
4
-
-
0033183986
-
Neuronal current distribution imaging using magnetic resonance
-
Kamei H, Iramina K, Yoshikawa K, Ueno S. Neuronal current distribution imaging using magnetic resonance. IEEE Trans Magn 1999; 35: 4109-4111.
-
(1999)
IEEE Trans Magn
, vol.35
, pp. 4109-4111
-
-
Kamei, H.1
Iramina, K.2
Yoshikawa, K.3
Ueno, S.4
-
5
-
-
84887829641
-
FEM-based calculation of the theoretical limit of sensitivity for detecting weak magnetic fields in the human brain using magnetic resonance imaging
-
(in press)
-
Hatada T, Sekino M, Ueno S. FEM-based calculation of the theoretical limit of sensitivity for detecting weak magnetic fields in the human brain using magnetic resonance imaging. J Appl Phys (in press).
-
J Appl Phys
-
-
Hatada, T.1
Sekino, M.2
Ueno, S.3
-
7
-
-
49549133678
-
The signal-to-noise ratio of the nuclear magnetic resonance experiment
-
Hoult DI, Richards RE. The signal-to-noise ratio of the nuclear magnetic resonance experiment. J Magn Reson 1976; 24:71-85.
-
(1976)
J Magn Reson
, vol.24
, pp. 71-85
-
-
Hoult, D.I.1
Richards, R.E.2
-
8
-
-
0000178929
-
Sensitivity and resolution in NMR imaging
-
Callaghan PT, Eccles CD. Sensitivity and resolution in NMR imaging. J Magn Reson 1987; 71: 426-445.
-
(1987)
J Magn Reson
, vol.71
, pp. 426-445
-
-
Callaghan, P.T.1
Eccles, C.D.2
-
9
-
-
0000132799
-
The sensitivity of the zeugmatographic experiment involving human samples
-
Hoult DI, Lauterbur PC. The sensitivity of the zeugmatographic experiment involving human samples. J Magn Reson 1979; 34:425-433.
-
(1979)
J Magn Reson
, vol.34
, pp. 425-433
-
-
Hoult, D.I.1
Lauterbur, P.C.2
-
10
-
-
34250079729
-
The NMR sensitivity achievable with a slotted-tube resonator
-
Iriguchi N, Yamai S, Hasegawa J. The NMR sensitivity achievable with a slotted-tube resonator. MAGMA 1993; 1:122-125.
-
(1993)
MAGMA
, vol.1
, pp. 122-125
-
-
Iriguchi, N.1
Yamai, S.2
Hasegawa, J.3
|