메뉴 건너뛰기




Volumn 46, Issue 8, 2005, Pages 1434-1445

Distal myocardial protection during percutaneous coronary intervention: When and where?

Author keywords

[No Author keywords available]

Indexed keywords

ABCIXIMAB; FIBRINOGEN RECEPTOR ANTAGONIST; TIROFIBAN;

EID: 26844569531     PISSN: 07351097     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jacc.2005.04.061     Document Type: Review
Times cited : (45)

References (42)
  • 1
    • 0025061962 scopus 로고
    • New triple coaxial catheter system for carotid angioplasty with cerebral protection
    • J. Theron, P. Courtheoux, F. Alachkar, G. Bouvard, D. Maiza New triple coaxial catheter system for carotid angioplasty with cerebral protection Am J Neuroradiol 11 1990 869 874
    • (1990) Am J Neuroradiol , vol.11 , pp. 869-874
    • Theron, J.1    Courtheoux, P.2    Alachkar, F.3    Bouvard, G.4    Maiza, D.5
  • 2
    • 10744222252 scopus 로고    scopus 로고
    • Routine use of cerebral protection during carotid artery stenting: Results of a multicenter registry of 753 patients
    • B. Reimers, M. Schluter, F. Castriota Routine use of cerebral protection during carotid artery stenting results of a multicenter registry of 753 patients Am J Med 116 2004 217 222
    • (2004) Am J Med , vol.116 , pp. 217-222
    • Reimers, B.1    Schluter, M.2    Castriota, F.3
  • 4
    • 0036629702 scopus 로고    scopus 로고
    • Incidence and clinical significance of distal embolization during primary angioplasty for acute myocardial infarction
    • J.P. Henriques, F. Zijlstra, J.P. Ottervanger Incidence and clinical significance of distal embolization during primary angioplasty for acute myocardial infarction Eur Heart J 23 2002 1112 1117
    • (2002) Eur Heart J , vol.23 , pp. 1112-1117
    • Henriques, J.P.1    Zijlstra, F.2    Ottervanger, J.P.3
  • 5
    • 26844491402 scopus 로고    scopus 로고
    • EMERALD: Enhanced Myocardial Efficacy and Removal by Aspiration of Liberated Debris
    • Stone GW. EMERALD: Enhanced Myocardial Efficacy and Removal by Aspiration of Liberated Debris. Presented at The American College of Cardiology Annual Scientific Session 2004. Available at: http://www.medscape.com/viewarticle/ 471880. Accessed August 2, 2005
    • American College of Cardiology Annual Scientific Session 2004
    • Stone, G.W.1
  • 6
    • 0038785539 scopus 로고    scopus 로고
    • Mechanical prevention of distal embolization during primary angioplasty: Safety, feasibility, and impact on myocardial reperfusion
    • U. Limbruno, A. Micheli, M. De Carlo Mechanical prevention of distal embolization during primary angioplasty safety, feasibility, and impact on myocardial reperfusion Circulation 108 2003 171 176
    • (2003) Circulation , vol.108 , pp. 171-176
    • Limbruno, U.1    Micheli, A.2    De Carlo, M.3
  • 7
    • 0035856529 scopus 로고    scopus 로고
    • Prevention of distal embolization during coronary angioplasty in saphenous vein grafts and native vessels using porous filter protection
    • E. Grube, U. Gerckens, A.C. Yeung Prevention of distal embolization during coronary angioplasty in saphenous vein grafts and native vessels using porous filter protection Circulation 104 2001 2436 2441
    • (2001) Circulation , vol.104 , pp. 2436-2441
    • Grube, E.1    Gerckens, U.2    Yeung, A.C.3
  • 8
    • 0036792761 scopus 로고    scopus 로고
    • Initial clinical experience with distal protection using the FilterWire in patients undergoing coronary artery and saphenous vein graft percutaneous intervention
    • J.J. Popma, N. Cox, K.E. Hauptmann Initial clinical experience with distal protection using the FilterWire in patients undergoing coronary artery and saphenous vein graft percutaneous intervention Catheter Cardiovasc Interv 57 2002 125 134
    • (2002) Catheter Cardiovasc Interv , vol.57 , pp. 125-134
    • Popma, J.J.1    Cox, N.2    Hauptmann, K.E.3
  • 10
    • 0038827441 scopus 로고    scopus 로고
    • Carotid angioplasty in a pulsatile flow model: Factors affecting embolic potential
    • C.D. Bicknell, M.G. Cowling, M.W. Clark Carotid angioplasty in a pulsatile flow model factors affecting embolic potential Eur J Vasc Endovasc Surg 26 2003 22 31
    • (2003) Eur J Vasc Endovasc Surg , vol.26 , pp. 22-31
    • Bicknell, C.D.1    Cowling, M.G.2    Clark, M.W.3
  • 11
    • 0038827438 scopus 로고    scopus 로고
    • The relationship between carotid atherosclerotic plaque morphology and the embolic risk during endovascular therapy
    • C.D. Bicknell, N.J. Cheshire The relationship between carotid atherosclerotic plaque morphology and the embolic risk during endovascular therapy Eur J Vasc Endovasc Surg 26 2003 17 21
    • (2003) Eur J Vasc Endovasc Surg , vol.26 , pp. 17-21
    • Bicknell, C.D.1    Cheshire, N.J.2
  • 12
    • 0029938354 scopus 로고    scopus 로고
    • Angioscopic predictors of early adverse outcome after coronary angioplasty in patients with unstable angina and non-Q-wave myocardial infarction
    • S. Waxman, M.A. Sassower, M.A. Mittleman Angioscopic predictors of early adverse outcome after coronary angioplasty in patients with unstable angina and non-Q-wave myocardial infarction Circulation 93 1996 2106 2113
    • (1996) Circulation , vol.93 , pp. 2106-2113
    • Waxman, S.1    Sassower, M.A.2    Mittleman, M.A.3
  • 13
    • 0029069590 scopus 로고
    • Plaque ulceration and lumen thrombus are the main sources of cerebral microemboli in high-grade internal carotid artery stenosis
    • M. Sitzer, W. Muller, M. Siebler Plaque ulceration and lumen thrombus are the main sources of cerebral microemboli in high-grade internal carotid artery stenosis Stroke 26 1995 1231 1233
    • (1995) Stroke , vol.26 , pp. 1231-1233
    • Sitzer, M.1    Muller, W.2    Siebler, M.3
  • 14
    • 4143116831 scopus 로고    scopus 로고
    • Relationship of matrix metalloproteinases and macrophages to embolization during endoluminal carotid interventions
    • C.D. Bicknell, D. Peck, N.A. Alkhamesi Relationship of matrix metalloproteinases and macrophages to embolization during endoluminal carotid interventions J Endovasc Ther 11 2004 483 493
    • (2004) J Endovasc Ther , vol.11 , pp. 483-493
    • Bicknell, C.D.1    Peck, D.2    Alkhamesi, N.A.3
  • 15
    • 0024848058 scopus 로고
    • Progressive impairment of regional myocardial perfusion after initial restoration of postischemic blood flow
    • G. Ambrosio, H.F. Weisman, J.A. Mannisi, L.C. Becker Progressive impairment of regional myocardial perfusion after initial restoration of postischemic blood flow Circulation 80 1989 1846 1861
    • (1989) Circulation , vol.80 , pp. 1846-1861
    • Ambrosio, G.1    Weisman, H.F.2    Mannisi, J.A.3    Becker, L.C.4
  • 16
    • 0016315064 scopus 로고
    • The "no-reflow" phenomenon after temporary coronary occlusion in the dog
    • R.A. Kloner, C.E. Ganote, R.B. Jennings The "no-reflow" phenomenon after temporary coronary occlusion in the dog J Clin Invest 54 1974 1496 1508
    • (1974) J Clin Invest , vol.54 , pp. 1496-1508
    • Kloner, R.A.1    Ganote, C.E.2    Jennings, R.B.3
  • 17
    • 0027516113 scopus 로고
    • Platelet and neutrophil imaging techniques in the investigation of the response to thrombolytic therapy and the no-reflow phenomenon
    • C. Seydoux, J.J. Goy, G. Davies Platelet and neutrophil imaging techniques in the investigation of the response to thrombolytic therapy and the no-reflow phenomenon Am Heart J 125 1993 1142 1147
    • (1993) Am Heart J , vol.125 , pp. 1142-1147
    • Seydoux, C.1    Goy, J.J.2    Davies, G.3
  • 18
    • 0026719365 scopus 로고
    • Complete prevention of myocardial stunning, contracture, low-reflow, and edema after heart transplantation by blocking neutrophil adhesion molecules during reperfusion
    • J.G. Byrne, W.J. Smith, M.P. Murphy, G.S. Couper, R.F. Appleyard, L.H. Cohn Complete prevention of myocardial stunning, contracture, low-reflow, and edema after heart transplantation by blocking neutrophil adhesion molecules during reperfusion J Thorac Cardiovasc Surg 104 1992 1589 1596
    • (1992) J Thorac Cardiovasc Surg , vol.104 , pp. 1589-1596
    • Byrne, J.G.1    Smith, W.J.2    Murphy, M.P.3    Couper, G.S.4    Appleyard, R.F.5    Cohn, L.H.6
  • 19
    • 0026507292 scopus 로고
    • Reperfusion of hibernating myocardium: Contractile function, high-energy phosphate content, and myocyte injury after 3 hours of sublethal ischemia and 3 hours of reperfusion in the canine model
    • K. Przyklenk, B. Bauer, R.A. Kloner Reperfusion of hibernating myocardium contractile function, high-energy phosphate content, and myocyte injury after 3 hours of sublethal ischemia and 3 hours of reperfusion in the canine model Am Heart J 123 1992 575 588
    • (1992) Am Heart J , vol.123 , pp. 575-588
    • Przyklenk, K.1    Bauer, B.2    Kloner, R.A.3
  • 20
    • 10744230885 scopus 로고    scopus 로고
    • Effect of the PercuSurge GuardWire device on the integrity of microvasculature and clinical outcomes during primary transradial coronary intervention in acute myocardial infarction
    • H.K. Yip, C.J. Wu, H.W. Chang Effect of the PercuSurge GuardWire device on the integrity of microvasculature and clinical outcomes during primary transradial coronary intervention in acute myocardial infarction Am J Cardiol 92 2003 1331 1335
    • (2003) Am J Cardiol , vol.92 , pp. 1331-1335
    • Yip, H.K.1    Wu, C.J.2    Chang, H.W.3
  • 21
    • 0037150152 scopus 로고    scopus 로고
    • Intracoronary thrombectomy with the X-sizer catheter system improves epicardial flow and accelerates ST-segment resolution in patients with acute coronary syndrome: A prospective, randomized, controlled study
    • G. Beran, I. Lang, W. Schreiber Intracoronary thrombectomy with the X-sizer catheter system improves epicardial flow and accelerates ST-segment resolution in patients with acute coronary syndrome a prospective, randomized, controlled study Circulation 105 2002 2355 2360
    • (2002) Circulation , vol.105 , pp. 2355-2360
    • Beran, G.1    Lang, I.2    Schreiber, W.3
  • 22
    • 0142107365 scopus 로고    scopus 로고
    • Intracoronary thrombectomy improves myocardial reperfusion in patients undergoing direct angioplasty for acute myocardial infarction
    • M. Napodano, G. Pasquetto, S. Sacca Intracoronary thrombectomy improves myocardial reperfusion in patients undergoing direct angioplasty for acute myocardial infarction J Am Coll Cardiol 42 2003 1395 1402
    • (2003) J Am Coll Cardiol , vol.42 , pp. 1395-1402
    • Napodano, M.1    Pasquetto, G.2    Sacca, S.3
  • 23
    • 0036467897 scopus 로고    scopus 로고
    • A trial comparing rheolytic thrombectomy with intracoronary urokinase for coronary and vein graft thrombus (the Vein Graft AngioJet Study [VeGAS 2])
    • R.E. Kuntz, D.S. Baim, D.J. Cohen A trial comparing rheolytic thrombectomy with intracoronary urokinase for coronary and vein graft thrombus (the Vein Graft AngioJet Study [VeGAS 2]) Am J Cardiol 89 2002 326 330
    • (2002) Am J Cardiol , vol.89 , pp. 326-330
    • Kuntz, R.E.1    Baim, D.S.2    Cohen, D.J.3
  • 24
    • 0028845854 scopus 로고
    • Angioplasty of complex lesions in ischemic rest angina: Results of the Thrombolysis and Angioplasty in Unstable Angina (TAUSA) trial
    • R. Mehran, J.A. Ambrose, R.M. Bongu Angioplasty of complex lesions in ischemic rest angina results of the Thrombolysis and Angioplasty in Unstable Angina (TAUSA) trial J Am Coll Cardiol 26 1995 961 966
    • (1995) J Am Coll Cardiol , vol.26 , pp. 961-966
    • Mehran, R.1    Ambrose, J.A.2    Bongu, R.M.3
  • 25
    • 0028232692 scopus 로고
    • Incidence and treatment of 'no-reflow' after percutaneous coronary intervention
    • R.N. Piana, G.Y. Paik, M. Moscucci Incidence and treatment of 'no-reflow' after percutaneous coronary intervention Circulation 89 1994 2514 2518
    • (1994) Circulation , vol.89 , pp. 2514-2518
    • Piana, R.N.1    Paik, G.Y.2    Moscucci, M.3
  • 26
    • 0032533589 scopus 로고    scopus 로고
    • Reduction in complications of angioplasty with abciximab occurs largely independently of baseline lesion morphology. EPIC and EPILOG Investigators. Evaluation of 7E3 for the Prevention of Ischemic Complications. Evaluation of PTCA to Improve Long-term Outcome with abciximab GP IIb/IIIa Receptor Blockade
    • S.G. Ellis, A.M. Lincoff, D. Miller Reduction in complications of angioplasty with abciximab occurs largely independently of baseline lesion morphology. EPIC and EPILOG Investigators. Evaluation of 7E3 for the Prevention of Ischemic Complications. Evaluation of PTCA To Improve Long-term Outcome with abciximab GP IIb/IIIa Receptor Blockade J Am Coll Cardiol 32 1998 1619 1623
    • (1998) J Am Coll Cardiol , vol.32 , pp. 1619-1623
    • Ellis, S.G.1    Lincoff, A.M.2    Miller, D.3
  • 27
    • 0033213390 scopus 로고    scopus 로고
    • The influence of abciximab use on clinical outcome after aortocoronary vein graft interventions
    • V. Mathew, D.E. Grill, C.G. Scott The influence of abciximab use on clinical outcome after aortocoronary vein graft interventions J Am Coll Cardiol 34 1999 1163 1169
    • (1999) J Am Coll Cardiol , vol.34 , pp. 1163-1169
    • Mathew, V.1    Grill, D.E.2    Scott, C.G.3
  • 28
    • 0025831602 scopus 로고
    • Differential histopathology of primary atherosclerotic and restenotic lesions in coronary arteries and saphenous vein bypass grafts: Analysis of tissue obtained from 73 patients by directional atherectomy
    • K.N. Garratt, W.D. Edwards, U.P. Kaufmann, R.E. Vlietstra, D.R. Holmes Jr Differential histopathology of primary atherosclerotic and restenotic lesions in coronary arteries and saphenous vein bypass grafts analysis of tissue obtained from 73 patients by directional atherectomy J Am Coll Cardiol 17 1991 442 448
    • (1991) J Am Coll Cardiol , vol.17 , pp. 442-448
    • Garratt, K.N.1    Edwards, W.D.2    Kaufmann, U.P.3    Vlietstra, R.E.4    Holmes Jr., D.R.5
  • 29
    • 0037090549 scopus 로고    scopus 로고
    • Evaluation of a balloon occlusion and aspiration system for protection from distal embolization during stenting in saphenous vein grafts
    • E. Grube, J.J. Schofer, J. Webb Evaluation of a balloon occlusion and aspiration system for protection from distal embolization during stenting in saphenous vein grafts Am J Cardiol 89 2002 941 945
    • (2002) Am J Cardiol , vol.89 , pp. 941-945
    • Grube, E.1    Schofer, J.J.2    Webb, J.3
  • 30
    • 0032786887 scopus 로고    scopus 로고
    • Creatine kinase-MB enzyme elevation following successful saphenous vein graft intervention is associated with late mortality
    • M.K. Hong, R. Mehran, G. Dangas Creatine kinase-MB enzyme elevation following successful saphenous vein graft intervention is associated with late mortality Circulation 100 1999 2400 2405
    • (1999) Circulation , vol.100 , pp. 2400-2405
    • Hong, M.K.1    Mehran, R.2    Dangas, G.3
  • 31
    • 0037133682 scopus 로고    scopus 로고
    • Randomized trial of a distal embolic protection device during percutaneous intervention of saphenous vein aorto-coronary bypass grafts
    • D.S. Baim, D. Wahr, B. George Randomized trial of a distal embolic protection device during percutaneous intervention of saphenous vein aorto-coronary bypass grafts Circulation 105 2002 1285 1290
    • (2002) Circulation , vol.105 , pp. 1285-1290
    • Baim, D.S.1    Wahr, D.2    George, B.3
  • 32
    • 0037145803 scopus 로고    scopus 로고
    • Distal filter protection during saphenous vein graft stenting: Technical and clinical correlates of efficacy
    • G.W. Stone, C. Rogers, S. Ramee Distal filter protection during saphenous vein graft stenting technical and clinical correlates of efficacy J Am Coll Cardiol 40 2002 1882 1888
    • (2002) J Am Coll Cardiol , vol.40 , pp. 1882-1888
    • Stone, G.W.1    Rogers, C.2    Ramee, S.3
  • 33
    • 0043075814 scopus 로고    scopus 로고
    • Randomized comparison of distal protection with a filter-based catheter and a balloon occlusion and aspiration system during percutaneous intervention of diseased saphenous vein aorto-coronary bypass grafts
    • G.W. Stone, C. Rogers, J. Hermiller Randomized comparison of distal protection with a filter-based catheter and a balloon occlusion and aspiration system during percutaneous intervention of diseased saphenous vein aorto-coronary bypass grafts Circulation 108 2003 548 553
    • (2003) Circulation , vol.108 , pp. 548-553
    • Stone, G.W.1    Rogers, C.2    Hermiller, J.3
  • 34
    • 7044224467 scopus 로고    scopus 로고
    • Effectiveness and safety of the Proxis system in demonstrating retrograde coronary blood flow during proximal occlusion and in capturing embolic material
    • H. Sievert, D.W. Wahr, G. Schuler Effectiveness and safety of the Proxis system in demonstrating retrograde coronary blood flow during proximal occlusion and in capturing embolic material Am J Cardiol 94 2004 1134 1139
    • (2004) Am J Cardiol , vol.94 , pp. 1134-1139
    • Sievert, H.1    Wahr, D.W.2    Schuler, G.3
  • 35
    • 20244366329 scopus 로고    scopus 로고
    • Prospective, randomized evaluation of thrombectomy prior to percutaneous intervention in diseased saphenous vein grafts and thrombus-containing coronary arteries
    • G.W. Stone, D.A. Cox, J. Babb Prospective, randomized evaluation of thrombectomy prior to percutaneous intervention in diseased saphenous vein grafts and thrombus-containing coronary arteries J Am Coll Cardiol 42 2003 2007 2013
    • (2003) J Am Coll Cardiol , vol.42 , pp. 2007-2013
    • Stone, G.W.1    Cox, D.A.2    Babb, J.3
  • 36
    • 0034019453 scopus 로고    scopus 로고
    • Embolic risk of the different stages of carotid bifurcation balloon angioplasty: An experimental study
    • M. Coggia, O. Goeau-Brissonniere, J.L. Duval, J.P. Leschi, M. Letort, M.D. Nagel Embolic risk of the different stages of carotid bifurcation balloon angioplasty an experimental study J Vasc Surg 31 2000 550 557
    • (2000) J Vasc Surg , vol.31 , pp. 550-557
    • Coggia, M.1    Goeau-Brissonniere, O.2    Duval, J.L.3    Leschi, J.P.4    Letort, M.5    Nagel, M.D.6
  • 37
    • 0036937995 scopus 로고    scopus 로고
    • Microembolization during carotid stenting with the distal-balloon antiemboli system
    • N. Al Mubarak, G.S. Roubin, J.J. Vitek, S.S. Iyer Microembolization during carotid stenting with the distal-balloon antiemboli system Int Angiol 21 2002 344 348
    • (2002) Int Angiol , vol.21 , pp. 344-348
    • Al Mubarak, N.1    Roubin, G.S.2    Vitek, J.J.3    Iyer, S.S.4
  • 38
    • 0035940384 scopus 로고    scopus 로고
    • Effect of the distal-balloon protection system on microembolization during carotid stenting
    • N. Al Mubarak, G.S. Roubin, J.J. Vitek, S.S. Iyer, G. New, M.B. Leon Effect of the distal-balloon protection system on microembolization during carotid stenting Circulation 104 2001 1999 2002
    • (2001) Circulation , vol.104 , pp. 1999-2002
    • Al Mubarak, N.1    Roubin, G.S.2    Vitek, J.J.3    Iyer, S.S.4    New, G.5    Leon, M.B.6
  • 39
    • 0035808012 scopus 로고    scopus 로고
    • Balloon-protected carotid artery stenting: Relationship of periprocedural neurological complications with the size of particulate debris
    • T. Tubler, M. Schluter, O. Dirsch Balloon-protected carotid artery stenting relationship of periprocedural neurological complications with the size of particulate debris Circulation 104 2001 2791 2796
    • (2001) Circulation , vol.104 , pp. 2791-2796
    • Tubler, T.1    Schluter, M.2    Dirsch, O.3
  • 40
    • 1542347781 scopus 로고    scopus 로고
    • Safety and feasibility of the use of a distal filter protection device in percutaneous revascularization of small coronary arteries
    • W.H. Chen, P.Y. Lee, W. Ng, C.P. Lau Safety and feasibility of the use of a distal filter protection device in percutaneous revascularization of small coronary arteries Catheter Cardiovasc Interv 61 2004 360 363
    • (2004) Catheter Cardiovasc Interv , vol.61 , pp. 360-363
    • Chen, W.H.1    Lee, P.Y.2    Ng, W.3    Lau, C.P.4
  • 41
    • 0036093197 scopus 로고    scopus 로고
    • Carotid artery stenting protected with an emboli containment system
    • P.L. Whitlow, P. Lylyk, H. Londero Carotid artery stenting protected with an emboli containment system Stroke 33 2002 1308 1314
    • (2002) Stroke , vol.33 , pp. 1308-1314
    • Whitlow, P.L.1    Lylyk, P.2    Londero, H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.